A new modified Tsuge suture for flexor tendon repairs: the biomechanical analysis and clinical application

被引:7
|
作者
Chen, Jianghai [1 ]
Wang, Kun [1 ]
Katirai, Foad [2 ]
Chen, Zhenbing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Med Coll, Wuhan Union Hosp, Dept Hand Surg, Wuhan 430022, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Med Coll, Wuhan 430010, Hubei, Peoples R China
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2014年 / 9卷
关键词
Flexor tendon; Repair; Modified Tsuge; Biomechanics; Clinical practice; EARLY ACTIVE MOBILIZATION; LOCKING; REHABILITATION; PREVENTION; STRENGTH; VIVO; HAND;
D O I
10.1186/s13018-014-0136-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study is to develop a new suturing technique for flexor tendon repair by modifying the extant Tsuge repair techniques and to use biomechanical analysis to compare the new method with four established repair techniques and evaluate its clinical efficacy in the repair of 47 flexor tendons in 22 patients. Methods: The biomechanical analysis relied on 50 flexor digitorum profundus tendons harvested from fresh cadavers. The tendons were randomly divided into five groups, transected, and repaired by use of a 1. double-loop suture, 2. double modified locking Kessler, 3. four-strand Savage, 4. modified six-strand Savage, and 5. the new technique. The tensile force and breaking force of all repaired tendons were measured by static loading trials. For clinical application, 22 patients with acute flexor tendon injuries were treated with the new modified Tsuge suture and follow-up for more than 12 months. Results: While differences in the tensile force and breaking force in the modified Tsuge sutures and modified six-strand Savage sutures were not statistically significant, static loading trials showed the tensile force, in the form of a 2-mm gap formation, and the breaking force of the new modified Tsuge sutures were, statistically, both higher than the ones characteristic of double-loop sutures, double modified locking Kessler, and four-strand Savage sutures. After 12 months, restored functions were observed in all the patients during the postoperative 12 months. Total active motion (TAM) score demonstrated that more than 90% fingers were estimated as excellent or good. Conclusion: The new modified Tsuge sutures described here have evident higher tensile and breaking forces compared to other four-strand core suture techniques, suggesting, in turn, that this new technique is a good alternative for flexor tendon repairs in clinical applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A new modified Tsuge suture for flexor tendon repairs: the biomechanical analysis and clinical application
    Jianghai Chen
    Kun Wang
    Foad Katirai
    Zhenbing Chen
    Journal of Orthopaedic Surgery and Research, 9
  • [2] Comparison of a multifilament stainless steel suture with FiberWire for flexor tendon repairs - an in vitro biomechanical study
    McDonald, E.
    Gordon, J. A.
    Buckley, J. M.
    Gordon, L.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38E (04) : 418 - 423
  • [3] Biomechanical Evaluation of 4-Strand Flexor Tendon Repairs, Including a Combined Kessler-Tsuge Approach
    Renner, Christian
    Corella, Fernando
    Fischer, Nicole
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (02): : 229 - 235
  • [4] A Biomechanical Analysis of the Interlock Suture and a Modified Kessler-Loop Lock Flexor Tendon Suture
    Yang, Wenfeng
    Qiao, Dan
    Ren, Yuanfei
    Dong, Yvjin
    Shang, Yaohua
    Zhang, Tiehui
    CLINICS, 2017, 72 (09) : 582 - 587
  • [5] Intrasynovial flexor tendon repair: A biomechanical study of variations in suture application in human cadavera
    Nelson, Gregory N.
    Potter, Ryan
    Ntouvali, Eleni
    Silva, Matthew J.
    Boyer, Martin I.
    Gelberman, Richard H.
    Thomopoulos, Stavros
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (10) : 1652 - 1659
  • [6] Suture configurations and biomechanical properties of flexor tendon repairs by 16 hand surgeons in Finland
    Leppanen, O. V.
    Linnanmaki, L.
    Havulinna, J.
    Goransson, H.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2016, 41 (08) : 831 - 837
  • [7] A Modified Flexor Tendon Suture Technique Combining Kessler and Loop Lock Flexor Tendon Sutures
    Yang, Wenfeng
    Li, Jvtao
    Su, Yuewen
    Liang, Wu
    Ren, Yuanfei
    Dong, Yvjin
    Shang, Yaohua
    Zhong, Sheng
    Xu, Lianchun
    Zhang, Tiehui
    CLINICS, 2021, 76
  • [8] Biomechanical comparison of Bunnell, modified Kessler, and Tsuge tendon repair techniques using two suture types
    Dundar, Nuh
    Guneri, Bulent
    Uzel, Murat
    Doganer, Adem
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2020, 54 (01) : 104 - 112
  • [9] Biomechanical properties of four circumferential flexor tendon suture techniques
    Dona, E
    Turner, AWL
    Gianoutsos, MP
    Walsh, WR
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (05): : 824 - 831
  • [10] The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair
    Wieskoetter, B.
    Herbort, M.
    Langer, M.
    Raschke, M. J.
    Waehnert, D.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (01) : 139 - 145