Follow-up after polypropylene mesh repair of anterior and posterior compartments in patients with recurrent prolapse

被引:124
作者
Gauruder-Burmester, A.
Koutouzidou, P.
Rohne, J.
Gronewold, M.
Tunn, R.
机构
[1] St Hedwig Hosp, Dept Urogynecol, German Pelv Floor Ctr, D-10115 Berlin, Germany
[2] St Hedwig Hosp, Dept Surg, German Pelv Floor Ctr, D-10115 Berlin, Germany
关键词
dyspareunia; mesh erosion; monofilament polypropylene mesh; recurrent prolapse;
D O I
10.1007/s00192-006-0291-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
To retrospectively analyze the outcome of surgery in women followed up for 1 year after vaginal repair with the Apogee (R) (support of posterior vaginal wall) or Perigee (R) (support of anterior vaginal wall) system. A total of 120 patients with recurrent cystocele and/or rectocele or with combined vaginal vault prolapse were treated by either posterior or anterior mesh interposition depending on the defect. Follow-up after 1 year (+/- 31 days) comprised a vaginal examination with prolapse grading using the POP-Q system, measurement of vaginal length, evaluation of the vaginal mucosa, and exploration for mesh erosions. Postoperatively, 112 (93%) women were free of vaginal prolapse, whereas 8 (7%) had level 2 defects. Erosions occurred significantly more often (p=0.042) in patients treated with the Perigee system. Our results suggest that the Apogee (R) and Perigee (R) repair systems (monofilament polypropylene mesh) yield excellent short-term results after 1 year.
引用
收藏
页码:1059 / 1064
页数:6
相关论文
共 23 条
  • [1] Risk factors for mesh erosion after transvaginal surgery using polypropylene (Atrium) or composite polypropylene/polyglactin 910 (Vypro II) mesh
    Achtari, C
    Hiscock, R
    O'Reilly, BA
    Schierlitz, L
    Dwyer, PL
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2005, 16 (05) : 389 - 394
  • [2] Ahlers C. J., 2004, SEXUOLOGIE, V11, P74
  • [3] Severe mesh complications following intravaginal slingplasty
    Baessler, K
    Hewson, AD
    Tunn, R
    Schuessler, B
    Maher, CF
    [J]. OBSTETRICS AND GYNECOLOGY, 2005, 106 (04) : 713 - 716
  • [4] BAKER KR, 1990, SURG GYNECOL OBSTET, V171, P51
  • [5] Belot F, 2005, Gynecol Obstet Fertil, V33, P970, DOI 10.1016/j.gyobfe.2005.10.023
  • [6] Benhaim Y, 2006, J Gynecol Obstet Biol Reprod (Paris), V35, P219
  • [7] Tissue integration and tolerance to meshes used in gynecologic surgery: An experimental study
    Boulanger, Loic
    Boukerrou, Malik
    Lambaudie, Eric
    Defossez, Andre
    Cosson, Michel
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2006, 125 (01): : 103 - 108
  • [8] The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction
    Bump, RC
    Mattiasson, A
    Bo, K
    Brubaker, LP
    DeLancey, JOL
    Klarskov, P
    Shull, BL
    Smith, ARB
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 175 (01) : 10 - 17
  • [9] Cosson M, 2003, J Gynecol Obstet Biol Reprod (Paris), V32, P321
  • [10] A 2-year anatomical and functional assessment of transvaginal rectocele repair using a polypropylene mesh
    de Tayrac, R
    Picone, O
    Chauveaud-Lambling, A
    Fernandez, H
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2006, 17 (02) : 100 - 105