Optimization of a High-resolution Collimator for a CdTe Detector: Monte Carlo Simulation Studies

被引:7
|
作者
Lee, Young-Jin [1 ]
Ryu, Hyun-Ju
Cho, Hyo-Min
Lee, Seung-Wan
Choi, Yu-Na
Kim, Hee-Joung
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
基金
新加坡国家研究基金会;
关键词
Photon counting detector; Collimator optimization; Pixelated parallel-hole collimator; GAMMA-CAMERA; SPECT; GATE; PERFORMANCE; PLATFORM; PET;
D O I
10.3938/jkps.60.862
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Photon counting detectors using cadmium zinc telluride (CZT) or cadmium telluride (CdTe) have benefits compared to conventional scintillation detectors, and CZT and CdTe have advantageous physical characteristics for nuclear medicine imaging. Recently, many studies have been conducted using these materials to improve the sensitivity and the spatial resolution of the photon counting detector. By using a pixelated parallel-hole collimator, we may be able to improve the sensitivity and the spatial resolution. The purpose of this study was to optimize the design of a collimator to achieve excellent resolution and high sensitivity for a gamma camera system based on the CdTe detector. In this study we simulated a gamma camera system with a photon counting detector based on CdTe and evaluated the system's performance. We performed a simulation study of the PID 350 (Ajat Oy Ltd., Finland) CdTe detector by using a Geant4 Application for Tomographic Emission (GATE) simulation. This detector consists of small pixels (0.35 x 0.35 mm(2)). We designed two parallel-hole collimators with different shapes and verified their usefulness. One was the proposed pixelated parallel-hole collimator in which the hole size and the pixel size are the same, and the other was the hexagonal parallel-hole collimator, which had a hole size similar to that of the pixelated parallel-hole collimator. We evaluated the sensitivity, spatial resolution, and contrast resolution to determine which parallel-hole collimator was best for the PID 350 CdTe detector. The average sensitivity was 22.65% higher for the pixelated parallel-hole collimator than for the hexagonal parallel-hole collimator. Also, the pixelated parallel-hole collimator provided 10.7% better spatial resolution than the hexagonal parallel-hole collimator, and the contrast resolution was improved by 8.93%. These results reflect an improvement in sensitivity and spatial resolution, and indicate that the imaging performance of the pixelated parallel-hole collimator is better than that of the hexagonal parallel-hole collimator. In conclusion, we successfully established a high resolution gamma camera system with a pixelated parallel-hole collimator, and based on our results, we recommend using the pixelated parallel-hole collimator to improve the sensitivity and the spatial resolution of gamma camera systems with semiconductor detectors such as CdTe.
引用
收藏
页码:862 / 868
页数:7
相关论文
共 50 条
  • [21] Monte-Carlo PET simulation with high-resolution anatomic template from BigBrain
    Funck, T.
    Evans, A. C.
    Thiel, A.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 : 140 - 141
  • [22] Monte Carlo Simulation of a Micro-multileaf Collimator
    Gonzalez, W.
    Lallena, A. M.
    Alfonso, R.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 1252 - +
  • [23] Analysis of scattered radiation cross-talk in a high-resolution gamma ray tomography detector with GATE Monte-Carlo simulation
    Kiessling, N.
    Bieberle, A.
    Hampel, U.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 595 (02): : 375 - 380
  • [24] The Monte Carlo simulation of the Borexino detector
    Agostini, M.
    Altenmueller, K.
    Appel, S.
    Atroshchenko, V.
    Bagdasarian, Z.
    Basilico, D.
    Bellini, G.
    Benziger, J.
    Bick, D.
    Bonfini, G.
    Borodikhina, L.
    Bravo, D.
    Caccianiga, B.
    Calaprice, F.
    Caminata, A.
    Canepa, M.
    Caprioli, S.
    Carlini, M.
    Cavalcante, P.
    Chepurnov, A.
    Choi, K.
    D'Angelo, D.
    Davini, S.
    Derbin, A.
    Ding, X. F.
    Di Noto, L.
    Drachnev, I.
    Fomenko, K.
    Formozov, A.
    Franco, D.
    Froborg, F.
    Gabriele, F.
    Galbiati, C.
    Ghiano, C.
    Giammarchi, M.
    Goeger-Neff, M.
    Goretti, A.
    Gromov, M.
    Hagner, C.
    Houdy, T.
    Hungerford, E.
    Ianni, Aldo
    Ianni, Andrea
    Jany, A.
    Jeschke, D.
    Kobychev, V.
    Korablev, D.
    Korga, G.
    Kryn, D.
    Laubenstein, M.
    ASTROPARTICLE PHYSICS, 2018, 97 : 136 - 159
  • [25] Monte Carlo Simulation of a CZT Detector
    Chun, Sung Dae
    Park, Se Hwan
    Ha, Jang Ho
    Kim, Han Soo
    Cho, Yoon Ho
    Kang, Sang Mook
    Kim, Yong Kyun
    Hong, Duk Geun
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 549 - 552
  • [26] Monte carlo simulation study of a novel parallel-hole collimator with a CdTe pixelated semiconductor SPECT system
    Lee, Young-Jin
    Kim, Dae-Hong
    Rhee, Yong-Chun
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (11) : 1737 - 1744
  • [27] Monte carlo simulation study of a novel parallel-hole collimator with a CdTe pixelated semiconductor SPECT system
    Young-Jin Lee
    Dae-Hong Kim
    Yong-Chun Rhee
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2014, 64 : 1737 - 1744
  • [28] FlexiSPECT: A compact SPECT system with a lofthole collimator and a high-resolution scintillation detector
    Deprez, Karel
    Van Holen, Roel
    Vandeghinste, Bert
    Vandenberghe, Stefaan
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [29] Characterization of scatter factors in thyroid studies using a pinhole collimator by Monte Carlo Simulation
    Rodriguez, S.
    Lopez, A.
    Diaz, A.
    Palau, A.
    Martin, J. M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 181 - 186
  • [30] OPTIMIZATION OF A PINHOLE COLLIMATOR IN A SPECT SCINTILLATING-FIBER DETECTOR SYSTEM - A MONTE-CARLO ANALYSIS
    HADEMENOS, GJ
    RADIATION PHYSICS AND CHEMISTRY, 1994, 43 (04): : 383 - 392