A liquid Xenon detector for micro-PET

被引:1
|
作者
Retiere, F. [1 ,2 ,3 ]
机构
[1] TRIUMF, Vancouver, BC V6T 2A3, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Univ Montreal, Montreal, PQ H3C 3J7, Canada
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2010年 / 623卷 / 01期
关键词
Positron emission tomography; Liquid Xenon; Compton reconstruction;
D O I
10.1016/j.nima.2010.03.080
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Liquid Xenon is a very promising technology for the new generation of Positron Emission Tomography detectors. The performance achieved by combining both scintillation light and ionization charge readout significantly exceeds the capabilities of conventional crystal based detectors. In these proceedings, we show that we achieved a 9.6% (full width half maximum) for 511 keV photons by combining light and charge. Then, we investigate the performance of a liquid Xenon micro-PET detector by running simulations and relying on a Compton reconstruction algorithm. The image quality is far superior to the existing FOCUS 120 micro-PET. Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:591 / 593
页数:3
相关论文
共 50 条
  • [1] Simulations of a micro-PET system based on liquid xenon
    Miceli, A.
    Glister, J.
    Andreyev, A.
    Bryman, D.
    Kurchaninov, L.
    Lu, P.
    Muennich, A.
    Retiere, F.
    Sossi, V.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (06): : 1685 - 1700
  • [2] Simulations of Scintillation Events in a High-Resolution Liquid Xenon Micro-PET System
    Clements, C.
    Bryman, D.
    Glister, J.
    Kurchaninov, L.
    Miceli, A.
    Retiere, F.
    Sossi, V.
    Zhu, H.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Performance study of liquid xenon detector for PET
    Chepel, V
    Lopes, MI
    Kuchenkov, A
    Marques, RF
    Policarpo, AJPL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 427 - 432
  • [4] The liquid xenon detector for PET: Recent results
    Chepel, V
    Solovov, V
    van der Marel, J
    Lopes, MI
    Crespo, P
    Janeiro, L
    Santos, D
    Marques, RF
    Policarpo, AJPL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1038 - 1044
  • [5] Liquid xenon detector for PET: recent results
    LIP-Coimbra and Physics Dep of the, Univ of Coimbra, Coimbra, Portugal
    IEEE Nucl Sci Symp Med Imaging Conf, (1426-1432):
  • [6] Performance study of liquid xenon detector for PET
    LIP-Coimbra and Departamento de, Fisica da Universidade de Coimbra, Coimbra, Portugal
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 392 (1-3): : 427 - 432
  • [7] A Liquid Xenon Detector for PET Applications: Simulated Performance
    Miceli, A.
    Andreyev, A.
    Bryman, D.
    Glister, J.
    Kurchaninov, L.
    Muennich, A.
    Retiere, F.
    Sossi, V.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [8] PURIFICATION OF LIQUID XENON AND IMPURITY MONITORING FOR A PET DETECTOR
    CHEPEL, VY
    LOPES, MI
    MARQUES, RF
    POLICARPO, AJPL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (2-3): : 500 - 505
  • [9] Performance Evaluation of Compton Micro-PET for Detector Modalities: A Monte Carlo Study
    Yoon, Changyeon
    Lee, Wonho
    NUCLEAR TECHNOLOGY, 2018, 204 (03) : 386 - 395
  • [10] Simulation results of a small animal liquid xenon pet detector
    Grondin, Y.
    Desvignes, M.
    Desbat, L.
    Mancini, S.
    Gallin-Martel, M-L.
    Gallin-Martel, L.
    Rossetto, O.
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1227 - +