Dose evaluation in paediatric patients undergoing chest X-ray examinations

被引:1
|
作者
Piantini, F. [1 ]
Schelin, H. R. [1 ]
Denyak, V. [1 ,2 ]
Bunick, A. P. [1 ]
Legnani, A. [1 ]
Ledesma, J. A. [1 ]
Fihpov, D. [3 ]
Paschuk, S. A. [3 ]
机构
[1] Pele Pequeno Principe Res Inst, Av Silva Jardim 1632, BR-80250060 Curitiba, PR, Brazil
[2] Kharkov Inst Phys & Technol, Natl Sci Ctr, Akad Skaya 1, UA-61108 Kharkov, Ukraine
[3] Fed Univ Technol, Av Sete Setembro 3165, BR-8023090 Curitiba, PR, Brazil
关键词
Dosimetry; Paediatric chest radiography; Patient anthropometric characteristics;
D O I
10.1016/j.radphyschem.2017.01.026
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to estimate the incident air kerma in chest X-ray examinations, for lateral (LAT) and anterior posterior (AP) (together with posterior anterior (PA)) projections, in one of the largest paediatric hospitals in Brazil, and to compare these with the results obtained in a general hospital of the same city. The dosimetric results were analysed along with the patient characteristics and radiographer strategies. The examinations of 225 (119 male and 106 female) patients were studied and 389 X-ray scans (200 AP/PA projections and 189 LAT projections) of paediatric patients were acquired. For analysis of the results, the patients were divided into the following age groups: 0-1 y, 1-5 y, 5-10 y, and 10-15 y. Patient's thickness can be determined from age, height or weight with an uncertainty of 20-30%. In different hospitals, the difference in patient's thicknesses between the same age groups can reach 25-55%. A minimal correlation between the patient dose and thickness was observed, with a 4 -fold difference in the dose for patients of the same thickness. By standardizing radiological protocols, it should be possible to keep the dose within intervals of 50-100 p mu Gy for LAT projection and 40-80 mu Gy for AP/PA projection.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 50 条
  • [41] Stationary chest tomosynthesis using a carbon nanotube x-ray source array: a feasibility study
    Shan, Jing
    Tucker, Andrew W.
    Lee, Yueh Z.
    Heath, Michael D.
    Wang, Xiaohui
    Foos, David H.
    Lu, Jianping
    Zhou, Otto
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01) : 81 - 100
  • [42] Fast dose calculation in x-ray guided interventions by using deep learning
    Villa, Mateo
    Nasr, Bahaa
    Benoit, Didier
    Padoy, Nicolas
    Visvikis, Dimitris
    Bert, Julien
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (16)
  • [43] Radiation exposure of children in pediatric radiology - Part 2: The PAEDOS algorithm for computer-assisted dose reconstruction in pediatric radiology and results for X-ray examinations of the skull
    Seidenbusch, M. C.
    Regulla, D.
    Schneider, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (06): : 522 - 539
  • [44] Assessment of the effects of CT dose in averaged x-ray CT images of a dose-sensitive polymer gel
    Kairn, T.
    Kakakhel, M. B.
    Johnston, H.
    Jirasek, A.
    Trapp, J. V.
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [45] Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators
    Belley, Matthew D.
    Wang, Chu
    Giao Nguyen
    Gunasingha, Rathnayaka
    Chao, Nelson J.
    Chen, Benny J.
    Dewhirst, Mark W.
    Yoshizumi, Terry T.
    MEDICAL PHYSICS, 2014, 41 (03)
  • [46] Generation and dose distribution measurement of flash x-ray in KALI-5000 system
    Menon, Rakhee
    Roy, Amitava
    Mitra, S.
    Sharma, A.
    Mondal, J.
    Mittal, K. C.
    Nagesh, K. V.
    Chakravarthy, D. P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)
  • [47] Measurement of radiotherapy superficial X-ray dose under eye shields with radiochromic film
    Butson, Martin J.
    Cheung, Tsang
    Yu, Peter K. N.
    Price, Sian
    Bailey, Michael
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2008, 24 (01): : 29 - 33
  • [48] Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light
    Hachadorian, R. L.
    Bruza, P.
    Jermyn, M.
    Gladstone, D. J.
    Pogue, B. W.
    Jarvis, L. A.
    NATURE COMMUNICATIONS, 2020, 11 (01)
  • [49] Absorbed dose determination in kilovoltage X-ray synchrotron radiation using alanine dosimeters
    D. J. Butler
    J. E. Lye
    T. E. Wright
    D. Crossley
    P. H. G. Sharpe
    A. W. Stevenson
    J. Livingstone
    J. C. Crosbie
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 943 - 950
  • [50] Comparison and calibration of dose delivered by 137Cs and x-ray irradiators in mice
    Caravaca, Javier
    Peter, Robin
    Yang, Jaewon
    Gunther, Chad
    Serrano, Juan Antonio Camara
    Nostrand, Christopher
    Steri, Veronica
    Seo, Youngho
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (22)