High resolution in vivo micro-CT with flat panel detector based on amorphous silicon

被引:31
作者
Yang, Xiaoquan [1 ]
Meng, Yuanzheng [1 ]
Luo, Qingming [1 ]
Gong, Hui [1 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Britton Chance Ctr Biomed Photon, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-CT; amorphous silicon; small animal imaging; BEAM COMPUTED-TOMOGRAPHY; X-RAY-DETECTORS; SYSTEM; VOLUME; ANGIOGRAPHY; CALIBRATION; SCANNER; DEVICE;
D O I
10.3233/XST-2010-0269
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-resolution in vivo micro-CT system for combining with fluorescence molecular tomography (FMT), was constructed and applied in small animal imaging. The fast scanning micro-CT system designed to provide high-resolution anatomic information and reconstruction priors, consisted of a flat panel detector (FPD) based on amorphous silicon (a-Si) and a micro-focus x-ray tube. The Feldkamp algorithm was adopted in image reconstruction with graphic processing unit (GPU). The system spatial resolution of 13 lp/mm was achieved when the diameter of image field was 6 cm with the system magnification factor of 4. No obvious beam hardening artifact was observed in transaxial image of a water phantom after correction. The contrast-to-noise ratio (CNR) study of various tissue phantoms was also presented. The in-vivo imaging of an anesthetic mouse was performed to demonstrate the feasibility of our system.
引用
收藏
页码:381 / 392
页数:12
相关论文
共 36 条
[1]   In vivo small-animal imaging using micro-CT and digital subtraction angiography [J].
Badea, C. T. ;
Drangova, M. ;
Holdsworth, D. W. ;
Johnson, G. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) :R319-R350
[2]   Spatial resolution properties in cone beam CT: A simulation study [J].
Chen, Lingyun ;
Shaw, Chris C. ;
Altunbas, Mustafa C. ;
Lai, Chao-Jen ;
Liu, Xinming .
MEDICAL PHYSICS, 2008, 35 (02) :724-734
[3]   SIGNAL AND NOISE IN MODULATION TRANSFER-FUNCTION DETERMINATIONS USING THE SLIT, WIRE, AND EDGE TECHNIQUES [J].
CUNNINGHAM, IA ;
REID, BK .
MEDICAL PHYSICS, 1992, 19 (04) :1037-1044
[4]   Magnetic resonance-coupled fluorescence tomography scanner for molecular imaging of tissue [J].
Davis, Scott C. ;
Pogue, Brian W. ;
Springett, Roger ;
Leussler, Christoph ;
Mazurkewitz, Peter ;
Tuttle, Stephen B. ;
Gibbs-Strauss, Summer L. ;
Jiang, Shudong S. ;
Dehghani, Hamid ;
Paulsen, Keith D. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (06)
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]  
FU JW, 2010, CHINESE OPT IN PRESS, V8
[7]   Simultaneous molecular and anatomical imaging of the mouse in vivo [J].
Goertzen, AL ;
Meadors, AK ;
Silverman, RW ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (24) :4315-4328
[8]   Charge-coupled device area x-ray detectors [J].
Gruner, SM ;
Tate, MW ;
Eikenberry, EF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08) :2815-2842
[9]   Noninvasive Monitoring of the Fate of 111In-Labeled Block Copolymer Micelles by High Resolution and High Sensitivity MicroSPECT/CT Imaging [J].
Hoang, Bryan ;
Lee, Helen ;
Reilly, Raymond M. ;
Allen, Christine .
MOLECULAR PHARMACEUTICS, 2009, 6 (02) :581-592
[10]   A HIGH-RESOLUTION XRII-BASED QUANTITATIVE VOLUME CT SCANNER [J].
HOLDSWORTH, DW ;
DRANGOVA, M ;
FENSTER, A .
MEDICAL PHYSICS, 1993, 20 (02) :449-462