Modeling and performance study of a water-injected twin-screw water vapor compressor

被引:40
作者
Tian, Yafen [1 ]
Shen, Jiubing [1 ,2 ]
Wang, Chuang [1 ]
Xing, Ziwen [1 ]
Wang, Xiaolin [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] Jiangsu Univ Sci & Technol, Sch Energy & Power Engn, 2 Mengxi Rd, Zhenjiang 212003, Peoples R China
[3] Univ Tasmania, Sch Engn & ICT, Hobart, Tas 7001, Australia
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2017年 / 83卷
基金
中国国家自然科学基金;
关键词
MVC system; Water injection; Twin screw compressor; p-V indicator diagram; Performance study; HEAT-PUMP; REFRIGERATION COMPRESSOR; WORKING PROCESS; DISTILLATION; RECOMPRESSION; SIMULATION; CYCLE; MVC;
D O I
10.1016/j.ijrefrig.2017.04.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Due to the reason of water injection, twin screw water vapor compressor can realize higher pressure ratio and saturated temperature lift of compressed vapor. Its application in mechanical vapor compression (MVC) heat pump systems has drawn much attention recently because of the great energy-saving potential and reliability. In this paper, a thermodynamic model of the working process in water injected twin screw water vapor compressor is established, in which heat and mass transfer between water liquid and vapor are considered. Its accuracy is validated by the experimental recorded p-V indicator diagrams. With the proposed model, the compressor performance is simulated and studied. According to the simulation results, water injection can increase the volumetric efficiency 5% and adiabatic indication efficiency 6%. Once the discharged vapor has been cooled to saturation, the shaft power of the compressor will increase while the adiabatic indication efficiency and the volume flow rate together with the volumetric efficiency change little with the continuous increase of injected water. Since the sensible heat of water is much smaller than latent heat, the temperature of injectedwater has little effect on the performance. Both the volume flowrate and shaft power increase linearly with the rotor speed. In addition, the volume flowrate of injectedwater should be adjusted with the regulation of rotor speed to guarantee a saturate discharge temperature. The volumetric efficiency will increase and the adiabatic indication efficiency will decrease slowly with the rise of rotor speed. Due to the cooling and evaporation effects of liquid water at the discharge chamber, the adiabatic indication efficiency does not decline when it operates at under compression condition. Water injection can greatly improve the compressor performance when the compressor operates at under compression or over compression condition, especially where a high saturated temperature lift of compressed vapor is in demand. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:75 / 87
页数:13
相关论文
共 50 条
  • [21] Development and experimental study of a high-efficiency helium twin-screw compressor
    Wang, Chuang
    Xing, Ziwen
    Sun, Shizhong
    Yu, Zhiqiang
    CRYOGENICS, 2021, 116 (116)
  • [22] Study on the performance of the boil-off gas twin-screw compressor based on the thermal-fluid-structure coupling method
    Zhou, Yuhang
    Guo, Yi
    Wang, Yuli
    Diao, Anna
    Peng, Xueyuan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 163 : 17 - 31
  • [23] Theoretical research on the wear characteristics of rotors in a twin-screw compressor
    Wang, Chuang
    Xing, Ziwen
    Sun, Shizhong
    Chen, Wenqing
    He, Zhilong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2022, 236 (02) : 404 - 413
  • [24] An experimental technique to simulate and measure leakages in twin-screw compressor
    Patel, Hitesh H.
    Lakhera, Vikas J.
    ENGINEERING RESEARCH EXPRESS, 2021, 3 (01):
  • [25] Precision Grinding Process Design of Twin-screw Compressor Rotor
    Zhao, Yongqiang
    Zhao, Shengdun
    Hou, Hongling
    ADVANCED TECHNOLOGIES IN MANUFACTURING, ENGINEERING AND MATERIALS, PTS 1-3, 2013, 774-776 : 1107 - +
  • [26] Experimental study of lubricating oil impact on pressure pulsation for twin-screw refrigeration compressor
    Yang, Shengmei
    Ouyang, Hua
    Wu, Yadong
    Wang, Lee
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 112 : 324 - 332
  • [27] Energy and exergoeconomic analyses of parallel cross feed multi effect desalination system driven by twin-screw compressor with water injection
    Shamet, Osman
    Antar, Mohamed A.
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
  • [28] Thermal Potential of a Twin-Screw Compressor as Thermoelectric Energy Harvesting Source
    Savescu, Claudia
    Petrescu, Valentin
    Comeaga, Daniel
    Carlanescu, Razvan
    Roman, Mihaela
    Lale, Daniel
    Mitru, Andrei
    ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2024, 14 (02) : 13449 - 13455
  • [29] The Analysis of Twin-screw Compressor New Liquid Film Seal Structure
    Zhao, Jiangping
    Shi, Fusheng
    MATERIALS PROCESSING TECHNOLOGY II, PTS 1-4, 2012, 538-541 : 694 - +
  • [30] Experimental study on p-V indicator diagrams of twin-screw refrigeration compressor with economizer
    Wu, HG
    Peng, XY
    Xing, ZW
    Shu, PC
    APPLIED THERMAL ENGINEERING, 2004, 24 (10) : 1491 - 1500