Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

被引:11
作者
Jiang, Tingting [1 ]
Lee, Sang-Mi [1 ]
Hou, Yanan [1 ,2 ]
Chang, Xin [3 ]
Hwang, Hyeon-Shik [1 ,4 ]
机构
[1] Chonnam Natl Univ, Sch Dent, Dept Orthodont, Yongbong Ro 33, Gwangju 61186, South Korea
[2] Peking Univ, Sch Stomatol, Dept Orthodont, Beijing 100871, Peoples R China
[3] Dalian Med Univ, Dept Orthodont, Dalian, Peoples R China
[4] Chonnam Natl Univ, Dent Sci Res Inst, Gwangju 61186, South Korea
基金
新加坡国家研究基金会;
关键词
Digital dental model; Alginate impression; Dental cone-beam computed tomography; Dimensional accuracy; PLASTER MODELS; TOOTH WIDTHS; RELIABILITY; TIME; REPRODUCIBILITY; ACCURACY; VALIDITY; STORAGE;
D O I
10.4041/kjod.2016.46.3.129
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex-Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 17 条
[1]   The Relationship between Digital Model Accuracy and Time-Dependent Deformation of Alginate Impressions [J].
Alcan, Toros ;
Ceylanoglu, Cenk ;
Baysal, Bekir .
ANGLE ORTHODONTIST, 2009, 79 (01) :30-36
[2]   Predicting tooth-size discrepancy: A new formula utilizing revised landmarks and 3-dimensional laser scanning technology [J].
Bailey, Emil ;
Nelson, Gerald ;
Miller, Arthur J. ;
Andrews, Larry ;
Johnson, Earl .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 143 (04) :574-585
[3]  
Dahlberg G., 1940, STAT METHOD MEDICAL
[4]   DIMENSIONAL STABILITY OF CONTEMPORARY IRREVERSIBLE HYDROCOLLOIDS: HUMIDOR VERSUS WET TISSUE STORAGE [J].
Erbe, Christina ;
Ruf, Sabine ;
Woestmann, Bernd ;
Balkenhol, Markus .
JOURNAL OF PROSTHETIC DENTISTRY, 2012, 108 (02) :114-122
[5]   Orthodontic measurements on digital study models compared with plaster models: a systematic review [J].
Fleming, P. S. ;
Marinho, V. ;
Johal, A. .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2011, 14 (01) :1-16
[6]   Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner [J].
Fluegge, Tabea V. ;
Schlager, Stefan ;
Nelson, Katja ;
Nahles, Susanne ;
Metzger, Marc C. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (03) :471-478
[7]   Clinical use of a direct chairside oral scanner: An assessment of accuracy, time, and patient acceptance [J].
Gruenheid, Thorsten ;
McCarthy, Shawn D. ;
Larson, Brent E. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (05) :673-682
[8]   Assessment of the accuracy and reliability of new 3-dimensional scanning devices [J].
Hayashi, Kazuo ;
Sachdeva, Arjun U. C. ;
Saitoh, Sadamasa ;
Lee, Seung-Pyo ;
Kubota, Takao ;
Mizoguchi, Itaru .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (04) :619-625
[9]   Validity, reliability, and reproducibility of the iOC intraoral scanner: A comparison of tooth widths and Bolton ratios [J].
Naidu, Devan ;
Freer, Terrence J. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (02) :304-310
[10]  
Naidu D, 2009, AUST ORTHOD J, V25, P97