BACKGROUND: The efficacy of deep brain stimulation (DBS) is highly dependent on the accuracy of lead placement. OBJECTIVE: To describe the use of intraoperative computed tomography (iCT) to confirm lead location before surgical closure and to study the accuracy of this technique. METHODS: Fifteen patients underwent awake microelectrode-guided DBS surgery in a stereotactic frame. A portable iCT scanner (Medtronic O-arm) was positioned around the patient's head throughout the procedure and was used to confirm lead location before fixation of the lead to the skull. Images were computationally fused with preoperative magnetic resonance imaging (MRI), and lead tip coordinates with respect to the midpoint of the anterior commissure-posterior commissure line were measured. Tip coordinates were compared with those obtained from postoperative MRI. RESULTS: iCT was integrated into standard frame-based microelectrode-guided DBS surgery with a minimal increase in surgical time or complexity. Technically adequate 2-dimensional and 3-dimensional images were obtained in all cases. Head positioning and fixation techniques that allow unobstructed imaging are described. Lead tip measurements on iCT fused with preoperative MRI were statistically indistinguishable from those obtained with postoperative MRI. CONCLUSION: iCT can be easily incorporated into standard DBS surgery, replaces the need for C-arm fluoroscopy, and provides accurate intraoperative 3-dimensional confirmation of electrode tip locations relative to preoperative images and surgical plans. iCT fused to preoperative MRI may obviate the need for routine postoperative MRI in DBS surgery. Technical nuances that must be mastered for the efficient use of iCT during DBS implantation are described.
引用
收藏
页码:114 / 124
页数:11
相关论文
共 28 条
[1]   Improvement in Parkinson disease by subthalamic nucleus stimulation based on electrode placement [J].
Anheim, Mathieu ;
Batir, Alina ;
Fraix, Valerie ;
Silem, Madjid ;
Chabardes, Stephan ;
Seigneuret, Eric ;
Krack, Paul ;
Benabid, Alim-Louis ;
Pollak, Pierre .
ARCHIVES OF NEUROLOGY, 2008, 65 (05) :612-616
[2]   Reasons Women at Elevated Risk of Breast Cancer Refuse Breast MR Imaging Screening: ACRIN 6666 [J].
Berg, Wendie A. ;
Blume, Jeffrey D. ;
Adams, Amanda M. ;
Jong, Roberta A. ;
Barr, Richard G. ;
Lehrer, Daniel E. ;
Pisano, Etta D. ;
Evans, W. Phil, III ;
Mahoney, Mary C. ;
Larsen, Linda Hovanessian ;
Gabrielli, Glenna J. ;
Mendelson, Ellen B. .
RADIOLOGY, 2010, 254 (01) :79-87
[3]   Minimally invasive image-guided direct repair of bilateral L-5 pars interarticularis defects [J].
Brennan, Ryan P. ;
Smucker, Philip Y. ;
Horn, Eric M. .
NEUROSURGICAL FOCUS, 2008, 25 (02)
[4]   Intraoperative Use of the Medtronic O-arm for Deep Brain Stimulation Procedures [J].
Caire, F. ;
Gantois, C. ;
Torny, F. ;
Ranoux, D. ;
Maubon, A. ;
Moreau, J. J. .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2010, 88 (02) :109-114
[5]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[6]   REOPERATION FOR SUBOPTIMAL OUTCOMES AFTER DEEP BRAIN STIMULATION SURGERY [J].
Ellis, Tina-Marie ;
Foote, Kelly D. ;
Fernandez, Hubert H. ;
Sudhyadhom, Atchar ;
Rodriguez, Ramon L. ;
Zeilman, Pamela ;
Jacobson, Charles E., IV ;
Okun, Michael S. .
NEUROSURGERY, 2008, 63 (04) :754-760
[7]  
ENGLE DJ, 1987, J NEURO-ONCOL, V4, P361
[8]   Accuracy of stereotactic electrode placement in deep brain stimulation by intraoperative computed tomography [J].
Fiegele, Thomas ;
Feuchtner, Gudrun ;
Sohm, Florian ;
Bauer, Richard ;
Anton, Juergen Volker ;
Gotwald, Thaddaeus ;
Twerdy, Klaus ;
Eisner, Wilhelm .
PARKINSONISM & RELATED DISORDERS, 2008, 14 (08) :595-599
[9]   Brain shift during deep brain stimulation surgery for Parkinson's disease [J].
Halpern, Casey H. ;
Danish, Shabbar F. ;
Baltuch, Gordon H. ;
Jaggi, Jurg L. .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2008, 86 (01) :37-43
[10]   Semi-automatic stereotactic coordinate identification algorithm for routine localization of Deep Brain Stimulation electrodes [J].
Hebb, Adam O. ;
Miller, Kai J. .
JOURNAL OF NEUROSCIENCE METHODS, 2010, 187 (01) :114-119