Modeling and performance study of a water-injected twin-screw water vapor compressor

被引:40
作者
Tian, Yafen [1 ]
Shen, Jiubing [1 ,2 ]
Wang, Chuang [1 ]
Xing, Ziwen [1 ]
Wang, Xiaolin [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] Jiangsu Univ Sci & Technol, Sch Energy & Power Engn, 2 Mengxi Rd, Zhenjiang 212003, Peoples R China
[3] Univ Tasmania, Sch Engn & ICT, Hobart, Tas 7001, Australia
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2017年 / 83卷
基金
中国国家自然科学基金;
关键词
MVC system; Water injection; Twin screw compressor; p-V indicator diagram; Performance study; HEAT-PUMP; REFRIGERATION COMPRESSOR; WORKING PROCESS; DISTILLATION; RECOMPRESSION; SIMULATION; CYCLE; MVC;
D O I
10.1016/j.ijrefrig.2017.04.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Due to the reason of water injection, twin screw water vapor compressor can realize higher pressure ratio and saturated temperature lift of compressed vapor. Its application in mechanical vapor compression (MVC) heat pump systems has drawn much attention recently because of the great energy-saving potential and reliability. In this paper, a thermodynamic model of the working process in water injected twin screw water vapor compressor is established, in which heat and mass transfer between water liquid and vapor are considered. Its accuracy is validated by the experimental recorded p-V indicator diagrams. With the proposed model, the compressor performance is simulated and studied. According to the simulation results, water injection can increase the volumetric efficiency 5% and adiabatic indication efficiency 6%. Once the discharged vapor has been cooled to saturation, the shaft power of the compressor will increase while the adiabatic indication efficiency and the volume flow rate together with the volumetric efficiency change little with the continuous increase of injected water. Since the sensible heat of water is much smaller than latent heat, the temperature of injectedwater has little effect on the performance. Both the volume flowrate and shaft power increase linearly with the rotor speed. In addition, the volume flowrate of injectedwater should be adjusted with the regulation of rotor speed to guarantee a saturate discharge temperature. The volumetric efficiency will increase and the adiabatic indication efficiency will decrease slowly with the rise of rotor speed. Due to the cooling and evaporation effects of liquid water at the discharge chamber, the adiabatic indication efficiency does not decline when it operates at under compression condition. Water injection can greatly improve the compressor performance when the compressor operates at under compression or over compression condition, especially where a high saturated temperature lift of compressed vapor is in demand. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:75 / 87
页数:13
相关论文
共 50 条
  • [41] Structural characteristics of twin-screw compressor rotor based on thermal-solid coupling method
    Li, Tuolei
    Wang, Junli
    Lei, Shuai
    Zhang, Wensheng
    Ren, Zhigui
    JOURNAL OF VIBROENGINEERING, 2020, 22 (06) : 1534 - 1546
  • [42] Performance and bearing load analysis of a twin screw air compressor
    Lee, WS
    Ma, RH
    Wu, WF
    Chen, SL
    CHINESE JOURNAL OF MECHANICS-SERIES A, 1999, 15 (02): : 69 - 78
  • [43] Experimental investigation on the performance of a twin-screw expander used in an ORC system
    Hu, Fengfan
    Zhang, Zhen
    Chen, Wenqing
    He, Zhilong
    Wang, Xiaolin
    Xing, Ziwen
    1ST INTERNATIONAL CONFERENCE ON ENERGY AND POWER, ICEP2016, 2017, 110 : 210 - 215
  • [44] Influence of Screw Rotors Tip Angle on Mixing Performance for One Novel Twin-screw Kneader
    Wei, Jing
    Chen, Dabing
    Zhou, Dongming
    Zhang, Aiqiang
    Yang, Yuliang
    POLYMER-KOREA, 2015, 39 (03) : 441 - 452
  • [45] Theoretical and Experimental Studies on Oil Injected Twin Screw Air Compressor under Unload Conditions
    Liang, Xiangjing
    Wu, Wanrong
    2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2019, 252
  • [46] Effects of lubricating oil on the performance of a semi-hermetic twin screw refrigeration compressor
    Wu, Xiaokun
    Xing, Ziwen
    He, Zhilong
    Wang, Xiaolin
    Chen, Wenqing
    APPLIED THERMAL ENGINEERING, 2017, 112 : 340 - 351
  • [47] MODELING OF TWIN-SCREW EXTRUSION. PART II. MODEL VERIFICATION
    Wilczynski, Krzysztof
    White, James L.
    POLIMERY, 2009, 54 (01) : 51 - 56
  • [48] Performance analysis of a refrigerant extracting twin screw compressor employed in multi-temperature heat pump systems
    Zhao, Zhaorui
    Tian, Yafen
    Hou, Feng
    Xing, Ziwen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 383 - 394
  • [49] Vibration Characteristics Analysis of Twin-Screw Compressor Shell Based on the Fluid-Solid Coupling Method
    He, Yayin
    Zhang, Wei
    He, Xuyang
    Wang, Kai
    Wang, Junli
    Zhao, Yongqiang
    MECHANIKA, 2024, 30 (02): : 168 - 176
  • [50] Analysis of the Operational Characteristics and Performance Comparison of Steam Screw Pressure Matcher Based on Twin-Screw Expander
    Lin, Jianhui
    Lu, Shuyin
    Zhao, Ziliang
    Wang, Zijie
    Zhu, Ping
    Gu, Yujiong
    ENERGY SCIENCE & ENGINEERING, 2025, 13 (02) : 626 - 642