摘要
In recent years radiation risk from CT scanning has become an important area of investigation. Many authors have suggested that radiation dose can be decreased without loss of diagnostic information. This dose reduction has primarily been achieved through a decrease in tube current. An area that has received little attention has been variations in dose from different CT scanners. To evaluate this aspect of radiation exposure, we measured the radiation dose of 4 different CT scanners. We found that the radiation dose for the same CT technique can vary by as much as a factor of 3 when I mm slices are used. CT dose variation was greatest for thin slices, making these observations particularly important for high-resolution CT. Our measurement technique used standard quality assurance equipment available in most radiology departments. Use of these measurements to assess the radiation dose from different CT scanners is an easily performed technique that may allow a decrease in radiation exposure in departments by choosing the most appropriate intradepartmental CT scanner for specific indications.
引用
收藏
页码:242 / 245
页数:4
相关论文
共 14 条
[1]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[2]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[3]   Effective doses to patients undergoing thoracic computed tomography examinations [J].
Huda, W ;
Scalzetti, EM ;
Roskopf, M .
MEDICAL PHYSICS, 2000, 27 (05) :838-844
[4]  
*INT EL COMM, 1999, INT EL COMM PUBL
[5]   Low-dose high-resolution CT of the chest in children and young adults:: Dose, cooperation, artifact incidence, and image quality [J].
Lucaya, J ;
Piqueras, J ;
García-Peña, P ;
Enríquez, G ;
García-Macías, M ;
Sotil, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) :985-992
[6]   Original report - Dose and pitch relationship for a particular multislice CT scanner [J].
Mahesh, M ;
Scatarige, JC ;
Cooper, J ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1273-1275
[7]   HIGH-RESOLUTION CT OF THE LUNGS - AN OPTIMAL APPROACH [J].
MAYO, JR ;
WEBB, WR ;
GOULD, R ;
STEIN, MG ;
BASS, I ;
GAMSU, G ;
GOLDBERG, HI .
RADIOLOGY, 1987, 163 (02) :507-510
[8]   HIGH-RESOLUTION CT OF THE CHEST - RADIATION-DOSE [J].
MAYO, JR ;
JACKSON, SA ;
MULLER, NL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :479-481
[9]   Performance evaluation of a multi-slice CT system [J].
McCollough, CH ;
Zink, FE .
MEDICAL PHYSICS, 1999, 26 (11) :2223-2230
[10]   LOW-DOSE CT OF THE LUNGS - PRELIMINARY-OBSERVATIONS [J].
NAIDICH, DP ;
MARSHALL, CH ;
GRIBBIN, C ;
ARAMS, RS ;
MCCAULEY, DI .
RADIOLOGY, 1990, 175 (03) :729-731