Optimization of a High-resolution Collimator for a CdTe Detector: Monte Carlo Simulation Studies

被引:7
|
作者
Lee, Young-Jin [1 ]
Ryu, Hyun-Ju
Cho, Hyo-Min
Lee, Seung-Wan
Choi, Yu-Na
Kim, Hee-Joung
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju 220710, South Korea
基金
新加坡国家研究基金会;
关键词
Photon counting detector; Collimator optimization; Pixelated parallel-hole collimator; GAMMA-CAMERA; SPECT; GATE; PERFORMANCE; PLATFORM; PET;
D O I
10.3938/jkps.60.862
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Photon counting detectors using cadmium zinc telluride (CZT) or cadmium telluride (CdTe) have benefits compared to conventional scintillation detectors, and CZT and CdTe have advantageous physical characteristics for nuclear medicine imaging. Recently, many studies have been conducted using these materials to improve the sensitivity and the spatial resolution of the photon counting detector. By using a pixelated parallel-hole collimator, we may be able to improve the sensitivity and the spatial resolution. The purpose of this study was to optimize the design of a collimator to achieve excellent resolution and high sensitivity for a gamma camera system based on the CdTe detector. In this study we simulated a gamma camera system with a photon counting detector based on CdTe and evaluated the system's performance. We performed a simulation study of the PID 350 (Ajat Oy Ltd., Finland) CdTe detector by using a Geant4 Application for Tomographic Emission (GATE) simulation. This detector consists of small pixels (0.35 x 0.35 mm(2)). We designed two parallel-hole collimators with different shapes and verified their usefulness. One was the proposed pixelated parallel-hole collimator in which the hole size and the pixel size are the same, and the other was the hexagonal parallel-hole collimator, which had a hole size similar to that of the pixelated parallel-hole collimator. We evaluated the sensitivity, spatial resolution, and contrast resolution to determine which parallel-hole collimator was best for the PID 350 CdTe detector. The average sensitivity was 22.65% higher for the pixelated parallel-hole collimator than for the hexagonal parallel-hole collimator. Also, the pixelated parallel-hole collimator provided 10.7% better spatial resolution than the hexagonal parallel-hole collimator, and the contrast resolution was improved by 8.93%. These results reflect an improvement in sensitivity and spatial resolution, and indicate that the imaging performance of the pixelated parallel-hole collimator is better than that of the hexagonal parallel-hole collimator. In conclusion, we successfully established a high resolution gamma camera system with a pixelated parallel-hole collimator, and based on our results, we recommend using the pixelated parallel-hole collimator to improve the sensitivity and the spatial resolution of gamma camera systems with semiconductor detectors such as CdTe.
引用
收藏
页码:862 / 868
页数:7
相关论文
共 50 条
  • [1] Optimization of a high-resolution collimator for a CdTe detector: Monte Carlo simulation studies
    Young-Jin Lee
    Hyun-Ju Ryu
    Hyo-Min Cho
    Seung-Wan Lee
    Yu-Na Choi
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2012, 60 : 862 - 868
  • [2] Optimization of high resolution collimator with CdTe detector : a simulation study
    Lee, Young-Jin
    Kim, Hee-Joung
    Ryu, Hyun-Ju
    Cho, Hyo-Min
    Lee, Seung-Wan
    Choi, Yu-Na
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [3] A Monte Carlo simulation study of the feasibility of a high resolution parallel-hole collimator with a CdTe pixelated semiconductor SPECT system
    Lee, Y. -J.
    Park, S. -J.
    Lee, S. -W.
    Kim, D. -H.
    Kim, Y. -S.
    Jo, B. -D.
    Kim, H. -J.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [4] HIGH-RESOLUTION CDTE DETECTOR SYSTEMS
    REDUS, R
    SQUILLANTE, M
    LUND, J
    CIRIGNANO, L
    WAER, P
    PANTAZIS, J
    HUBER, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 59 - 59
  • [5] The Effect of High-resolution Parallel-hole Collimator Materials with a Pixelated Semiconductor SPECT System at Equivalent Sensitivities: Monte Carlo Simulation Studies
    Lee, Young-Jin
    Kim, Dae-Hong
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (07) : 1055 - 1062
  • [6] The effect of high-resolution parallel-hole collimator materials with a pixelated semiconductor SPECT system at equivalent sensitivities: Monte Carlo simulation studies
    Young-Jin Lee
    Dae-Hong Kim
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2014, 64 : 1055 - 1062
  • [7] Monte Carlo simulation of scintillation photons for the design of a high-resolution SPECT detector dedicated to human brain
    Hirano, Yoshiyuki
    Zeniya, Tsutomu
    Iida, Hidehiro
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (03) : 214 - 221
  • [8] Monte Carlo simulation of scintillation photons for the design of a high-resolution SPECT detector dedicated to human brain
    Yoshiyuki Hirano
    Tsutomu Zeniya
    Hidehiro Iida
    Annals of Nuclear Medicine, 2012, 26 : 214 - 221
  • [9] Monte Carlo Simulation and Collimator Optimization for Tomographic Gamma Scanning
    Zhang, Jinzhao
    Tuo, Xianguo
    Wang, Qibiao
    Leng, Yangchun
    Shi, Rui
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [10] High-resolution Schottky CdTe diode detector
    Takahashi, T
    Mitani, T
    Kobayashi, Y
    Kouda, M
    Sato, G
    Watanabe, S
    Nakazawa, K
    Okada, Y
    Funaki, M
    Ohno, R
    Mori, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 1297 - 1303