Streaming Potential-Based Arthroscopic Device is Sensitive to Cartilage Changes Immediately Post-Impact in an Equine Cartilage Injury Model

被引:29
作者
Changoor, A. [1 ]
Coutu, J. P. [1 ]
Garon, M. [2 ]
Quenneville, E. [2 ]
Hurtig, M. B. [3 ]
Buschmann, M. D. [1 ]
机构
[1] Ecole Polytech, Dept Chem Engn, Inst Biomed Engn, Montreal, PQ H3C 3A7, Canada
[2] Biomomentum Inc, Laval, PQ H7L 5C1, Canada
[3] Univ Guelph, Comparat Orthopaed Res Lab, Ontario Vet Coll, Guelph, ON N1G 2W1, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2011年 / 133卷 / 06期
基金
加拿大自然科学与工程研究理事会;
关键词
streaming potentials; cartilage biomechanics; impact injury; post-traumatic osteoarthritis; animal model; BOVINE ARTICULAR-CARTILAGE; PATELLOFEMORAL JOINT; CONTACT PRESSURES; IMPACT LOAD; STRAIN-RATE; COMPRESSION; MATRIX; DAMAGE; DEGRADATION; VIABILITY;
D O I
10.1115/1.4004230
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Models of post-traumatic osteoarthritis where early degenerative changes can be monitored are valuable for assessing potential therapeutic strategies. Current methods for evaluating cartilage mechanical properties may not capture the low-grade cartilage changes expected at these earlier time points following injury. In this study, an explant model of cartilage injury was used to determine whether streaming potential measurements by manual indentation could detect cartilage changes immediately following mechanical impact and to compare their sensitivity to biomechanical tests. Impacts were delivered ex vivo, at one of three stress levels, to specific positions on isolated adult equine trochlea. Cartilage properties were assessed by streaming potential measurements, made pre- and post-impact using a commercially available arthroscopic device, and by stress relaxation tests in unconfined compression geometry of isolated cartilage disks, providing the streaming potential integral (SPI), fibril modulus (Ef), matrix modulus (Em), and permeability (k). Histological sections were stained with Safranin-O and adjacent unstained sections examined in polarized light microscopy. Impacts were low, 17.3 +/- 2.7 MPa (n=15), medium, 27.8 +/- 8.5 MPa (n=13), or high, 48.7 +/- 12.1 MPa (n=16), and delivered using a custom-built spring-loaded device with a rise time of approximately 1 ms. SPI was significantly reduced after medium (p=0.006) and high (p<0.001) impacts. Ef, representing collagen network stiffness, was significantly reduced in high impact samples only (p<0.001 lateral trochlea, p=0.042 medial trochlea), where permeability also increased (p=0.003 lateral trochlea, p=0.007 medial trochlea). Significant (p<0.05, n=68) moderate to strong correlations between SPI and Ef (r=0.857), Em (r=0.493), log(k) (r=-0.484), and cartilage thickness (r=-0.804) were detected. Effect sizes were higher for SPI than Ef, Em, and k, indicating greater sensitivity of electromechanical measurements to impact injury compared to purely biomechanical parameters. Histological changes due to impact were limited to the presence of superficial zone damage which increased with impact stress. Non-destructive streaming potential measurements were more sensitive to impact-related articular cartilage changes than biomechanical assessment of isolated samples using stress relaxation tests in unconfined compression geometry. Correlations between electromechanical and biomechanical methods further support the relationship between non-destructive electromechanical measurements and intrinsic cartilage properties. [DOI: 10.1115/1.4004230]
引用
收藏
页数:9
相关论文
共 56 条
[1]   A DYNAMIC FINITE-ELEMENT ANALYSIS OF IMPULSIVE LOADING OF THE EXTENSION-SPLINTED RABBIT KNEE [J].
ANDERSON, DD ;
BROWN, TD ;
YANG, KH ;
RADIN, EL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02) :119-128
[2]   Impact loading: physiological or pathological? [J].
Aspden, RM ;
Jeffrey, JE ;
Burgin, LV .
OSTEOARTHRITIS AND CARTILAGE, 2002, 10 (07) :588-589
[3]   Characterization of experimentally induced post-traumatic osteoarthritis in the medial femorotibial joint of horses [J].
Bolam, CJ ;
Hurtig, MB ;
Cruz, A ;
McEwen, BJE .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2006, 67 (03) :433-447
[4]   Cartilage degradation and associated changes in biomechanical and electromechanical properties [J].
Bonassar, LJ ;
Jeffries, KA ;
Paguio, CG ;
Grodzinsky, AJ .
ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 :38-44
[5]   Inhibition of cartilage degradation and changes in physical properties induced by IL-1 beta and retinoic acid using matrix metalloproteinase inhibitors [J].
Bonassar, LJ ;
Sandy, JD ;
Lark, MW ;
Plaas, AHK ;
Frank, EH ;
Grodzinsky, AJ .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1997, 344 (02) :404-412
[6]   Cartilage tolerates single impact loads of as much as half the joint fracture threshold [J].
Borrelli, J ;
Zhu, Y ;
Burns, M ;
Sandell, L ;
Silva, MJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :266-273
[7]   Acute effects of cartilage impact [J].
Borrelli, J ;
Ricci, WM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (423) :33-39
[8]   Joint injury, repair, and remodeling [J].
Buckwalter, JA ;
Brown, TD .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (423) :7-16
[9]   Mapping of donor and recipient site properties for osteochondral graft reconstruction of subchondral cystic lesions in the equine stifle joint [J].
Changoor, A. ;
Hurtig, M. B. ;
Runciman, R. J. ;
Quesnel, A. J. ;
Dickey, J. P. ;
Lowerison, M. .
EQUINE VETERINARY JOURNAL, 2006, 38 (04) :330-336
[10]  
Changoor A, 2007, T ORTHOP RES SOC, P631