Radiobiologically Quantified Treatment Setup Uncertainties Based On Megavoltage (MV) CT Imaging

被引:0
|
作者
Swanson, G.
Shi, C.
Mavroidis, P.
Stathakis, S.
Su, F.
Ramer, R.
Sarkar, V.
Ferreira, B.
Komisopoulos, G.
Giantsoudi, D.
Papanikolaou, N.
机构
关键词
D O I
10.1118/1.2962173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-GG-T425
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Treatment setup uncertainties as quantified based on daily megavoltage (MV) CT imaging
    Shi, C.
    Stathakis, S.
    Ramer, C.
    Sarkar, V.
    Giantsoudi, D.
    Mavroidis, P.
    Papanikolaou, N.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S180 - S181
  • [2] TREATMENT SETUP UNCERTAINTIES QUANTIFIED BY MEGAVOLTAGE CT IMAGING
    Stathakis, S.
    Shi, C.
    Mavroidis, P.
    Swanson, G.
    Ramer, C.
    Sarkar, V.
    Ferreira, B. Costa
    Komisopoulos, G.
    Giantsoudi, D.
    Papanikolaou, N.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S437 - S437
  • [3] Use of megavoltage CT imaging for quantifying treatment setup uncertainties
    Stathakis, S.
    Shi, C.
    Mavroidis, P.
    Giantsoudi, D.
    Swanson, G.
    Esquivel, C.
    Ferreira, B. C.
    Komisopoulos, G.
    Papanikolaou, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S660 - S660
  • [4] Assessment of setup uncertainties for head-and-neck cancer patients using daily megavoltage CT imaging
    Duan, J.
    Spencer, S. A.
    Shen, S.
    De Los Santos, J. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S445 - S445
  • [5] Three-dimensional patient setup errors at different treatment sites measured by the Tomotherapy megavoltage CT
    Hui, S. K.
    Lusczek, E.
    DeFor, T.
    Dusenbery, K.
    Levitt, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (04) : 346 - 352
  • [6] MV CBCT based assessment of setup uncertainties and planning target volume margin in head and neck cancer
    Sikdar, Debanjan
    Krishnan, Ajay S.
    Namitha, Rs
    Chakravarty, Abhishek
    Gupta, Dhiraj
    Gupta, Sweety
    Kumar, Arvind
    Joseph, Deepa
    Gupta, Manoj
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2024, 29 (02) : 141 - 147
  • [7] Setup uncertainties in linear accelerator based stereotactic radiosurgery and a derivation of the corresponding setup margin for treatment planning
    Zhang, Mutian
    Zhang, Qinghui
    Gan, Hua
    Li, Sicong
    Zhou, Su-min
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 379 - 385
  • [8] ANALYSIS OF PATIENT SETUP UNCERTAINTIES BY USING IN-TREATMENT CONE-BEAM CT FOR PROSTATE CANCER
    Shiraishi, K.
    Haga, A.
    Katsutake, S.
    Saotome, N.
    Kida, S.
    Sakumi, A.
    Onoe, T.
    Yamamoto, K.
    Ohtomo, K.
    Keiichi, N.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S472 - S472
  • [9] Dosimetric Effects of Rotational Uncertainties in Fiducial-Based Treatment Setup for Pancreas SBRT
    Yang, W.
    Fraass, B. A.
    Yue, Y.
    Nissen, N.
    Sandler, H.
    Tuli, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S672 - S672
  • [10] Registration Accuracy of MR-Based Images to On-Board Megavoltage Cone-Beam CT for Brain Patient Setup
    Pinnaduwage, D. S.
    Chen, J.
    Descovich, M.
    Hwang, Ken-Ping
    Pouliot, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 101 - 102