Efficacy of adaptive servoventilation in treatment of complex and central sleep apnea syndromes

被引:118
作者
Allam, Joanne Shirine [2 ]
Olson, Eric J. [1 ]
Gay, Peter C. [1 ]
Morgenthaler, Timothy I. [1 ]
机构
[1] Mayo Clin, Mayo Clin Sleep Disorders Ctr, Rochester, MN 55905 USA
[2] Mayo Clin, Div Pulm & Crit Care Med, Rochester, MN 55905 USA
关键词
adaptive servoventilation; central sleep apnea; complex sleep apnea; positive pressure breathing;
D O I
10.1378/chest.07-1715
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Complex sleep apnea syndrome (CompSAS) is recognized by the concurrence of mixed or obstructive events with central apneas, the latter predominating on exposure to continuous positive airway pressure (CPAP). Treatment of CompSAS or central sleep apnea (CSA) syndrome with adaptive servoventilation (ASV) is now an option, but no large series exist describing the application and effectiveness of ASV. Methods: Retrospective chart review of the first 100 patients who underwent polysomnography using ASV at Mayo Clinic Sleep Center. Results: ASV titration was performed for CompSAS (63%), CSA (22%), or CSA/Cheyne Stokes breathing patterns (15%). The median diagnostic sleep apnea hypopnea index (AHI) was 48 events per hour (range, 24 to 62). With CPAP, obstructive apneas decreased, but the appearance of central apneas maintained the AHI at 31 events per hour (range, 17 to 47) [p = 0.02]. With bilevel positive airway pressure (BPAP) in spontaneous mode, AHI trended toward worsening vs baseline, with a median of 75 events per hour (range, 46 to 111) [p = 0.055]. BPAP with a backup rate improved the AHI to 15 events per hour (range, 11 to 31) [p = 0.002]. Use of ASV dramatically improved the AH1 to a mean of 5 events per hour (range, I to 11) vs baseline and vs CPAP (p < 0.0001). ASV also resulted in an increase in rapid eye movement sleep vs baseline and CPAP (18% vs 12% and 10%, respectively; p < 0.0001). Overall, 64 patients responded to the ASV treatment with a mean AH1 < 10 events per hour. Of the 44 successful survey follow-up patients contacted, 32 patients reported some improvement in sleep quality. Conclusion: The ASV device appears to be an effective treatment of both CompSAS and CSA syndromes that are resistant to CPAP.
引用
收藏
页码:1839 / 1846
页数:8
相关论文
共 21 条
[1]  
BONNET MH, 1992, SLEEP, V15, P526
[2]  
Bradley TD, 2006, J CLIN SLEEP MED, V2, P394
[3]   Continuous positive airway pressure for central sleep apnea and heart failure [J].
Bradley, TD ;
Logan, AG ;
Kimoff, RJ ;
Sériès, F ;
Morrison, D ;
Ferguson, K ;
Belenkie, I ;
Pfeifer, M ;
Fleetham, J ;
Hanly, P ;
Smilovitch, M ;
Tomlinson, G ;
Floras, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (19) :2025-2033
[4]   Clinical experience with adaptive support ventilation for fast-track cardiac surgery [J].
Cassina, T ;
Chioléro, R ;
Mauri, R ;
Revelly, JP .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (05) :571-575
[5]   Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research [J].
Flemons, WW ;
Buysse, D ;
Redline, S ;
Pack, A ;
Strohl, K ;
Wheatley, J ;
Young, T ;
Douglas, N ;
Levy, P ;
McNicholas, W ;
Fleetham, J ;
White, D ;
Schmidt-Nowarra, W ;
Carley, D ;
Romaniuk, J .
SLEEP, 1999, 22 (05) :667-689
[6]   Recognition and management of complex sleep-disordered breathing [J].
Gilmartin, GS ;
Daly, RW ;
Thomas, RJ .
CURRENT OPINION IN PULMONARY MEDICINE, 2005, 11 (06) :485-493
[7]   Effects of continuous positive airway pressure on sleep apnea and ventricular irritability in patients with heart failure [J].
Javaheri, S .
CIRCULATION, 2000, 101 (04) :392-397
[8]  
Javaheri S, 2000, SLEEP, V23, pS224
[9]  
Javaheri S, 2006, J CLIN SLEEP MED, V2, P399
[10]   Efficacy of nasal bi-level positive airway pressure in congestive heart failure patients with Cheyne-Stokes respiration and central sleep apnea [J].
Kasai, T ;
Narui, K ;
Dohi, T ;
Ishiwata, S ;
Yoshimura, K ;
Nishiyama, SI ;
Yamaguchi, T ;
Momomura, SI .
CIRCULATION JOURNAL, 2005, 69 (08) :913-921