Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2-Part 2 ligand binding assays - impact of 25-hydroxyvitamin D2 and 24R,25-dihydroxyvitamin D3 on assay performance

被引:15
|
作者
Wise, Stephen A. [1 ,2 ]
Camara, Johanna E. [3 ]
Burdette, Carolyn Q. [3 ]
Hahm, Grace [3 ]
Nalin, Federica [3 ]
Kuszak, Adam J. [1 ]
Merkel, Joyce [1 ]
Durazo-Arvizu, Ramon A. [4 ]
Williams, Emma L. [5 ]
Popp, Christian [6 ]
Beckert, Christian [6 ]
Schultess, Jan [6 ]
Van Slooten, Glen [7 ]
Tourneur, Carole [8 ]
Pease, Camille [8 ]
Kaul, Ravi [9 ]
Villarreal, Alfredo [9 ]
Batista, Marcelo Cidade [10 ]
Pham, Heather [11 ]
Bennett, Alex [11 ]
Jansen, Eugene [12 ]
Khan, Dilshad Ahmed [13 ]
Kilbane, Mark [14 ]
Twomey, Patrick J. [14 ]
Freeman, James [15 ]
Parker, Neil [15 ]
Mushtaq, Sohail [16 ]
Simpson, Christine [17 ]
Lukas, Pierre [18 ]
Cavalier, Etienne [18 ]
Sempos, Christopher T. [1 ,19 ]
机构
[1] NIH, Off Dietary Supplements ODS, Bldg 10, Bethesda, MD 20892 USA
[2] NIST, Gaithersburg, MD 20899 USA
[3] NIST, Chem Sci Div, Gaithersburg, MD 20899 USA
[4] Univ Southern Calif, Keck Sch Med, Sabin Res Inst, Biostat Core, Los Angeles, CA 90027 USA
[5] Imperial Healthcare NHS Trust, London W6 8RF, England
[6] ADD Wiesbaden Abbott GmbH, Abbott Labs, D-65205 Wiesbaden, Germany
[7] Awareness Technol Inc, Palm City, FL 34990 USA
[8] bioMerieux, F-69280 Marcy Letoile, France
[9] Biorad Labs, Clin Diagnost, Hercules, CA 94547 USA
[10] Hosp Israelita Albert Einstein, Clin Lab, BR-05652900 Sao Paulo, Brazil
[11] Immunodiagnost Syst IDS, Boldon NE35 9PD, England
[12] Natl Inst Publ Hlth & Environm RIVM, NL-3720 BA Bilthoven, Netherlands
[13] Natl Univ Med Sci NUMS, Rawalpindi 46000, Pakistan
[14] St Vincents Univ Hosp, Clin Chem, Elm Pk, Dublin D04 T6F4 4, Ireland
[15] Siemens Healthineers, Tarrytown, NY 10591 USA
[16] Univ Chester, Chester CH1 4BJ, Cheshire, England
[17] Yale Univ, Sch Med, New Haven, CT USA
[18] Univ Liege, CHU Liege, Clin Chem, B-4000 Liege, Belgium
[19] Vitamin D Standardizat Program LLC, Havre De Grace, MD 21078 USA
基金
美国国家卫生研究院;
关键词
25-Hydroxyvitamin D-3 [25(OH)D-3; 25-Hydroxyvitamin D-2 [25(OH)D-2; Total 25-hydroxyvitamin D [25(OH)D; 24R; 25-Dihydroxyvitamin D-3 [24R; 25(OH)(2)D-3; Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Ligand binding assay; TANDEM MASS-SPECTROMETRY; BASE-LINE ASSESSMENT; D METABOLITES; AUTOMATED IMMUNOASSAYS; CLINICAL-EVALUATION; 25(OH)-VITAMIN D; US POPULATION; 25(OH) D; ACCURACY;
D O I
10.1007/s00216-021-03577-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D-2 [25(OH)D-2], 25-hydroxyvitamin D-3 [25(OH)D-3], 3-epi-25-hydroxyvitamin D-3 [3-epi-25(OH)D-3], and 24R,25-dihydroxyvitamin D-3 [24R,25(OH)(2)D-3] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 50% of the ligand binding assays achieved the VDSP criterion of mean % bias <= |+/- 5%|. For the 13 unique ligand binding assays evaluated in this study, only 4 assays were consistently within +/- 5% mean bias and 4 assays were consistently outside +/- 5% mean bias regardless of the laboratory performing the assay. Based on multivariable regression analysis using the concentrations of individual vitamin D metabolites in the 50 single-donor samples, most assays underestimate 25(OH)D-2 and several assays (Abbott, bioMerieux, DiaSorin, IDS-EIA, and IDS-iSYS) may have cross-reactivity from 24R,25(OH)(2)D-3. The results of this interlaboratory study represent the most comprehensive comparison of 25(OH)D ligand binding assays published to date and is the only study to assess the impact of 24R,25(OH)(2)D-3 content using results from a reference measurement procedure.
引用
收藏
页码:351 / 366
页数:16
相关论文
共 41 条
  • [1] Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 — Part 2 ligand binding assays — impact of 25-hydroxyvitamin D2 and 24R,25-dihydroxyvitamin D3 on assay performance
    Stephen A. Wise
    Johanna E. Camara
    Carolyn Q. Burdette
    Grace Hahm
    Federica Nalin
    Adam J. Kuszak
    Joyce Merkel
    Ramón A. Durazo-Arvizu
    Emma L. Williams
    Christian Popp
    Christian Beckert
    Jan Schultess
    Glen Van Slooten
    Carole Tourneur
    Camille Pease
    Ravi Kaul
    Alfredo Villarreal
    Marcelo Cidade Batista
    Heather Pham
    Alex Bennett
    Eugene Jansen
    Dilshad Ahmed Khan
    Mark Kilbane
    Patrick J. Twomey
    James Freeman
    Neil Parker
    Sohail Mushtaq
    Christine Simpson
    Pierre Lukas
    Étienne Cavalier
    Christopher T. Sempos
    Analytical and Bioanalytical Chemistry, 2022, 414 : 351 - 366
  • [2] Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2-Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D3 on assay performance
    Wise, Stephen A.
    Camara, Johanna E.
    Burdette, Carolyn Q.
    Hahm, Grace
    Nalin, Federica
    Kuszak, Adam J.
    Merkel, Joyce
    Durazo-Arvizu, Ramon A.
    Williams, Emma L.
    Hoofnagle, Andrew N.
    Ivison, Fiona
    Fischer, Ralf
    van den Ouweland, Jody M. W.
    Ho, Chung S.
    Law, Emmett W. K.
    Simard, Jean-Nicolas
    Gonthier, Renaud
    Holmquist, Brett
    Meadows, Sarah
    Cox, Lorna
    Robyak, Kimberly
    Creer, Michael H.
    Fitzgerald, Robert
    Clarke, Michael W.
    Breen, Norma
    Lukas, Pierre
    Cavalier, Etienne
    Sempos, Christopher T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (01) : 333 - 349
  • [3] Performance evaluation of four 25-hydroxyvitamin D assays to measure 25-hydroxyvitamin D2
    Freeman, James
    Wilson, Kimberly
    Spears, Ryan
    Shalhoub, Victoria
    Sibley, Paul
    CLINICAL BIOCHEMISTRY, 2015, 48 (16-17) : 1097 - 1104
  • [4] The recognition of 25-hydroxyvitamin D2 and D3 by a new binding protein based 25-hydroxyvitamin D assay
    Su, Zengliu
    Slay, Brian R.
    Carr, Randall
    Zhu, Yusheng
    CLINICA CHIMICA ACTA, 2013, 417 : 62 - 66
  • [5] Vitamin D Standardization Program (VDSP) intralaboratory study for the assessment of 25-hydroxyvitamin D assay variability and bias
    Wise, Stephen A.
    Camara, Johanna E.
    Sempos, Christopher T.
    Lukas, Pierre
    Le Goff, Caroline
    Peeters, Stephanie
    Burdette, Carolyn Q.
    Nalin, Federica
    Hahm, Grace
    Durazo-Arvizu, Ramon A.
    Kuszak, Adam J.
    Merkel, Joyce
    Cavalier, Etienne
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2021, 212
  • [6] The Importance of 25-Hydroxyvitamin D Assay Standardization and the Vitamin D Standardization Program
    Brooks, Stephen P. J.
    Sempos, Christopher T.
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (05) : 1223 - 1224
  • [7] The ratio of serum 24,25-dihydroxyvitamin D3 to 25-hydroxyvitamin D3 is predictive of 25-hydroxyvitamin D3 response to vitamin D3 supplementation
    Wagner, Dennis
    Hanwell, Heather E.
    Schnabl, Kareena
    Yazdanpanah, Mehrdad
    Kimball, Samantha
    Fu, Lei
    Sidhom, Gloria
    Rousseau, Derick
    Cole, David E. C.
    Vieth, Reinhold
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2011, 126 (3-5) : 72 - 77
  • [8] Baseline Assessment of 25-Hydroxyvitamin D Assay Performance: A Vitamin D Standardization Program (ASP) Interlaboratory Comparison Study
    Wise, Stephen A.
    Phinney, Karen W.
    Tai, Susan S. -C.
    Camara, Johanna E.
    Myers, Gary L.
    Durazo-Arvizu, Ramon
    Tian, Lu
    Hoofnagle, Andrew N.
    Bachmann, Lorin M.
    Young, Ian S.
    Pettit, Juanita
    Caldwell, Grahame
    Liu, Andrew
    Brooks, Stephen P. J.
    Sarafin, Kurtis
    Thamm, Michael
    Mensink, Gert B. M.
    Busch, Markus
    Rabenberg, Martina
    Cashman, Kevin D.
    Kiely, Mairead
    Kinsella, Michael
    Galvin, Karen
    Zhang, Joy Y.
    Oh, Kyungwon
    Lee, Sun-Wha
    Jung, Chae L.
    Cox, Lorna
    Goldberg, Gail
    Guberg, Kate
    Prentice, Ann
    Carter, Graham D.
    Jones, Julia
    Brannon, Patsy M.
    Lucas, Robyn M.
    Crump, Peter M.
    Cavalier, Etienne
    Merkel, Joyce
    Betz, Joseph M.
    Sempos, Christopher T.
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (05) : 1244 - 1252
  • [9] The Vitamin D Standardization Program (VDSP) Manual for Retrospective Laboratory Standardization of Serum 25-Hydroxyvitamin D Data
    Durazo-Arvizu, Ramon A.
    Tian, Lu
    Brooks, Stephen P. J.
    Sarafin, Kurtis
    Cashman, Kevin D.
    Kiely, Mairead
    Merkel, Joyce
    Myers, Gary L.
    Coates, Paul M.
    Sempos, Christopher T.
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (05) : 1234 - 1243
  • [10] Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2, vitamin D3, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3
    Adamec, Jiri
    Jannasch, Amber
    Huang, Jianjie
    Hohman, Emily
    Fleet, James C.
    Peacock, Munro
    Ferruzzi, Mario G.
    Martin, Berdine
    Weaver, Connie M.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (01) : 11 - 20