Speciation of inorganic arsenic in alimentary and environmental aqueous samples by using derivative anodic stripping chronopotentiometry (dASCP)

被引:34
作者
Dugo, G
La Pera, L
Lo Turco, V
Di Bella, G
机构
[1] Univ Messina, Dept Organ & Biol Chem, I-98166 Messina, Italy
[2] Univ Messina, Dept Vet Publ Hlth, I-98165 Messina, Italy
关键词
arsenic; beverages; gold film electrode; seawater; stripping chronopotentiometry;
D O I
10.1016/j.chemosphere.2005.03.049
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this research was to develop a sensitive and accurate chronopotentiometric method at a gold film electrode, to determine trace and ultra trace levels of As(III) and As(V) in alimentary and environmental water systems. As(III) was directly determined in the aqueous matrix at a deposition potential of -300 mV for 180 s and at a constant anodic current of 2.5 mu A, without any sample pre-treatment; moreover the chronopotentiometric method did not require a time-consuming de-oxygenation step prior to the analysis. A 3 M HCl solution was chosen as the best stripping medium. The direct analysis of As(V) required the application of a high negative over-potential and, thus, measurements were characterized by poor reproducibility; therefore As(V) was determined after reduction to As(III) with KI in a strong hydrochloric acid solution. Under the optimised electrochemical conditions, detection limits of 0.08 mu g As(III) l(-1) were achieved and no significant interferences from Cd, Cu, Pb, Zn and organic substances were observed. As(V) was the most abundant species in all the studied environmental and alimentary aqueous matrices. Amongst the beverages, tea and coffee presented the As(V) highest concentration ranges (934-1740 mu g l(-1) and 850-1290 mu g l(-1), respectively) while bottled mineral water the lowest (< 1.61 mu g l(-1)); whereas As(III) levels lower than 5.0 mu g l(-1) were detected only in wine samples. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1093 / 1101
页数:9
相关论文
共 27 条
[1]   Constant current cathodic stripping potentiometric determination of arsenic on a mercury film electrode in the presence of copper ions [J].
Adeloju, SB ;
Young, TM ;
Jagner, D ;
Batley, GE .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :207-213
[2]  
Bard A.J., 2001, ELECTROCHEMICAL METH, pp148
[3]  
Biswas BK, 1998, CURR SCI INDIA, V74, P134
[4]   Determination of arsenic species in seawater by flow injection hydride generation in situ collection followed by graphite furnace atomic absorption spectrometry - Stability of As(III) [J].
Cabon, JY ;
Cabon, N .
ANALYTICA CHIMICA ACTA, 2000, 418 (01) :19-31
[5]   Detection: International update, and some emerging di-lemmas involving calibration, the blank, and multiple detection decisions [J].
Currie, LA .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 37 (01) :151-181
[6]  
DRUGO G, 2004, J AGR FOOD CHEM, V52, P1835
[7]   Determination of Cd(II), Cu(II), Pb(II), and Zn(II) content in commercial vegetable oils using derivative potentiometric stripping analysis [J].
Dugo, G ;
La Pera, L ;
La Torre, GL ;
Giuffrida, D .
FOOD CHEMISTRY, 2004, 87 (04) :639-645
[8]  
DUGO G, 2004, MED C CHEM AQ SYST 4
[9]   Off-line separation and determination of inorganic arsenic species in natural water by high resolution inductively coupled plasma mass spectrometry with hydride generation combined with reaction of arsenic(V) and L-cysteine [J].
Feng, YL ;
Chen, HY ;
Tian, LC ;
Narasaki, H .
ANALYTICA CHIMICA ACTA, 1998, 375 (1-2) :167-175
[10]  
GAUTAM S, 1999, MICROCHEM J, V62, P174