Development and validation of a SlinkyTM ground heat exchanger model

被引:53
作者
Xiong, Zeyu [1 ]
Fisher, Daniel E. [1 ]
Spitler, Jeffrey D. [1 ]
机构
[1] Oklahoma State Univ, Sch Mech & Aerosp Engn, Stillwater, OK 74078 USA
关键词
Ground source heat pump; Horizontal ground heat exchanger; Slinks(TM) ground heat exchanger; Analytical solution; Simulation; BOREHOLE; SIMULATION;
D O I
10.1016/j.apenergy.2014.11.058
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ground source heat pump systems are an energy efficient heating and cooling technology for residential and commercial buildings. The main barrier to adoption is the higher investment cost compared to conventional systems. Where available land area permits, horizontal ground heat exchangers are generally less expensive than vertical borehole-type ground heat exchangers (GHXs). A further cost reduction can be made by using Slinky(TM) GHXs, which require less trench space and hence reduce the installation cost, in many cases. It is desirable to formulate an accurate model for simulation purposes; such simulations can be used in both design tools and in energy analysis programs. The model formulated in this paper relies on analytical ring source solutions to compute temperature response functions for both horizontal and vertical Slinky(TM) heat exchangers. The algorithms used to calculate the response factors have several features that significantly increase computation speed. The thermal effect of the ground surface temperature variation on the GHXs is considered by superimposing the undisturbed ground temperature, which is calculated using the numerical approach. For use in system simulations where the GHX may be connected to other components, the model is formulated to calculate both heat transfer rate and exiting fluid temperature, given entering fluid temperature. The model has been validated against the previously published field test data. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 69
页数:13
相关论文
共 32 条
  • [1] [Anonymous], 1986, Conduction of Heat in Solids
  • [2] Vertical temperature profile in ground heat exchanger during in-situ test
    Beier, Richard A.
    [J]. RENEWABLE ENERGY, 2011, 36 (05) : 1578 - 1587
  • [3] Chiasson A.D., 1999, Advances in modeling of ground-source heat pump systems
  • [4] Simulation of thermal performance of horizontal slinky-loop heat exchangers for ground source heat pumps
    Chong, Chiew Shan Anthony
    Gan, Guohui
    Verhoef, Anne
    Garcia, Raquel Gonzalez
    Vidale, Pier Luigi
    [J]. APPLIED ENERGY, 2013, 104 : 603 - 610
  • [5] CONDUCTIVE HEAT EXTRACTION TO A DEEP BOREHOLE - THERMAL ANALYSES AND DIMENSIONING RULES
    CLAESSON, J
    ESKILSON, P
    [J]. ENERGY, 1988, 13 (06) : 509 - 527
  • [6] Claesson J., 1983, HEAT EXTRACTION GROU
  • [7] Heat transfer analysis of ground heat exchangers with inclined boreholes
    Cui, P
    Yang, HX
    Fang, ZH
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) : 1169 - 1175
  • [8] Heat transfer analysis of pile geothermal heat exchangers with spiral coils
    Cui, Ping
    Li, Xin
    Man, Yi
    Fang, Zhaohong
    [J]. APPLIED ENERGY, 2011, 88 (11) : 4113 - 4119
  • [9] Eskilson P., 1987, Ph.D. Thesis
  • [10] Modeling of horizontal geoexchange systems for building heating and permafrost stabilization
    Fontaine, Pier-Olivier
    Marcotte, Denis
    Pasquier, Philippe
    Thibodeau, Denis
    [J]. GEOTHERMICS, 2011, 40 (03) : 211 - 220