Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2-Part 2 ligand binding assays - impact of 25-hydroxyvitamin D2 and 24R,25-dihydroxyvitamin D3 on assay performance

被引:15
|
作者
Wise, Stephen A. [1 ,2 ]
Camara, Johanna E. [3 ]
Burdette, Carolyn Q. [3 ]
Hahm, Grace [3 ]
Nalin, Federica [3 ]
Kuszak, Adam J. [1 ]
Merkel, Joyce [1 ]
Durazo-Arvizu, Ramon A. [4 ]
Williams, Emma L. [5 ]
Popp, Christian [6 ]
Beckert, Christian [6 ]
Schultess, Jan [6 ]
Van Slooten, Glen [7 ]
Tourneur, Carole [8 ]
Pease, Camille [8 ]
Kaul, Ravi [9 ]
Villarreal, Alfredo [9 ]
Batista, Marcelo Cidade [10 ]
Pham, Heather [11 ]
Bennett, Alex [11 ]
Jansen, Eugene [12 ]
Khan, Dilshad Ahmed [13 ]
Kilbane, Mark [14 ]
Twomey, Patrick J. [14 ]
Freeman, James [15 ]
Parker, Neil [15 ]
Mushtaq, Sohail [16 ]
Simpson, Christine [17 ]
Lukas, Pierre [18 ]
Cavalier, Etienne [18 ]
Sempos, Christopher T. [1 ,19 ]
机构
[1] NIH, Off Dietary Supplements ODS, Bldg 10, Bethesda, MD 20892 USA
[2] NIST, Gaithersburg, MD 20899 USA
[3] NIST, Chem Sci Div, Gaithersburg, MD 20899 USA
[4] Univ Southern Calif, Keck Sch Med, Sabin Res Inst, Biostat Core, Los Angeles, CA 90027 USA
[5] Imperial Healthcare NHS Trust, London W6 8RF, England
[6] ADD Wiesbaden Abbott GmbH, Abbott Labs, D-65205 Wiesbaden, Germany
[7] Awareness Technol Inc, Palm City, FL 34990 USA
[8] bioMerieux, F-69280 Marcy Letoile, France
[9] Biorad Labs, Clin Diagnost, Hercules, CA 94547 USA
[10] Hosp Israelita Albert Einstein, Clin Lab, BR-05652900 Sao Paulo, Brazil
[11] Immunodiagnost Syst IDS, Boldon NE35 9PD, England
[12] Natl Inst Publ Hlth & Environm RIVM, NL-3720 BA Bilthoven, Netherlands
[13] Natl Univ Med Sci NUMS, Rawalpindi 46000, Pakistan
[14] St Vincents Univ Hosp, Clin Chem, Elm Pk, Dublin D04 T6F4 4, Ireland
[15] Siemens Healthineers, Tarrytown, NY 10591 USA
[16] Univ Chester, Chester CH1 4BJ, Cheshire, England
[17] Yale Univ, Sch Med, New Haven, CT USA
[18] Univ Liege, CHU Liege, Clin Chem, B-4000 Liege, Belgium
[19] Vitamin D Standardizat Program LLC, Havre De Grace, MD 21078 USA
基金
美国国家卫生研究院;
关键词
25-Hydroxyvitamin D-3 [25(OH)D-3; 25-Hydroxyvitamin D-2 [25(OH)D-2; Total 25-hydroxyvitamin D [25(OH)D; 24R; 25-Dihydroxyvitamin D-3 [24R; 25(OH)(2)D-3; Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Ligand binding assay; TANDEM MASS-SPECTROMETRY; BASE-LINE ASSESSMENT; D METABOLITES; AUTOMATED IMMUNOASSAYS; CLINICAL-EVALUATION; 25(OH)-VITAMIN D; US POPULATION; 25(OH) D; ACCURACY;
D O I
10.1007/s00216-021-03577-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D-2 [25(OH)D-2], 25-hydroxyvitamin D-3 [25(OH)D-3], 3-epi-25-hydroxyvitamin D-3 [3-epi-25(OH)D-3], and 24R,25-dihydroxyvitamin D-3 [24R,25(OH)(2)D-3] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 50% of the ligand binding assays achieved the VDSP criterion of mean % bias <= |+/- 5%|. For the 13 unique ligand binding assays evaluated in this study, only 4 assays were consistently within +/- 5% mean bias and 4 assays were consistently outside +/- 5% mean bias regardless of the laboratory performing the assay. Based on multivariable regression analysis using the concentrations of individual vitamin D metabolites in the 50 single-donor samples, most assays underestimate 25(OH)D-2 and several assays (Abbott, bioMerieux, DiaSorin, IDS-EIA, and IDS-iSYS) may have cross-reactivity from 24R,25(OH)(2)D-3. The results of this interlaboratory study represent the most comprehensive comparison of 25(OH)D ligand binding assays published to date and is the only study to assess the impact of 24R,25(OH)(2)D-3 content using results from a reference measurement procedure.
引用
收藏
页码:351 / 366
页数:16
相关论文
共 41 条