A new modified Tsuge suture for flexor tendon repairs: the biomechanical analysis and clinical application

被引:7
|
作者
Chen, Jianghai [1 ]
Wang, Kun [1 ]
Katirai, Foad [2 ]
Chen, Zhenbing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Wuhan Union Hosp, Dept Hand Surg, Wuhan 430022, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Med Coll, Wuhan 430010, Hubei, Peoples R China
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2014年 / 9卷
关键词
Flexor tendon; Repair; Modified Tsuge; Biomechanics; Clinical practice; EARLY ACTIVE MOBILIZATION; LOCKING; REHABILITATION; PREVENTION; STRENGTH; VIVO; HAND;
D O I
10.1186/s13018-014-0136-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study is to develop a new suturing technique for flexor tendon repair by modifying the extant Tsuge repair techniques and to use biomechanical analysis to compare the new method with four established repair techniques and evaluate its clinical efficacy in the repair of 47 flexor tendons in 22 patients. Methods: The biomechanical analysis relied on 50 flexor digitorum profundus tendons harvested from fresh cadavers. The tendons were randomly divided into five groups, transected, and repaired by use of a 1. double-loop suture, 2. double modified locking Kessler, 3. four-strand Savage, 4. modified six-strand Savage, and 5. the new technique. The tensile force and breaking force of all repaired tendons were measured by static loading trials. For clinical application, 22 patients with acute flexor tendon injuries were treated with the new modified Tsuge suture and follow-up for more than 12 months. Results: While differences in the tensile force and breaking force in the modified Tsuge sutures and modified six-strand Savage sutures were not statistically significant, static loading trials showed the tensile force, in the form of a 2-mm gap formation, and the breaking force of the new modified Tsuge sutures were, statistically, both higher than the ones characteristic of double-loop sutures, double modified locking Kessler, and four-strand Savage sutures. After 12 months, restored functions were observed in all the patients during the postoperative 12 months. Total active motion (TAM) score demonstrated that more than 90% fingers were estimated as excellent or good. Conclusion: The new modified Tsuge sutures described here have evident higher tensile and breaking forces compared to other four-strand core suture techniques, suggesting, in turn, that this new technique is a good alternative for flexor tendon repairs in clinical applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Biomechanical Analysis of Partial Flexor Tendon Lacerations in Zone II of Human Cadavers
    Manning, David W.
    Spiguel, Andre R.
    Mass, Daniel P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (01): : 11 - 18
  • [22] A Technique for Suture Introduction in Multi-Strand Flexor Tendon Repairs
    Muzammil, Sohail
    Rao, Sajid Ejaz
    Rathore, Farooq Azam
    Malik, Naveed Ishaq
    Hobbs, Nigel John
    Aslam, Nadim
    TECHNIQUES IN ORTHOPAEDICS, 2009, 24 (04) : 317 - 318
  • [23] The effect of increased peripheral suture purchase on the strength of flexor tendon repairs
    Merrell, GA
    Wolfe, SW
    Kacena, WJ
    Gao, YT
    Cholewicki, J
    Kacena, MA
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (03): : 464 - 468
  • [24] A 3-Dimensional Suture Technique for Flexor Tendon Repair: A Biomechanical Study
    Castoldi, Marie
    Solla, Federico
    Camuzard, Olivier
    Pithioux, Martine
    Rampal, Virginie
    Rosello, Olivier
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (02): : 194e1 - 194e9
  • [25] Biomechanical Properties of a Novel Mesh Suture in a Cadaveric Flexor Tendon Repair Model
    Wallace, Stephen J.
    Mioton, Lauren M.
    Havey, Robert M.
    Muriuki, Muturi G.
    Ko, Jason H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (03): : 208 - 215
  • [26] Biomechanical properties of alternative suture technique for flexor tendon repair
    Andrzejewski, Tomasz
    Czarnecki, Piotr
    Dabrowski, Mikolaj
    Splawski, Robert
    Rogala, Piotr
    Romanowski, Leszek
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2017, 19 (01) : 167 - 172
  • [27] Biomechanical Comparison of a New Loop Suture Technique With Conventional Techniques of Flexor Tendon Repair An In Vitro Study
    Yildiran, Gokce
    Akdag, Osman
    Tosun, Zekeriya
    ANNALS OF PLASTIC SURGERY, 2019, 82 (04) : 441 - 444
  • [28] Zone II tendon repairs augmented with autogenous dorsal tendon graft: A biomechanical analysis
    Slade, JF
    Bhargava, M
    Barrie, KA
    Shenbagamurthi, D
    Wolfe, SW
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (05): : 813 - 820
  • [29] A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair
    Lawrence, TA
    Davis, TRC
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 836 - 841
  • [30] Comparison of a New Multifilament Stainless Steel Suture with Frequently Used Sutures for Flexor Tendon Repair
    McDonald, Erik
    Gordon, Joshua A.
    Buckley, Jenni M.
    Gordon, Leonard
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (06): : 1028 - 1034