The effect of transient fetal bradycardia and other heart rate changes during and after external cephalic version on perinatal outcomes

被引:7
作者
Hruban, Lukas [1 ,2 ]
Janku, Petr [1 ,2 ,4 ]
Jordanova, Kristyna [1 ,2 ]
Huptych, Michal [3 ]
Jouzova, Anna [1 ,2 ]
Gerychova, Romana [1 ,2 ]
Ventruba, Pavel [1 ,2 ]
机构
[1] Masaryk Univ, Univ Hosp Brno, Dept Obstet & Gynaecol, Brno, Czech Republic
[2] Masaryk Univ, Fac Med, Brno, Czech Republic
[3] Czech Tech Univ, Dept Cybernet, Fac Elect Engn, Prague, Czech Republic
[4] Masaryk Univ, Dept Nursing & Midwifery, Brno, Czech Republic
关键词
Breech presentation; External cephalic version; Fetal distress; Fetal bradycardia; HYPOTENSION; GESTATION; DELIVERY; BREECH;
D O I
10.1016/j.ejogrb.2019.11.025
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives: To evaluate the effect of transient fetal bradycardia and other heart rate changes during and after external cephalic version (ECV) on perinatal outcomes. To determine factors associated with a higher risk of occurrence of transient fetal bradycardia during and after ECV. Study design: Prospective study in 286 women after the 36th week of gestation with a fetus in breech presentation who have undergone an ECV attempt. The study analyses the incidence of transient fetal bradycardia during and immediately after ECV, the time interval to complete adjustment of fetal bradycardia, the factors associated with the occurrence of transient fetal bradycardia, cardiotocography (CTG) changes after ECV and perinatal outcomes. All the data were statistically analyzed. Results: The ECV was successful in 51 % (146/286). Transient fetal bradycardia occurred during and after ECV in 81 cases (28.3 %). A successful version was a factor significantly associated with fetal bradycardia (54; 37.0 %versus 27; 19.3 %; p < 0.01). Clinically significant hypotension of the mother was accompanied by transient fetal bradycardia in 12 cases (4.2 %). After the successful ECV there was no significant difference in the percentage of vaginal deliveries between subgroups with and without transient fetal bradycardia (85.2 % versus 83.7 %; p = 1.00). Nor in occurrence of acute fetal distress during labor (18.5 % versus 15.6 %; p = 0.65). In cases of a successful ECV transient CTG changes after ECV had no effect on the incidence of acute fetal distress during labor (23.5 % versus 15.7 %; p = 0.49). Conclusions: Transient fetal bradycardia and other heart rate changes during and immediately after ECV was not associated with a higher incidence of acute fetal distress during labor and did not affect perinatal outcomes. Higher occurrence of transient bradycardia after ECV was associated only with successful ECV. Transient hypotension of the mother as one of the causes of transient fetal bradycardia during ECV should be considered. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 23 条
  • [1] External Cephalic Version and Reducing the Incidence of Term Breech Presentation
    Impey, L. W. M.
    Murphy, D. J.
    Griffiths, M.
    Bray, Eaton
    Penna, L. K.
    Aggarwal, A.
    Akaba, G.
    Barrett, J. F. R.
    Bogner, G.
    Danielian, P. J.
    de Hundt, M.
    Diyaf, A.
    El-Sayed, Y.
    Fernando, R.
    Gillham, J. C.
    Hemelaar, J.
    Hinshaw, H. K. S.
    Kumar, B.
    Leung, T. Y.
    McGregor, E. G.
    Paterson-Brown, S.
    Robinson, S.
    Say, R. E.
    Sentilhes, L.
    Sheridan, M.
    Sung, H. P.
    Vlemmix, F.
    Weiniger, C. F.
    Gupta, M.
    Sarkar, P.
    Gupta, M.
    Owen, P.
    Thomson, A. J.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 (07) : E179 - E192
  • [2] Binder T, VELEBIL P 7 VEDENI P
  • [3] Fetomaternal hemorrhage during external cephalic version
    Boucher, Marc
    Marquette, Gerald P.
    Varin, Jocelyne
    Champagne, Josette
    Bujold, Emmanuel
    [J]. OBSTETRICS AND GYNECOLOGY, 2008, 112 (01) : 79 - 84
  • [4] External cephalic version: a safe procedure? A systematic review of version-related risks
    Collaris, RJ
    Oei, SG
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2004, 83 (06) : 511 - 518
  • [5] FRIEDMAN EA, 1978, JAMA-J AM MED ASSOC, V239, P2249
  • [6] External Cephalic Version-Related Risks A Meta-analysis
    Grootscholten, Kim
    Kok, Marjolein
    Oei, S. Guid
    Mol, Ben W. J.
    van der Post, Joris A.
    [J]. OBSTETRICS AND GYNECOLOGY, 2008, 112 (05) : 1143 - 1151
  • [7] GRUNBERGER W, 1979, GYNECOL OBSTET INVES, V10, P32
  • [8] The impact of physiological peripartal stress on the lifelong health of newborn
    Hederlingova, J.
    Psenkova, P.
    Zahumensky, J.
    [J]. BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2017, 118 (06): : 324 - 327
  • [9] CARDIOTOCOGRAPHIC CHANGES AFTER EXTERNAL CEPHALIC VERSION
    HOFMEYR, GJ
    SONNENDECKER, EWW
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1983, 90 (10): : 914 - 918
  • [10] Hotmeyr G.J., 2015, COCHRANE DATABASE SY