System design and feasibility of trigeneration systems with hybrid photovoltaic-thermal (PVT) collectors for zero energy office buildings in different climates

被引:56
作者
Braun, Reiner [1 ]
Haag, Maximilian [2 ]
Stave, Jonas [2 ]
Abdelnour, Nermeen [2 ]
Eicker, Ursula [2 ,3 ]
机构
[1] Reutlingen Univ, HHZ, Danziger Str 6, D-71034 Boblingen, Germany
[2] Univ Appl Sci Stuttgart, Ctr Appl Res Sustainable Energy Technol Zafh Net, Schellingstr 24, D-70174 Stuttgart, Germany
[3] Concordia Univ, Dept Bldg Civil & Environm Engn, 1455 Maisonneuve W, Montreal, PQ H3G 1M8, Canada
关键词
Solar cooling; Hybrid PVT collectors; Economic and ecological analysis; Night radiative cooling; Zero energy office buildings; JET EJECTOR CHILLER; DOMESTIC HOT-WATER; COOLING SYSTEMS; SOLAR-SYSTEMS; LATENT-HEAT; PLATE; PV/T; PERFORMANCE; SIMULATION; PROSPECTS;
D O I
10.1016/j.solener.2019.12.005
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Zero or plus energy office buildings must have very high building standards and require highly efficient energy supply systems due to space limitations for renewable installations. Conventional solar cooling systems use photovoltaic electricity or thermal energy to run either a compression-cooling machine or an absorption-cooling machine in order to produce cooling energy during daytime, while they use electricity from the grid for the nightly cooling energy demand. With a hybrid photovoltaic-thermal collector, electricity as well as thermal energy can be produced at the same time. These collectors can produce also cooling energy at nighttime by long-wave radiation exchange with the night sky and convection losses to the ambient air. Such a renewable trigeneration system offers new fields of applications. However, the technical, ecological and economical aspects of such systems are still largely unexplored. In this work, the potential of a PVT system to heat and cool office buildings in three different climate zones is investigated. In the investigated system, PVT collectors act as a heat source and heat sink for a reversible heat pump. Due to the reduced electricity consumption (from the grid) for heat rejection, the overall efficiency and economics improve compared to a conventional solar cooling system using a reversible air-to-water heat pump as heat and cold source. A parametric simulation study was carried out to evaluate the system design with different PVT surface areas and storage tank volumes to optimize the system for three different climate zones and for two different building standards. It is shown such a systems are technically feasible today. With a maximum utilization of PV electricity for heating, ventilation, air conditioning and other electricity demand such as lighting and plug loads, high solar fractions and primary energy savings can be achieved. Annual costs for such a system are comparable to conventional solar thermal and solar electrical cooling systems. Nevertheless, the economic feasibility strongly depends on country specific energy prices and energy policy. However, even in countries without compensation schemes for energy produced by renewables, this system can still be economically viable today. It could be shown, that a specific system dimensioning can be found at each of the investigated locations worldwide for a valuable economic and ecological operation of an office building with PVT technologies in different system designs.
引用
收藏
页码:39 / 48
页数:10
相关论文
共 72 条
[1]  
AHK, 2013, AHK GESCH
[2]   A theoretical and experimental investigation of a radiative cooling system [J].
Al-Nimr, MA ;
Kodah, Z ;
Nassar, B .
SOLAR ENERGY, 1998, 63 (06) :367-373
[3]   Solar air conditioning in Europe - an overview [J].
Balaras, Constantinos A. ;
Grossman, Gershon ;
Henning, Hans-Martin ;
Infante Ferreira, Carlos A. ;
Podesser, Erich ;
Wang, Lei ;
Wiemken, Edo .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2007, 11 (02) :299-314
[4]   NOCTURNAL AND DIURNAL PERFORMANCES OF SELECTIVE RADIATORS [J].
BARTOLI, B ;
CATALANOTTI, S ;
COLUZZI, B ;
CUOMO, V ;
SILVESTRINI, V ;
TROISE, G .
APPLIED ENERGY, 1977, 3 (04) :267-286
[5]   Model calculations on a flat-plate solar heat collector with integrated solar cells [J].
Bergene, T ;
Lovvik, OM .
SOLAR ENERGY, 1995, 55 (06) :453-462
[6]   Hourly simulation and performance of solar electric-vapor compression refrigeration system [J].
Bilgili, Mehmet .
SOLAR ENERGY, 2011, 85 (11) :2720-2731
[7]   Surveys of nondomestic buildings in four English towns [J].
Brown, FE ;
Rickaby, PA ;
Bruhns, HR ;
Steadman, P .
ENVIRONMENT AND PLANNING B-PLANNING & DESIGN, 2000, 27 (01) :11-24
[8]   Solar heating and cooling systems by CPVT and ET solar collectors: A novel transient simulation model [J].
Buonomano, A. ;
Calise, F. ;
Palombo, A. .
APPLIED ENERGY, 2013, 103 :588-606
[9]   Design, Simulation and Experimental Investigation of a Solar System Based on PV Panels and PVT Collectors [J].
Buonomano, Annamaria ;
Calise, Francesco ;
Vicidomini, Maria .
ENERGIES, 2016, 9 (07)
[10]  
Cardinale N., 2010, International Journal of Energy and Environment, V1, P573