Patent Foramen Ovale Closure Using a Bioabsorbable Closure Device Safety and Efficacy at 6-Month Follow-Up

被引:26
作者
Van den Branden, Ben J. [1 ]
Post, Martijn C. [1 ]
Plokker, Herbert W. [1 ]
ten Berg, Jurrien M. [1 ]
Suttorp, Maarten J. [1 ]
机构
[1] St Antonius Hosp, Dept Intervent Cardiol, NL-3435 CM Nieuwegein, Netherlands
关键词
closure; device; patent foramen ovale; transseptal catheter; SINGLE-CENTER EXPERIENCE; ATRIAL SEPTAL-DEFECT; TRANSCATHETER CLOSURE; PERCUTANEOUS CLOSURE; PARADOXICAL EMBOLISM; REPAIR IMPLANT; OCCLUDER; ECHOCARDIOGRAPHY; FEASIBILITY; PREVENTION;
D O I
10.1016/j.jcin.2010.06.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to assess the mid-term safety and efficacy of percutaneous patent foramen ovale (PFO) closure using a bioabsorbable device (BioSTAR, NMT Medical, Boston, Massachusetts). Background Closure of PFO in patients with cryptogenic stroke has proven to be safe and effective using different types of permanent devices. Methods All consecutive patients who underwent percutaneous PFO closure with the bioabsorbable closure device between November 2007 and January 2009 were included. Residual shunt was assessed using contrast transthoracic echocardiography. Results Sixty-two patients (55% women, mean age 47.7 +/- 11.8 years) underwent PFO closure. The in-hospital complications were a surgical device retrieval in 2 patients (3.2%), device reposition in 1 (1.6%), and a minimal groin hematoma in 6 patients (9.7%). The short-term complications at 1-month follow-up (n = 60) were a transient ischemic attack in the presence of a residual shunt in 1 patient and new supraventricular tachycardia in 7 patients (11.3%). At 6-month follow-up (n = 60), 1 patient without residual shunt developed a transient ischemic attack and 1 developed atrial fibrillation. A mild or moderate residual shunt was noted in 51.7%, 33.9%, and 23.7% after 1-day, 1-month, and 6-month follow-up, respectively. A large shunt was present in 8.3%, 3.4%, and 0% after 1-day, 1-month, and 6-month follow-up. Conclusions Closure of PFO using the bioabsorbable device is associated with a low complication rate and a low recurrence rate of embolic events. However, a relatively high percentage of mild or moderate residual shunting is still present at 6-month follow-up. (J Am Coll Cardiol Intv 2010;3: 968-73) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:968 / 973
页数:6
相关论文
共 26 条
[1]  
Alaeddini Jamshid, 2006, J Invasive Cardiol, V18, P365
[2]   Protocol for optimal detection and exclusion of a patent foramen ovale using transthoracic echocardiography with agitated saline microbubbles [J].
Attaran, Robert R. ;
Ata, Imran ;
Kudithipudi, Vijayasree ;
Foster, Laura ;
Sorrell, Vincent L. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (07) :616-622
[3]   Transcatheter closure of patent foramen ovale (PFO) in patients with paradoxical embolism - Periprocedural safety and mid-term follow-up results of three different device occluder systems [J].
Braun, M ;
Gliech, V ;
Boscheri, A ;
Schoen, S ;
Gahn, G ;
Reichmann, H ;
Haass, M ;
Schraeder, R ;
Strasser, RH .
EUROPEAN HEART JOURNAL, 2004, 25 (05) :424-430
[4]   Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder [J].
Divekar, A ;
Gaamangwe, T ;
Shaikh, N ;
Raabe, M ;
Ducas, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) :1213-1218
[5]   Percutaneous PFO Closure with Amplatzer PFO Occluder: Predictors of Residual Shunts at 6 Months Follow-up [J].
Greutmann, Matthias ;
Greutmann-Yantiri, Mehtap ;
Kretschmar, Oliver ;
Senn, Oliver ;
Roffi, Marco ;
Jenni, Rolf ;
Luescher, Thomas F. ;
Eberli, Franz R. .
CONGENITAL HEART DISEASE, 2009, 4 (04) :252-257
[6]   Transcatheter closure of atrial septal defect with a new flexible, self-centering device - (The STARFlex occluder) [J].
Hausdorf, G ;
Kaulitz, R ;
Paul, T ;
Carminati, M ;
Lock, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (09) :1113-+
[7]  
Hausdorf G, 2001, J Interv Cardiol, V14, P69, DOI 10.1111/j.1540-8183.2001.tb00715.x
[8]   Patent foramen ovale and stroke [J].
Homma, S ;
Sacco, RL .
CIRCULATION, 2005, 112 (07) :1063-1072
[9]   Interventional atrial septal defect closure using a totally bioresorbable occluder matrix - Development and preclinical evaluation of the BioSTAR device [J].
Jux, Christian ;
Bertram, Harald ;
Wohlsein, Peter ;
Bruegmann, Michael ;
Paul, Thomas .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :161-169
[10]  
Jux Christian, 2003, J Interv Cardiol, V16, P149, DOI 10.1046/j.1540-8183.2003.08027.x