The impact of building surface temperature rise on airflow and cross-contamination around high-rise building

被引:10
作者
Liu, Xiaoping [1 ]
Wu, Xiaojiao [1 ,2 ]
Wu, Mei [1 ]
Shi, Congling [3 ,4 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] First Design & Res Inst MI China Co Ltd, Hefei 230601, Anhui, Peoples R China
[3] China Acad Safety Sci & Technol, Inst Transportat Safety, Beijing, Peoples R China
[4] China Acad Safety Sci & Technol, Beijing Key Lab MFPTS, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
High-rise building; Pollutant; Temperature; Vortex core; Concentration; PEDESTRIAN WIND ENVIRONMENT; POLLUTANT DISPERSION; URBAN-ENVIRONMENT; CFD; INFECTION; RADIATION; RANS;
D O I
10.1007/s11356-020-07671-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper numerically studies the characteristics of flow field around a high-rise building and the cross-contamination when the building surface is heated by the solar radiation. Firstly, the normalized concentration K-c is used to evaluate the dispersion characteristics under different source locations without surface temperature rise. Under iso-thermal condition, the near-wall pollutant dispersion features revealed by the predicted results are similar to our previous wind tunnel experiment. Then, the effect of wall surface temperature rise on the cross-contamination and the flow fields is evaluated based on the near-wall concentration distributions and the wake zone vortex core positions, respectively. When the building surface temperature rises, the location of vortex core obviously changes comparing with that under iso-thermal condition. The correction formula for the vortex core location with the leeward wall surface temperature rise below 15 K is developed. The windward wall surface temperature rise brings more serious pollutant accumulation. The near-wall concentrations increase with the rise of temperature when the pollutant is released from the bottom and middle of leeward wall surface, while the top-release scenario exhibited a contrary tendency. For the three interval ranges of generally recognized Richardson number Ri (Ri < 0.1; 0.1 < Ri < 10; Ri > 10), these results indicate that when Ri is less than 0.1, the effect of wall surface temperature rise on near-wall flow and cross-contamination of small-scale model cannot be ignored.
引用
收藏
页码:11855 / 11869
页数:15
相关论文
共 42 条
[11]   Flow and dispersion in coupled outdoor and indoor environments: Issue of Reynolds number independence [J].
Dai, Yuwei ;
Mak, Cheuk Ming ;
Ai, Zhengtao .
BUILDING AND ENVIRONMENT, 2019, 150 :119-134
[12]   Variations in wind load on tall buildings due to urban development [J].
Elshaer, Ahmed ;
Gairola, Anant ;
Adamek, Kimberley ;
Bitsuamlak, Girma .
SUSTAINABLE CITIES AND SOCIETY, 2017, 34 :264-277
[13]  
Franke J, 2011, BEST PRACTICE GUIDEL, P732
[14]   Exploring the processes governing roadside pollutant concentrations in urban street canyon [J].
Galatioto, Fabio ;
Bell, Margaret C. .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (07) :4750-4765
[15]   The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation [J].
Gao, N. P. ;
Niu, J. L. ;
Perino, M. ;
Heiselberg, P. .
BUILDING AND ENVIRONMENT, 2008, 43 (11) :1805-1817
[16]   Impacts of shape and height of upstream roof on airflow and pollutant dispersion inside an urban street canyon [J].
Huang, Yuan-dong ;
He, Wen-rong ;
Kim, Chang-Nyung .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (03) :2117-2137
[17]   Local characteristics of cross-unit contamination around high-rise building due to wind effect: Mean concentration and infection risk assessment [J].
Liu, X. P. ;
Niu, J. L. ;
Kwok, K. C. S. ;
Wang, J. H. ;
Li, B. Z. .
JOURNAL OF HAZARDOUS MATERIALS, 2011, 192 (01) :160-167
[18]   Investigation of indoor air pollutant dispersion and cross-contamination around a typical high-rise residential building: Wind tunnel tests [J].
Liu, X. P. ;
Niu, J. L. ;
Kwok, K. C. S. ;
Wang, J. H. ;
Li, B. Z. .
BUILDING AND ENVIRONMENT, 2010, 45 (08) :1769-1778
[19]  
Liu XP, 2007, BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, P900
[20]   Evaluation of RANS turbulence models for simulating wind-induced mean pressures and dispersions around a complex-shaped high-rise building [J].
Liu, Xiaoping ;
Niu, Jianlei ;
Kwok, Kenny C. S. .
BUILDING SIMULATION, 2013, 6 (02) :151-164