Intraoperative Computed Tomography for Deep Brain Stimulation Surgery: Technique and Accuracy Assessment

被引:86
作者
Shahlaie, Kiarash
Larson, Paul S.
Starr, Philip A. [1 ]
机构
[1] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94143 USA
关键词
Computed tomography; Deep brain stimulation; Intraoperative imaging; Lead location; Neuronavigation; GLOBUS-PALLIDUS INTERNUS; SUBTHALAMIC NUCLEUS; ELECTRODE PLACEMENT; PARKINSONS-DISEASE; IMPLANTATION; LOCALIZATION; MRI; CANCER; SHIFT; EXPERIENCE;
D O I
10.1227/NEU.0b013e31820781bc
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The efficacy of deep brain stimulation (DBS) is highly dependent on the accuracy of lead placement. OBJECTIVE: To describe the use of intraoperative computed tomography (iCT) to confirm lead location before surgical closure and to study the accuracy of this technique. METHODS: Fifteen patients underwent awake microelectrode-guided DBS surgery in a stereotactic frame. A portable iCT scanner (Medtronic O-arm) was positioned around the patient's head throughout the procedure and was used to confirm lead location before fixation of the lead to the skull. Images were computationally fused with preoperative magnetic resonance imaging (MRI), and lead tip coordinates with respect to the midpoint of the anterior commissure-posterior commissure line were measured. Tip coordinates were compared with those obtained from postoperative MRI. RESULTS: iCT was integrated into standard frame-based microelectrode-guided DBS surgery with a minimal increase in surgical time or complexity. Technically adequate 2-dimensional and 3-dimensional images were obtained in all cases. Head positioning and fixation techniques that allow unobstructed imaging are described. Lead tip measurements on iCT fused with preoperative MRI were statistically indistinguishable from those obtained with postoperative MRI. CONCLUSION: iCT can be easily incorporated into standard DBS surgery, replaces the need for C-arm fluoroscopy, and provides accurate intraoperative 3-dimensional confirmation of electrode tip locations relative to preoperative images and surgical plans. iCT fused to preoperative MRI may obviate the need for routine postoperative MRI in DBS surgery. Technical nuances that must be mastered for the efficient use of iCT during DBS implantation are described.
引用
收藏
页码:114 / 124
页数:11
相关论文
共 28 条
[11]   Intraoperative X-Ray Detection and MRI-Based Quantification of Brain Shift Effects Subsequent to Implantation of the First Electrode in Bilateral Implantation of Deep Brain Stimulation Electrodes [J].
Hunsche, Stefan ;
Sauner, Dieter ;
Maarouf, Mohammad ;
Poggenborg, Joerg ;
Lackner, Klaus ;
Sturm, Volker ;
Treuer, Harald .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2009, 87 (05) :322-329
[12]   Single burr hole surgery for the spheno-orbital fibrous dysplasia using intraoperative computed tomography [J].
Kitai, R ;
Sato, K ;
Ido, K ;
Sakuma, T ;
Handa, Y ;
Kubota, T .
MINIMALLY INVASIVE NEUROSURGERY, 2005, 48 (01) :44-46
[13]   Magnetic resonance imaging of implanted deep brain stimulators: Experience in a large series [J].
Larson, Paul S. ;
Richardson, R. Mark ;
Starr, Philip A. ;
Martin, Alastair J. .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2008, 86 (02) :92-100
[14]   Deep brain stimulation in intraoperative MRI environment - Comparison of imaging techniques and electrode fixation methods [J].
Lee, MWY ;
De Salles, AAF ;
Frighetto, L ;
Torres, R ;
Behnke, E ;
Bronstein, JM .
MINIMALLY INVASIVE NEUROSURGERY, 2005, 48 (01) :1-6
[15]   Cortical electrode localization from X-rays and simple mapping for electrocorticographic research: The "Location on Cortex" (LOC) package for MATLAB [J].
Miller, Kai J. ;
Makeig, Scott ;
Hebb, Adam O. ;
Rao, Rajesh P. N. ;
denNijs, Marcel ;
Qjemann, Jeffrey G. .
JOURNAL OF NEUROSCIENCE METHODS, 2007, 162 (1-2) :303-308
[16]   Brain shift: an error factor during implantation of deep brain stimulation electrodes [J].
Miyagi, Yasushi ;
Shima, Fumio ;
Sasaki, Tomio .
JOURNAL OF NEUROSURGERY, 2007, 107 (05) :989-997
[17]   Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort Clinical article [J].
Nottmeier, Eric W. ;
Seemer, Will ;
Young, Phillip M. .
JOURNAL OF NEUROSURGERY-SPINE, 2009, 10 (01) :33-39
[18]   Accuracy and distortion of deep brain stimulation electrodes on postoperative MRI and CT [J].
Pinsker, M. O. ;
Herzog, J. ;
Falk, D. ;
Volkmann, J. ;
Deuschl, G. ;
Mehdorn, M. .
ZENTRALBLATT FUR NEUROCHIRURGIE, 2008, 69 (03) :144-147
[19]   Surgical Repositioning of Misplaced Subthalamic Electrodes in Parkinson's Disease: Location of Effective and Ineffective Leads [J].
Richardson, R. Mark ;
Ostrem, Jill L. ;
Starr, Philip A. .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2009, 87 (05) :297-303
[20]   MR IMAGING OF EXCESSIVELY OBESE PATIENTS - THE USE OF AN OPEN PERMANENT-MAGNET [J].
ROTHSCHILD, PA ;
DOMESEK, JM ;
EASTHAM, ME ;
KAUFMAN, L .
MAGNETIC RESONANCE IMAGING, 1991, 9 (02) :151-154