Dose evaluation in paediatric patients undergoing chest X-ray examinations

被引:1
|
作者
Piantini, F. [1 ]
Schelin, H. R. [1 ]
Denyak, V. [1 ,2 ]
Bunick, A. P. [1 ]
Legnani, A. [1 ]
Ledesma, J. A. [1 ]
Fihpov, D. [3 ]
Paschuk, S. A. [3 ]
机构
[1] Pele Pequeno Principe Res Inst, Av Silva Jardim 1632, BR-80250060 Curitiba, PR, Brazil
[2] Kharkov Inst Phys & Technol, Natl Sci Ctr, Akad Skaya 1, UA-61108 Kharkov, Ukraine
[3] Fed Univ Technol, Av Sete Setembro 3165, BR-8023090 Curitiba, PR, Brazil
关键词
Dosimetry; Paediatric chest radiography; Patient anthropometric characteristics;
D O I
10.1016/j.radphyschem.2017.01.026
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to estimate the incident air kerma in chest X-ray examinations, for lateral (LAT) and anterior posterior (AP) (together with posterior anterior (PA)) projections, in one of the largest paediatric hospitals in Brazil, and to compare these with the results obtained in a general hospital of the same city. The dosimetric results were analysed along with the patient characteristics and radiographer strategies. The examinations of 225 (119 male and 106 female) patients were studied and 389 X-ray scans (200 AP/PA projections and 189 LAT projections) of paediatric patients were acquired. For analysis of the results, the patients were divided into the following age groups: 0-1 y, 1-5 y, 5-10 y, and 10-15 y. Patient's thickness can be determined from age, height or weight with an uncertainty of 20-30%. In different hospitals, the difference in patient's thicknesses between the same age groups can reach 25-55%. A minimal correlation between the patient dose and thickness was observed, with a 4 -fold difference in the dose for patients of the same thickness. By standardizing radiological protocols, it should be possible to keep the dose within intervals of 50-100 p mu Gy for LAT projection and 40-80 mu Gy for AP/PA projection.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 50 条
  • [21] Characterization of dose delivery in a hard X-ray irradiation facility
    Lee, Ki-Man
    Kim, So-Ra
    Kim, Eun-Hee
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2012, 49 (06) : 655 - 661
  • [22] Dose area product in estimation of effective dose of the patients undergoing dental cone beam computed tomography examinations
    Kralik, Ivana
    Faj, Dario
    Lauc, Tomislav
    Skarica, Matko
    Popic, Jelena
    Brkic, Hrvoje
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (04) : 1412 - 1427
  • [23] Evaluation of equivalent dose from neutrons and activation products from a 15-MV X-ray LINAC
    Israngkul-Na-Ayuthaya, Isra
    Suriyapee, Sivalee
    Pengvanich, Phongpheath
    JOURNAL OF RADIATION RESEARCH, 2015, 56 (06) : 919 - 926
  • [24] Modeling a superficial radiotherapy X-ray source for relative dose calculations
    Johnstone, Christopher D.
    LaFontaine, Richard
    Poirier, Yannick
    Tambasco, Mauro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 118 - 130
  • [25] Dose distribution calculation for in-vivo X-ray fluorescence scanning
    Figueroa, R. G.
    Lozano, E.
    Valente, M.
    REVISTA MEXICANA DE FISICA, 2013, 59 (04) : 339 - 342
  • [26] Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields
    Kelaranta, Anna
    Ekholm, Marja
    Toroi, Paula
    Kortesniemi, Mika
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (01)
  • [27] THE CONCEPT OF X-RAY CT DOSE EVALUATION METHOD USING RADIOCHROMIC FILM AND FILM-FOLDING PHANTOM
    Tanki, Nobuyoshi
    Katsuda, Toshizo
    Gotanda, Rumi
    Gotanda, Tatsuhiro
    Imai, Shinya
    Kawaji, Yasuyuki
    Noguchi, Atsushi
    Kuwano, Tadao
    Fujita, Hideki
    Takeda, Yoshihiro
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (02) : 96 - 104
  • [28] Preliminary study on dose conversion parameters for absorbed dose to water in kV X-ray beams
    Kim, Yunho
    Yi, Chul-Young
    Kim, In Jung
    Park, Jong In
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 83 (03) : 226 - 232
  • [29] Preliminary study on dose conversion parameters for absorbed dose to water in kV X-ray beams
    Yunho Kim
    Chul-Young Yi
    In Jung Kim
    Jong In Park
    Journal of the Korean Physical Society, 2023, 83 : 226 - 232
  • [30] X-RAY DOSE ESTIMATION FROM CATHODE RAY TUBE MONITORS BY MONTE CARLO CALCULATION
    Khaledi, Navid
    Arbabi, Azim
    Dabaghi, Moloud
    HEALTH PHYSICS, 2015, 108 (04): : 401 - 406