Comparison of underivatized silica and zwitterionic sulfobetaine hydrophilic interaction liquid chromatography stationary phases for global metabolomics of human plasma

被引:13
作者
Sonnenberg, Rosalynde Ann [1 ]
Naz, Shama [1 ]
Cougnaud, Lise [1 ]
Vuckovic, Dajana [1 ]
机构
[1] Concordia Univ, Dept Chem & Biochem, 7141 Sherbrooke St West, Montreal, PQ H4B 1R6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
HILIC; Global metabolomics; Sulfobetaine stationary phase; Silica stationary phase; Human plasma; Mass spectrometry; MASS-SPECTROMETRY; SELECTIVITY; SEPARATION; RETENTION; MS; QUANTITATION; STRATEGIES; BEHAVIOR;
D O I
10.1016/j.chroma.2019.460419
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To increase metabolome coverage in global LC-MS metabolomics, often both reversed-phase liquid chromatography (RPLC) and hydrophilic-interaction liquid chromatography (HILIC) are implemented in parallel. However, there is a lack of consensus in the literature on the best HILIC stationary phase to employ for global metabolomics of human biological fluids. The objective of this study was to compare in detail the performance of two commonly employed HILIC phases: zwitterionic sulfobetaine ZIC-HILIC stationary phase and an underivatized silica HILIC stationary phase. During method development, the effect of salt concentration in the mobile phase was also investigated, and 5 mM ammonium acetate was selected. The stationary phases were evaluated using a mixture of 37 polar standards covering a range of logP values (-10 to 3.73), molecular weights (59-776 Da), charges (15 anions, 11 cations, and 11 neutral) as well as 17 lipid standards to understand phospholipid behaviour on the two stationary phases. The criteria used for the comparison included the quality of the chromatographic peak shape, adequate analyte retention, peak separation capability, and metabolite coverage. The zwitterionic ZIC-HILIC column provided better chromatographic performance over the silica stationary phase with 14 standards achieving good quality peaks compared to the 7 with the silica column. Only 2 standards were undetected with the ZIC-HILIC column compared to the 14 undetected with the silica column. In human plasma, 1966 and 1650 metabolites were observed on the ZIC-HILIC column in positive and negative electrospray ionization (ESI) respectively. On the silica HILIC column, 1773 and 2028 metabolites were observed in positive and negative ESI respectively, showing comparable performance of the two phases. Next, the effect of adding 10 mM ammonium phosphate to the samples to improve the analyte peak shape and metabolite coverage was investigated for both ZIC-HILIC and silica HILIC. In contrast with recently reported results for pZIC-HILIC, there was no clear evidence that ammonium phosphate addition was beneficial for human plasma samples. In conclusion, ZIC-HILIC provided better chromatographic performance for polar plasma metabolomics than underivatized silica in terms of chromatographic peak shape and chromatographic resolution, while maintaining comparable metabolite coverage. The addition of ammonium phosphate to human plasma was not beneficial for either of the two stationary phases. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 35 条
  • [11] Main Interactions and Influences of the Chromatographic Parameters in HILIC Separations
    Greco, Giorgia
    Letzel, Thomas
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2013, 51 (07) : 684 - 693
  • [12] Retention behavior of small polar compounds on polar stationary phases in hydrophilic interaction chromatography
    Guo, Y
    Gaiki, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1074 (1-2) : 71 - 80
  • [13] Comparison of peak shape in hydrophilic interaction chromatography using acidic salt buffers and simple acid solutions
    Heaton, James C.
    Russell, Joseph J.
    Underwood, Tim
    Boughtflower, Robert
    McCalley, David V.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1347 : 39 - 48
  • [14] A simple graphical representation of selectivity in hydrophilic interaction liquid chromatography
    Ibrahim, Mohammed E. A.
    Liu, Yang
    Lucy, Charles A.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1260 : 126 - 131
  • [15] The hydrophilicity vs. ion interaction selectivity plot revisited: The effect of mobile phase pH and buffer concentration on hydrophilic interaction liquid chromatography selectivity behavior
    Iverson, Chad D.
    Gu, Xinyun
    Lucy, Charles A.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1458 : 82 - 89
  • [16] Kohler I, 2016, LC GC EUR, V29, P60
  • [17] Practical investigation of the factors that affect the selectivity in hydrophilic interaction chromatography
    Kumar, Abhinav
    Heaton, James C.
    McCalley, David V.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1276 : 33 - 46
  • [18] LIQUID-CHROMATOGRAPHY OF SACCHARIDES
    LINDEN, JC
    LAWHEAD, CL
    [J]. JOURNAL OF CHROMATOGRAPHY, 1975, 105 (01): : 125 - 133
  • [19] Analytical strategies for LC-MS-based targeted metabolomics
    Lu, Wenyun
    Bennett, Bryson D.
    Rabinowitz, Joshua D.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02): : 236 - 242
  • [20] Selection of HILIC columns to handle matrix effect due to phospholipids
    Mess, Jean-Nicholas
    Cote, Cynthia
    Bergeron, Annik
    Furtado, Milton
    Garofolo, Fabio
    [J]. BIOANALYSIS, 2009, 1 (01) : 57 - 62