共 50 条
Optical Detection of λ-Cyhalothrin by Core-Shell Fluorescent Molecularly Imprinted Polymers in Chinese Spirits
被引:42
作者:
Wang, Jixiang
[1
]
Gao, Lin
[1
]
Han, Donglai
[3
,4
]
Pan, Jianming
[1
]
Qiu, Hao
[1
]
Li, Hongji
[1
]
Wei, Xiao
[2
]
Dai, Jiangdong
[1
,2
]
Yang, Jinghai
[4
]
Yao, Hui
[1
]
Yan, Yongsheng
[1
]
机构:
[1] Jiangsu Univ, Sch Chem & Chem Engn, Zhenjiang 212013, Peoples R China
[2] Jiangsu Univ, Sch Mat Sci & Engn, Zhenjiang 212013, Peoples R China
[3] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[4] Jilin Normal Univ, Minist Educ, Key Lab Funct Mat Phys & Chem, Siping 136000, Peoples R China
基金:
中国国家自然科学基金;
关键词:
lambda-cyhalothrin;
molecular imprinted polymer;
fluorescence detection;
selective recognition;
precipitation polymerization;
LAYER-CHROMATOGRAPHIC DETECTION;
PYRETHROID INSECTICIDES;
ELECTRON-CAPTURE;
EFFICIENT RECOGNITION;
PESTICIDE-RESIDUES;
SELECTIVE REMOVAL;
CARBON NANOTUBES;
EXTRACTION;
SURFACE;
QUANTIFICATION;
D O I:
10.1021/jf5043823
中图分类号:
S [农业科学];
学科分类号:
09 ;
摘要:
In this study, fluorescent molecularly imprinted polymers (FMIPs), which were for the selective recognition and fluorescence detection of lambda-cyhalothrin (LC), were synthesized via fluorescein 5(6)-isothiocyanate (FITC) and 3-aminopropyltriethoxysilane (APTS)/SiO2 particles. The SiO2@FITC-APTS@MIPs were characterized by Fourier transform infrared (FT-IR), UV-vis spectrophotometer (UV-vis), fluorescence spectrophotometer, thermogravimetric analysis (TGA), confocal laser scanning microscope (CLSM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The as-synthesized SiO2@FITC-APTS@MIPs with an imprinted polymer film (thickness was about 100 nm) was demonstrated to be spherically shaped and had good monodispersity, high fluorescence intensity, and good selective recognition. Using fluorescence quenching as the detection tool, the largest fluorescence quenching efficiency (F0/F - 1) of SiO2@FITC-APTS@MIPs is close to 2.5 when the concentration of the LC is 1.0 mu M L-1. In addition, a linear relationship (F0/F - 1= 0.0162C + 0.0272) could be obtained covering a wide concentration range of 0-60 nM L-1 with a correlation coefficient of 0.9968 described by the Stern-Volmer equation. Moreover, the limit of detection (LOD) of the SiO2@FITC-APTS@MIPs was 9.17 nM L-1. The experiment results of practical detection revealed that the SiO2@FITC-APTS@MIPs as an attractive recognition element was satisfactory for the determination of LC in Chinese spirits. Therefore, this study demonstrated the potential of SiO2@FITC-APTS@MIPs for the recognition and detection of LC in food.
引用
收藏
页码:2392 / 2399
页数:8
相关论文