Ultrasound Microvascular Imaging Based on Super-Resolution Radial Fluctuations

被引:26
作者
Zhang, Jiabin [1 ,2 ]
Li, Nan [4 ]
Dong, Feihong [1 ]
Liang, Shuyuan [4 ]
Wang, Di [1 ]
An, Jian [1 ]
Long, Yunfei [3 ]
Wang, Yuexiang [4 ]
Luo, Yukun [4 ]
Zhang, Jue [1 ,3 ]
机构
[1] Peking Univ, Acad Adv Interdisciplinary Studies, 5 Yiheyuan Rd, Beijing 100871, Peoples R China
[2] Peking Univ, Inst Mol Med, Beijing, Peoples R China
[3] Peking Univ, Coll Engn, Beijing, Peoples R China
[4] Chinese Peoples Liberat Army Gen Hosp, Dept Ultrasound, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
microbubbles; microscopy; super-resolution; ultrasound; CLINICAL-PRACTICE RECOMMENDATIONS; QUANTITATIVE-EVALUATION; CONTRAST; RECONSTRUCTION; GUIDELINES; CEUS;
D O I
10.1002/jum.15238
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives Super-resolution ultrasound (SRUS) has become a tool for in vivo microvascular imaging. Most of the SRUS methods are based on microbubble localization: namely, ultrasound localization microscopy (ULM). The aim of this study was to develop a nonlocalization SRUS method and verify its feasibility in microvascular imaging. Methods We introduce a new super-resolution strategy based on the postprocessing of contrast-enhanced ultrasound. The proposed method, which is termed ultrasound diffraction attenuation microscopy (UDAM), uses super-resolution radial fluctuations instead of microbubble localization to overcome acoustic diffraction limits. Biceps of Japanese long-ear white rabbits were adopted to validate its feasibility on muscle vascular imaging, using a clinical accessible ultrasound system at a frame rate of 30 Hz under a single bolus injection of SonoVue (Bracco SpA, Milan, Italy). The super-resolution image was compared with the maximum-intensity projection and ULM. Results The animal study illustrates that the proposed UDAM can obtain super-resolution microvascular images of rabbits' muscles under a single bolus injection of SonoVue with a 150-second contrast-enhanced ultrasound video. Both ULM and UDAM can achieve a very similar vascular structure with the maximum-intensity projection but much higher spatial resolution. The measurement of 1-dimensional signals shows that UDAM can distinguish the subwavelength structures and substantial reduce the full width at half-maximum of microvessels. Conclusions We conclude UDAM provides a noninvasive tool for in vivo super-resolution microvascular imaging.
引用
收藏
页码:1507 / 1516
页数:10
相关论文
共 40 条
[11]  
Couture O, 2011, IEEE INT ULTRA SYM, P1285, DOI 10.1109/ULTSYM.2011.6293576
[12]  
Cox S, 2012, NAT METHODS, V9, P195, DOI [10.1038/NMETH.1812, 10.1038/nmeth.1812]
[13]   Fast, background-free, 3D super-resolution optical fluctuation imaging (SOFI) [J].
Dertinger, T. ;
Colyer, R. ;
Iyer, G. ;
Weiss, S. ;
Enderlein, J. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (52) :22287-22292
[14]   Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging [J].
Errico, Claudia ;
Pierre, Juliette ;
Pezet, Sophie ;
Desailly, Yann ;
Lenkei, Zsolt ;
Couture, Olivier ;
Tanter, Mickael .
NATURE, 2015, 527 (7579) :499-+
[15]   Ultrasound localization microscopy to image and assess microvasculature in a rat kidney [J].
Foiret, Josquin ;
Zhang, Hua ;
Ilovitsh, Tali ;
Mahakian, Lisa ;
Tam, Sarah ;
Ferrara, Katherine W. .
SCIENTIFIC REPORTS, 2017, 7
[16]   Contrast enhanced maximum intensity projection ultrasound imaging for assessing angiogenesis in murine glioma and breast tumor models: A comparative study [J].
Forsberg, Flemming ;
Ro, Raymond J. ;
Fox, Traci B. ;
Liu, Ji-Bin ;
Chiou, See-Ying ;
Potoczek, Magdalena ;
Goldberg, Barry B. .
ULTRASONICS, 2011, 51 (03) :382-389
[17]  
Frazer P, 2016, ARDEN EARLY MOD DRAM, P1
[18]   Quantitative evaluation of microvascular blood flow by contrast-enhanced ultrasound (CEUS) [J].
Greis, Christian .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 49 (1-4) :137-149
[19]   Fast live-cell conventional fluorophore nanoscopy with ImageJ through super-resolution radial fluctuations [J].
Gustafsson, Nils ;
Culley, Sian ;
Ashdown, George ;
Owen, Dylan M. ;
Pereira, Pedro Matos ;
Henriques, Ricardo .
NATURE COMMUNICATIONS, 2016, 7
[20]  
Harput Sevan, 2017, 2017 IEEE International Ultrasonics Symposium (IUS), DOI 10.1109/ULTSYM.2017.8091727