The effect of bupivacaine with fentanyl temperature on initiation and maintenance of labor epidural analgesia: a randomized controlled study

被引:15
|
作者
Sviggum, H. P. [1 ]
Yacoubian, S. [1 ]
Liu, X. [1 ]
Tsen, L. C. [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Anesthesiol Perioperat & Pain Med, Boston, MA 02115 USA
关键词
Epidural; Labor analgesia; Bupivacaine; Fentanyl; Temperature; Obstetric; MATERNAL TEMPERATURE; EXTRADURAL ANALGESIA; SPINAL-ANESTHESIA; FEVER; 0.5-PERCENT; INJECTION; DELIVERY; SPEED; BLOCK; WARM;
D O I
10.1016/j.ijoa.2014.07.001
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Labor epidural analgesia is highly effective, but can be limited by slow onset and incomplete blockade. The administration of warmed, compared to room temperature, bupivacaine has resulted in more rapid onset epidural anesthesia. We hypothesized that the administration of bupivacaine with fentanyl at 37 degrees C versus 20 degrees C would result in improved initial and ongoing labor epidural analgesia. Methods: In this prospective, randomized, doubled blinded study, 54 nulliparous, laboring women were randomized to receive epidural bupivacaine 0.125% with fentanyl 2 mu g/mL (20 mL initial and 6 mL hourly boluses) at either 37 degrees C or 20 degrees C. Pain verbal rating scores (VRS), sensory level, oral temperature, and side effects were assessed after epidural loading (time 0), at 5, 10, 15, 20, 30, 60 min, and at hourly intervals. The primary outcome was the time to achieve initial satisfactory analgesia (VRS <= 3) Secondary outcomes included ongoing quality of sensory blockade, body temperature and shivering. Results: There were no differences between groups in patient demographics, initial pain scores, cervical dilatation, body temperature or mode of delivery. Epidural bupivacaine at 37 degrees C resulted in shorter mean (+/- SD) analgesic onset time (9.2 +/- 4.7 vs. 16.0 +/- 10.5 min, P = 0.005) and improved analgesia for the first 15 min after initial bolus (P = 0.001-0.03). Although patient temperature increased during the study (P < 0.01), there were no differences between the groups (P = 0.09). Six (24%) and 10 (40%) patients experienced shivering in the 37 degrees C and 20 degrees C groups, respectively (P = 0.23). Conclusions: The administration of epidural 0.125% bupivacaine with fentanyl 2 mu g/mL at 37 degrees C versus 20 degrees C resulted in more rapid onset and improved labor analgesia for the first 15 min. There was no evidence of improved ongoing labor analgesia or differences in side effects between groups. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 50 条
  • [31] OBSTETRIC EPIDURAL ANALGESIA WITH MIXTURES OF BUPIVACAINE, ADRENALINE AND FENTANYL
    YAU, G
    GREGORY, MA
    GIN, T
    OH, TE
    ANAESTHESIA, 1990, 45 (12) : 1020 - 1023
  • [32] A COMPARATIVE STUDY OF BUPIVACAINE AND FENTANYL V/s BUPIVACAINE AND BUTORPHANOL IN LABOUR ANALGESIA BY EPIDURAL TECHNIQUE
    Reddy, K. Nagarjuna
    Sachidanand, R. S.
    Rao, B. Srinivas
    Devulapalli, Praveen Kumar
    Nagender, T.
    Srinath, M.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (79): : 13799 - 13813
  • [33] Does bupivacaine and fentanyl combination for epidural analgesia shorten the duration of labour?
    Genc, M.
    Sahin, N.
    Maral, J.
    Celik, E.
    Kar, A. A.
    Usar, P.
    Korkut, B.
    Guclu, S.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2015, 35 (07) : 672 - 675
  • [34] The effect on maternal temperature of delaying initiation of the epidural component of combined spinal-epidural analgesia for labor: a pilot study
    Wang, L. Z.
    Chang, X. Y.
    Hu, X. X.
    Tang, B. L.
    Xia, F.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2011, 20 (04) : 312 - 317
  • [35] Epidural Analgesia During the Second Stage of Labor A Randomized Controlled Trial
    Shen, XiaoFeng
    Li, Yunping
    Xu, ShiQin
    Wang, Nan
    Fan, Sheng
    Qin, Xiang
    Zhou, Chunxiu
    Hess, Philip E.
    OBSTETRICS AND GYNECOLOGY, 2017, 130 (05) : 1097 - 1103
  • [36] A comparison of 0.1% ropivacaine and 0.1% bupivacaine with patient-controlled epidural analgesia for labor: a double blind study
    Anand, Lakesh K.
    Sarna, Rashi
    Mitra, Sukanya
    ANAESTHESIA PAIN & INTENSIVE CARE, 2016, 20 (03) : 278 - 284
  • [37] THE EFFECT OF INTRAPARTUM EPIDURAL ANALGESIA ON NULLIPAROUS LABOR - A RANDOMIZED, CONTROLLED, PROSPECTIVE TRIAL
    THORP, JA
    HU, DH
    ALBIN, RM
    MCNITT, J
    MEYER, BA
    COHEN, GR
    YEAST, JD
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (04) : 851 - 858
  • [38] Randomized controlled comparison of epidural bupivacaine versus pethidine for analgesia in labour
    Loughnan, BA
    Carli, F
    Romney, M
    Doré, CJ
    Gordon, H
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (06) : 715 - 719
  • [39] Comparison of Programmed Intermittent Epidural Boluses With Continuous Epidural Infusion for the Maintenance of Labor Analgesia: A Randomized, Controlled, Double-Blind Study
    Ojo, Oluremi A.
    Mehdiratta, Jennifer E.
    Gamez, Brock H.
    Hunting, John
    Habib, Ashraf S.
    ANESTHESIA AND ANALGESIA, 2020, 130 (02) : 426 - 435
  • [40] A Randomized Controlled Comparison of Epidural Analgesia Onset Time and Adverse Reactions During Labor With Different Dose Combinations of Bupivacaine and Sufentanil
    Wang, Tingting
    Lu, Yaojun
    Zhou, Peiwen
    Huang, Shaoqiang
    Yu, Xinhua
    CLINICAL JOURNAL OF PAIN, 2020, 36 (08) : 612 - 617