Direct control of air-gap flux in permanent-magnet machines

被引:37
作者
Hsu, JS [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
field weakening; field control; permanent-magnet (PM) machines; motors; generators; electric vehicle; drives;
D O I
10.1109/60.900493
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A new field weakening and adjustment technology for PM machines by direct control of air-gap fluxes is introduced, This new technology requires no current decomposition by the inverter eliminating the need for a position sensor. Demagnetization, which normally occurs during field weakening, does not occur with this new method. The field-weakening ratio can reach 10:1 or higher. This technology is robust and particularly useful for, but not limited to, electric vehicle drives and PM generators.
引用
收藏
页码:361 / 365
页数:5
相关论文
共 5 条
[1]   EXPANSION OF OPERATING LIMITS FOR PERMANENT-MAGNET MOTOR BY CURRENT VECTOR CONTROL CONSIDERING INVERTER CAPACITY [J].
MORIMOTO, S ;
TAKEDA, Y ;
HIRASA, T ;
TANIGUCHI, K .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (05) :866-871
[2]  
NAMUDURI CS, 1998, P APEC 98 AN CAL FEB, V1, P34
[3]  
SEBASTIAN T, CH2272386 IEEE, P800
[4]   FIELD-WEAKENING PERFORMANCE OF BRUSHLESS SYNCHRONOUS AC MOTOR-DRIVES [J].
SOONG, WL ;
MILLER, TJE .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1994, 141 (06) :331-340
[5]  
SOZER Y, 1998, 1998 IEEE IND APPL C, V1, P475