Temperature rise in pulp and gel during laser-activated bleaching: in vitro

被引:40
|
作者
Sari, Tugrul [1 ]
Celik, Gozde [1 ]
Usumez, Aslihan [1 ]
机构
[1] Bezmialem Vakif Univ, Dept Prosthodont, Fac Dent, TR-34093 Istanbul, Turkey
关键词
Temperature increase; Blood microcirculation in pulp; In-office bleaching; Er:YAG laser; Diode laser; DIODE-LASER; HEAT; EFFICACY; SURFACE; LIGHT;
D O I
10.1007/s10103-013-1375-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to evaluate the increase in temperature induced by various light sources during in-office bleaching treatment, under simulated blood microcirculation in pulp conditions. Ten freshly extracted human maxillary central incisors were used for the study. The roots of the teeth were removed from approximately 2 mm below the cementoenamel junction and fixed on an apparatus for the simulation of blood microcirculation in pulp. A J-type thermocouple wire was inserted into the pulp chamber through an artificial access at the lingual surfaces of the teeth, and another thermocouple wire was fixed on the labial surface of the teeth meanwhile. An in-office bleaching agent, intense red in color and with 30 % water content, was applied to the labial surfaces of the teeth, and repeating measurements were made for each tooth using three different light sources: Er:YAG laser (40 mJ, 10 Hz, 20 s), 810-nm diode laser (4 W, 20 s, CW), and high-intensity light-emitting diodes (LED) (1,100 mW/cm(2), 20 s) as the control. Temperature increase in the pulp chamber and within the bleaching gel during light application were recorded and statistically evaluated. The highest pulp temperature increases were recorded for the diode laser group (2.61 A degrees C), followed by the Er:YAG laser (1.86 A degrees C) and LED (1.02 A degrees C) groups (p < 0.05; analysis of variance (ANOVA), Tukey's honestly significant difference (HSD)). Contradictorily, the lowest gel temperature increases were recorded for diode laser (6.21 A degrees C) and followed by LED (12.38 A degrees C) and Er:YAG (20.11 A degrees C) groups (p < 0.05; ANOVA, Tukey's HSD). Despite the significant differences among the groups, the temperature increases recorded for all groups were below the critical value of 5.6 A degrees C that can cause irreversible harmful changes in pulp tissue. It can be concluded that, with regard to temperature increase, all the light sources evaluated in this study can be used safely for in-office bleaching treatment within the described parameters.
引用
收藏
页码:577 / 582
页数:6
相关论文
共 50 条
  • [21] In-vitro assessment of temperature rise in the pulp during orthodontic bonding
    Malkoc, Siddik
    Uysal, Tancan
    Usumez, Serdar
    Isman, Eren
    Baysal, Asli
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (03) : 379 - 383
  • [22] In vitro and in vivo tissue repair with laser-activated chitosan adhesive
    Lauto, A.
    Stoodley, M.
    Marcel, H.
    Avolio, A.
    Sarris, M.
    McKenzie, G.
    Sampson, D. D.
    Foster, L. J. R.
    LASERS IN SURGERY AND MEDICINE, 2007, 39 (01) : 19 - 27
  • [23] The effect of diode 980 nm laser-activated bleaching on surface roughness and color change in composite resin restorations (in vitro study)
    Hiba Al Helou
    Ibrahim Al-Ibrahim
    Bashar Sairafi
    Nour Al-Deen Kharboutly
    Joul Kassis
    Lasers in Dental Science, 8 (1)
  • [24] The effect of laser-activated bleaching with 810 nm and 980 nm diode lasers on enamel micro-hardness; an in vitro study
    Saati, Keyvan
    Orumchi, Azin
    Namdar, Fatemeh
    Jarrah, Azin
    Chiniforush, Nasim
    LASER PHYSICS, 2020, 30 (02)
  • [25] The effect of laser-activated bleaching with 445 nm and 915 nm diode lasers on enamel micro-hardness; an in vitro study
    Saberi, Sogol
    Rouzsaz, Mahboubeh
    Shafie, Farhad
    Einizadeh, Sadra
    Kharazifard, Mohammad Javad
    Shahabi, Sima
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 31
  • [26] Temperature rise in the pulp chamber during different stripping procedures - An in vitro study
    Baysal, Asli
    Uysal, Tancan
    Usumez, Serdar
    ANGLE ORTHODONTIST, 2007, 77 (03) : 478 - 482
  • [27] The effect of diode laser-activated bleaching on thermal changes and color outcomes of non-vital teeth using different laser parameters: an in vitro study
    Elzayat I.
    AbdelHamid M.B.
    Farouk A.T.
    Eldamanhoury H.M.I.
    Lasers in Dental Science, 2023, 7 (2) : 67 - 75
  • [28] Laser-Activated Polymeric Microcapsules for Ultrasound Imaging and Therapy: In Vitro Feasibility
    Lajoinie, Guillaume
    van Rooij, Tom
    Skachkov, Ilya
    Blazejewski, Emilie
    Veldhuis, Gert
    de Jong, Nico
    Kooiman, Klazina
    Versluis, Michel
    BIOPHYSICAL JOURNAL, 2017, 112 (09) : 1894 - 1907
  • [29] Laser-activated solid protein solder for nerve repair: In vitro studies of tensile strength and solder/tissue temperature
    McNally, KM
    Dawes, JM
    Parker, AE
    Lauto, A
    Piper, JA
    Owen, ER
    LASERS IN MEDICAL SCIENCE, 1999, 14 (03) : 228 - 237
  • [30] Correction to: The effect of diode laser-activated bleaching on thermal changes and color outcomes of non-vital teeth using different laser parameters: an in vitro study
    Inas Elzayat
    Mohamed Bahgat AbdelHamid
    Ahmed Tarek Farouk
    Hatem Mostafa El-Damanhoury
    Lasers in Dental Science, 2023, 7 (4) : 277 - 277