Corrosion behaviour of Ti6A14V ELI nanotubes for biomedical applications

被引:25
|
作者
Lario, Joan [1 ]
Viera, Mauricio [1 ]
Vicente, Angel [1 ]
Igual, A. [2 ]
Amigo, Vicente [1 ]
机构
[1] Univ Politecn Valencia, Inst Tecnol Mat, Camino Vera S-N,5E Bldg, E-46022 Valencia, Spain
[2] Ecole Polytech Fed Lausanne, SCI STI SM, Tribol & Interface Chem Grp, Stn 12, CH-1015 Lausanne, Switzerland
关键词
Ti6A14V ELI; Nanotubes; Corrosion; EIS; Surface treatments; MECHANICAL-PROPERTIES; TITANIUM; OXIDE; ALLOY; BIOACTIVITY; ARRAYS; BIOCOMPATIBILITY; BIOMATERIALS; ANODIZATION; RESISTANCE;
D O I
10.1016/j.jmrt.2019.09.023
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Surfaces engineering on titanium biomedical alloys aiming for improving bone regeneration, healing periods and increasing lifetime needs fora fundamental understanding of the electrochemical reactions occurring at the interface biomaterial/human fluid. There, electrochemical corrosion plays an important role in implant-tissue interaction. The aim of this study is to investigate the effect of different TiO2 surfaces and nanotubes on a Ti6Al4V ELI in their electrochemical corrosion resistance by different electrochemical techniques (open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic polarization). The electrochemical behaviour of native, anodized, nanotubular and annealed nanotubular surfaces were investigated in 1 M NaCl solution. The nanotubular topography was obtained by electrochemical oxidation and the annealing treatment allowed at changing the crystalline structure of the oxides. The nanotube morphology, chemical composition, and structure was studied by Field Emission Scanning Electron Microscopy, Energy Dispersive Spectroscopy, X-ray diffraction and Transmission Electron Microscopy respectively. The results show that the anodic oxidation treatment creates a nanotubular topography that increases the surface area and changes the surface chemical composition. The electrochemical corrosion resistance decreased on the as-formed TiO2 tubes compared to the native oxide layer, due to higher surface area and amorphous crystal structure of the passive film. After annealing treatment, the fluoride ions are eliminated, and nanotubular resistance is enhanced through anatase stabilization. (C) 2019 The Authors. Published by Elsevier B.V.
引用
收藏
页码:5548 / 5556
页数:9
相关论文
共 50 条
  • [1] TIG WELDING OF Ti6A14V: EFFECT OF Ti6A14V ELI As FILLER METAL
    Omoniyi, P. O.
    Mahamood, R. M.
    Adeleke, A. A.
    Ikubanni, P. P.
    Akinlabi, S. A.
    Akinlabi, E. T.
    ARCHIVES OF METALLURGY AND MATERIALS, 2023, 68 (02) : 769 - 773
  • [2] Topology optimization and characterization of Ti6A14V ELI cellular lattice structures by laser powder bed fusion for biomedical applications
    Vilardell, A. M.
    Takezawa, A.
    du Plessis, A.
    Takata, N.
    Krakhmalev, P.
    Kobashi, M.
    Yadroitsava, I.
    Yadroitsev, I.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2019, 766
  • [3] Laser surface deposition of niobium and titanium-niobium on Ti6A14V substrates for biomedical applications
    Pityana, S. L.
    Baloyi, N.
    Tlotleng, M.
    Popoola, P.
    JOURNAL OF THE SOUTHERN AFRICAN INSTITUTE OF MINING AND METALLURGY, 2019, 119 (04) : 385 - 389
  • [4] Depth distributions and wear behaviour of ion implanted Ti6A14V
    Schmidt, H
    Baumann, H
    Ruck, DM
    MATERIALS SCIENCE APPLICATIONS OF ION BEAM TECHNIQUES, 1997, 248-2 : 209 - 212
  • [5] Corrosion properties of TiN prepared by laser gas alloying of Ti and Ti6A14V
    Deptartment of Corros. and Protect., Ctro. Nac. de Invest. Metalurgicas, Avenida de Gregorio del Amo, 8, E-28040 Madrid, Spain
    Corros. Sci., 8 (1411-1419):
  • [6] Tribocorrosion behaviour of Ti6A14V in artificial seawater at low contact pressures
    Pejakovic, Vladimir
    Totolin, Vladimir
    Ripoll, Manel Rodriguez
    TRIBOLOGY INTERNATIONAL, 2018, 119 : 55 - 65
  • [7] A deep-sea corrosion study on titanium and Ti6A14V alloy
    Venkatesan, R
    Dwarakadasa, ES
    Ravindran, M
    CORROSION PREVENTION & CONTROL, 2004, 51 (03): : 98 - 103
  • [8] Ti6A14V的激光涂层
    李华伦
    Molian P.A.
    航空学报, 1990, (08) : 405 - 409
  • [9] Tribological behaviour of alumina sliding against Ti6A14V in unlubricated contact
    Dong, H
    Bell, T
    WEAR, 1999, 225 : 874 - 884
  • [10] Friction and wear behaviour of cp Ti and Ti6A14V following nitric acid passivation
    Masmoudi, M.
    Assoul, M.
    Wery, M.
    Abdelhedi, R.
    El Halouani, F.
    Monteil, G.
    APPLIED SURFACE SCIENCE, 2006, 253 (04) : 2237 - 2243