Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2-Part 2 ligand binding assays - impact of 25-hydroxyvitamin D2 and 24R,25-dihydroxyvitamin D3 on assay performance

被引:15
|
作者
Wise, Stephen A. [1 ,2 ]
Camara, Johanna E. [3 ]
Burdette, Carolyn Q. [3 ]
Hahm, Grace [3 ]
Nalin, Federica [3 ]
Kuszak, Adam J. [1 ]
Merkel, Joyce [1 ]
Durazo-Arvizu, Ramon A. [4 ]
Williams, Emma L. [5 ]
Popp, Christian [6 ]
Beckert, Christian [6 ]
Schultess, Jan [6 ]
Van Slooten, Glen [7 ]
Tourneur, Carole [8 ]
Pease, Camille [8 ]
Kaul, Ravi [9 ]
Villarreal, Alfredo [9 ]
Batista, Marcelo Cidade [10 ]
Pham, Heather [11 ]
Bennett, Alex [11 ]
Jansen, Eugene [12 ]
Khan, Dilshad Ahmed [13 ]
Kilbane, Mark [14 ]
Twomey, Patrick J. [14 ]
Freeman, James [15 ]
Parker, Neil [15 ]
Mushtaq, Sohail [16 ]
Simpson, Christine [17 ]
Lukas, Pierre [18 ]
Cavalier, Etienne [18 ]
Sempos, Christopher T. [1 ,19 ]
机构
[1] NIH, Off Dietary Supplements ODS, Bldg 10, Bethesda, MD 20892 USA
[2] NIST, Gaithersburg, MD 20899 USA
[3] NIST, Chem Sci Div, Gaithersburg, MD 20899 USA
[4] Univ Southern Calif, Keck Sch Med, Sabin Res Inst, Biostat Core, Los Angeles, CA 90027 USA
[5] Imperial Healthcare NHS Trust, London W6 8RF, England
[6] ADD Wiesbaden Abbott GmbH, Abbott Labs, D-65205 Wiesbaden, Germany
[7] Awareness Technol Inc, Palm City, FL 34990 USA
[8] bioMerieux, F-69280 Marcy Letoile, France
[9] Biorad Labs, Clin Diagnost, Hercules, CA 94547 USA
[10] Hosp Israelita Albert Einstein, Clin Lab, BR-05652900 Sao Paulo, Brazil
[11] Immunodiagnost Syst IDS, Boldon NE35 9PD, England
[12] Natl Inst Publ Hlth & Environm RIVM, NL-3720 BA Bilthoven, Netherlands
[13] Natl Univ Med Sci NUMS, Rawalpindi 46000, Pakistan
[14] St Vincents Univ Hosp, Clin Chem, Elm Pk, Dublin D04 T6F4 4, Ireland
[15] Siemens Healthineers, Tarrytown, NY 10591 USA
[16] Univ Chester, Chester CH1 4BJ, Cheshire, England
[17] Yale Univ, Sch Med, New Haven, CT USA
[18] Univ Liege, CHU Liege, Clin Chem, B-4000 Liege, Belgium
[19] Vitamin D Standardizat Program LLC, Havre De Grace, MD 21078 USA
基金
美国国家卫生研究院;
关键词
25-Hydroxyvitamin D-3 [25(OH)D-3; 25-Hydroxyvitamin D-2 [25(OH)D-2; Total 25-hydroxyvitamin D [25(OH)D; 24R; 25-Dihydroxyvitamin D-3 [24R; 25(OH)(2)D-3; Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Ligand binding assay; TANDEM MASS-SPECTROMETRY; BASE-LINE ASSESSMENT; D METABOLITES; AUTOMATED IMMUNOASSAYS; CLINICAL-EVALUATION; 25(OH)-VITAMIN D; US POPULATION; 25(OH) D; ACCURACY;
D O I
10.1007/s00216-021-03577-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D-2 [25(OH)D-2], 25-hydroxyvitamin D-3 [25(OH)D-3], 3-epi-25-hydroxyvitamin D-3 [3-epi-25(OH)D-3], and 24R,25-dihydroxyvitamin D-3 [24R,25(OH)(2)D-3] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 50% of the ligand binding assays achieved the VDSP criterion of mean % bias <= |+/- 5%|. For the 13 unique ligand binding assays evaluated in this study, only 4 assays were consistently within +/- 5% mean bias and 4 assays were consistently outside +/- 5% mean bias regardless of the laboratory performing the assay. Based on multivariable regression analysis using the concentrations of individual vitamin D metabolites in the 50 single-donor samples, most assays underestimate 25(OH)D-2 and several assays (Abbott, bioMerieux, DiaSorin, IDS-EIA, and IDS-iSYS) may have cross-reactivity from 24R,25(OH)(2)D-3. The results of this interlaboratory study represent the most comprehensive comparison of 25(OH)D ligand binding assays published to date and is the only study to assess the impact of 24R,25(OH)(2)D-3 content using results from a reference measurement procedure.
引用
收藏
页码:351 / 366
页数:16
相关论文
共 41 条
  • [21] Measurement of 25-hydroxyvitamin D2&3 and 1,25-dihydroxyvitamin D2&3 by tandem mass spectrometry: A primate multispecies comparison
    Ziegler, Toni E.
    Kapoor, Amita
    Hedman, Curtis J.
    Binkley, Neil
    Kemnitz, Joseph W.
    AMERICAN JOURNAL OF PRIMATOLOGY, 2015, 77 (07) : 801 - 810
  • [22] Influence of a single oral dose of vitamin D2 on serum 25-hydroxyvitamin D concentrations in tuberculosis patients
    Martineau, A. R.
    Nanzer, A. M.
    Satkunam, K. R.
    Packe, G. E.
    Rainbow, S. J.
    Maunsell, Z. J.
    Timms, R. M.
    Venton, T. R.
    Eldridge, S. M.
    Davidson, R. N.
    Wilkinson, R. J.
    Griffiths, C. J.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2009, 13 (01) : 119 - 125
  • [23] Performance characteristics of six automated 25-hydroxyvitamin D assays: Mind your 3s and 2s
    Wyness, Sara P.
    Straseski, Joely A.
    CLINICAL BIOCHEMISTRY, 2015, 48 (16-17) : 1089 - 1096
  • [24] Quantification of 25-hydroxyvitamin D2 and D3 in Mitra® devices with volumetric absorptive microsampling technology (VAMS®) by UHPLC-HRMS for regular vitamin D status monitoring
    Tuma, Chiara
    Thomas, Andreas
    Braun, Hans
    Thevis, Mario
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 228
  • [25] Assessment of serum total 25-hydroxyvitamin D assay commutability of Standard Reference Materials and College of American Pathologists Accuracy-Based Vitamin D (ABVD) Scheme and Vitamin D External Quality Assessment Scheme (DEQAS) materials: Vitamin D Standardization Program (VDSP) Commutability Study 2
    Camara, Johanna E.
    Wise, Stephen A.
    Hoofnagle, Andrew N.
    Williams, Emma L.
    Carter, Graham D.
    Jones, Julia
    Burdette, Carolyn Q.
    Hahm, Grace
    Nalin, Federica
    Kuszak, Adam J.
    Merkel, Joyce
    Durazo-Arvizu, Ramon A.
    Lukas, Pierre
    Cavalier, Etienne
    Popp, Christian
    Beckert, Christian
    Schultess, Jan
    Van Slooten, Glen
    Tourneur, Carole
    Pease, Camille
    Kaul, Ravi
    Villarreal, Alfredo
    Ivison, Fiona
    Fischer, Ralf
    van den Ouweland, Jody M. W.
    Ho, Chung S.
    Law, Emmett W. K.
    Simard, Jean-Nicolas
    Gonthier, Renaud
    Holmquist, Brett
    Batista, Marcelo Cidade
    Pham, Heather
    Bennett, Alex
    Meadows, Sarah
    Cox, Lorna
    Jansen, Eugene
    Khan, Dilshad Ahmed
    Robyak, Kimberly
    Creer, Michael H.
    Kilbane, Mark
    Twomey, Patrick J.
    Freeman, James
    Parker, Neil
    Yuan, Jinyun
    Fitzgerald, Robert
    Mushtaq, Sohail
    Clarke, Michael W.
    Breen, Norma
    Simpson, Christine
    Sempos, Christopher T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (20) : 5067 - 5084
  • [26] On-line SPE sample treatment as a tool for method automatization and detection limits reduction: Quantification of 25-hydroxyvitamin D3/D2
    Palaiogiannis, Dimitrios
    Bekou, Evangelia
    Pazaitou-Panayiotou, Kalliopi
    Samanidou, Victoria
    Tsakalof, Andreas
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1043 : 219 - 227
  • [27] Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma
    Zhang, Stanley
    Jian, Wenying
    Sullivan, Sheryl
    Sankaran, Banu
    Edom, Richard W.
    Weng, Naidong
    Sharkey, David
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 961 : 62 - 70
  • [28] A Simple, Rapid Atmospheric Pressure Chemical Ionization Liquid Chromatography Tandem Mass Spectrometry Method for the Determination of 25-Hydroxyvitamin D2 and D3
    Garg, Uttam
    Munar, Ada
    Frazee, Clinton, III
    Scott, David
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2012, 26 (05) : 349 - 357
  • [29] Assessment of serum total 25-hydroxyvitamin D assay commutability of Standard Reference Materials and College of American Pathologists Accuracy-Based Vitamin D (ABVD) Scheme and Vitamin D External Quality Assessment Scheme (DEQAS) materials: Vitamin D Standardization Program (VDSP) Commutability Study 2
    Johanna E. Camara
    Stephen A. Wise
    Andrew N. Hoofnagle
    Emma L. Williams
    Graham D. Carter
    Julia Jones
    Carolyn Q. Burdette
    Grace Hahm
    Federica Nalin
    Adam J. Kuszak
    Joyce Merkel
    Ramón A. Durazo-Arvizu
    Pierre Lukas
    Étienne Cavalier
    Christian Popp
    Christian Beckert
    Jan Schultess
    Glen Van Slooten
    Carole Tourneur
    Camille Pease
    Ravi Kaul
    Alfredo Villarreal
    Fiona Ivison
    Ralf Fischer
    Jody M. W. van den Ouweland
    Chung S. Ho
    Emmett W.K. Law
    Jean-Nicolas Simard
    Renaud Gonthier
    Brett Holmquist
    Marcelo Cidade Batista
    Heather Pham
    Alex Bennett
    Sarah Meadows
    Lorna Cox
    Eugene Jansen
    Dilshad Ahmed Khan
    Kimberly Robyak
    Michael H. Creer
    Mark Kilbane
    Patrick J. Twomey
    James Freeman
    Neil Parker
    Jinyun Yuan
    Robert Fitzgerald
    Sohail Mushtaq
    Michael W. Clarke
    Norma Breen
    Christine Simpson
    Christopher T. Sempos
    Analytical and Bioanalytical Chemistry, 2021, 413 : 5067 - 5084
  • [30] Development and validation of a liquid chromatography-tandem mass spectrometry assay for serum 25-hydroxyvitamin D2/D3 using a turbulent flow online extraction technology
    Bunch, Dustin R.
    Miller, Abby Y.
    Wang, Sihe
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (12) : 1565 - 1572