A new modified Tsuge suture for flexor tendon repairs: the biomechanical analysis and clinical application

被引:7
作者
Chen, Jianghai [1 ]
Wang, Kun [1 ]
Katirai, Foad [2 ]
Chen, Zhenbing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Wuhan Union Hosp, Dept Hand Surg, Wuhan 430022, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Med Coll, Wuhan 430010, Hubei, Peoples R China
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2014年 / 9卷
关键词
Flexor tendon; Repair; Modified Tsuge; Biomechanics; Clinical practice; EARLY ACTIVE MOBILIZATION; LOCKING; REHABILITATION; PREVENTION; STRENGTH; VIVO; HAND;
D O I
10.1186/s13018-014-0136-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study is to develop a new suturing technique for flexor tendon repair by modifying the extant Tsuge repair techniques and to use biomechanical analysis to compare the new method with four established repair techniques and evaluate its clinical efficacy in the repair of 47 flexor tendons in 22 patients. Methods: The biomechanical analysis relied on 50 flexor digitorum profundus tendons harvested from fresh cadavers. The tendons were randomly divided into five groups, transected, and repaired by use of a 1. double-loop suture, 2. double modified locking Kessler, 3. four-strand Savage, 4. modified six-strand Savage, and 5. the new technique. The tensile force and breaking force of all repaired tendons were measured by static loading trials. For clinical application, 22 patients with acute flexor tendon injuries were treated with the new modified Tsuge suture and follow-up for more than 12 months. Results: While differences in the tensile force and breaking force in the modified Tsuge sutures and modified six-strand Savage sutures were not statistically significant, static loading trials showed the tensile force, in the form of a 2-mm gap formation, and the breaking force of the new modified Tsuge sutures were, statistically, both higher than the ones characteristic of double-loop sutures, double modified locking Kessler, and four-strand Savage sutures. After 12 months, restored functions were observed in all the patients during the postoperative 12 months. Total active motion (TAM) score demonstrated that more than 90% fingers were estimated as excellent or good. Conclusion: The new modified Tsuge sutures described here have evident higher tensile and breaking forces compared to other four-strand core suture techniques, suggesting, in turn, that this new technique is a good alternative for flexor tendon repairs in clinical applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The Effects of Core Suture Purchase on the Biomechanical Characteristics of a Multistrand Locking Flexor Tendon Repair: A Cadaveric Study
    Lee, Steve K.
    Goldstein, Rachel Y.
    Zingman, Alissa
    Terranova, Carl
    Nasser, Philip
    Hausman, Michael R.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (07): : 1165 - 1171
  • [32] The Four-Strand Staggered Suture for Flexor Tendon Repair: In Vitro Biomechanical Study
    Corradi, Maurizio
    Bellan, Monia
    Frattini, Marco
    Concari, Galeazzo
    Tocco, Silvio
    Pogliacomi, Francesco
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (06): : 948 - 955
  • [33] Results of 4-strand modified Kessler core suture and epitendinous interlocking suture followed by modified Kleinert protocol for flexor tendon repairs in Zone 2
    Gunturk, Ozgun Bans
    Kayalar, Murat
    Kaplan, Ibrahim
    Uludag, Abuzer
    Ozaksar, Kemal
    Kelesoglu, Beray
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2018, 52 (05) : 382 - 386
  • [34] Evaluation of biomechanical properties on partial and complete epitendinous suture in human cadaver flexor tendon repair
    Kanchanathepsak, Thepparat
    Wairojanakul, Wilarat
    Suppaphol, Sorasak
    Watcharananan, Ittirat
    Tuntiyatorn, Panithan
    Tawonsawatruk, Tulyapruek
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [35] Letter to editor: The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair
    Chen, Jing
    Zhou, Xiang
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (07) : 1035 - 1036
  • [36] Vein grafts to augment flexor tendon repairs: a biomechanical study on strength and gap resistance
    Rodger, M. P.
    Theobald, P.
    Giddins, G.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2015, 40 (07) : 695 - 699
  • [37] Biomechanical comparison of the Lim/Tsai tendon repair with a modified method using a single looped suture
    Chang, Min Kai
    Wong, Yoke Rung
    Tay, Shian Chao
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2017, 42 (09) : 915 - 919
  • [38] BIOMECHANICAL COMPARISONS OF FOUR-STRAND TENDON REPAIRS WITH DOUBLE-STRANDED SUTURES: EFFECTS OF DIFFERENT LOCKS AND SUTURE GEOMETRY
    Wu, Y. F.
    Cao, Y.
    Zhou, Y. L.
    Tang, J. B.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2011, 36E (01) : 34 - 39
  • [39] A Biomechanical Comparison of 3 Loop Suture Materials in a 6-Strand Flexor Tendon Repair Technique
    Gan, Aaron W. T.
    Neo, Puay Yong
    He, Min
    Yam, Andrew K. T.
    Chong, Alphonsus K. S.
    Tay, Shian Chao
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (09): : 1830 - 1834
  • [40] Biomechanical Evaluation of Flexor Tendon Repair Using Barbed Suture Material: A Comparative Ex Vivo Study
    Zeplin, Philip H.
    Zahn, Robert K.
    Meffert, Rainer H.
    Schmidt, Karsten
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (03): : 446 - 449