Ferrofluid plug as valve and actuator for whole-cell PCR on chip

被引:21
作者
Lok, Khoi Seng [1 ]
Kwok, Yien Chian [1 ]
Lee, Peter Peng Foo [1 ]
Nguyen, Nam-Trung [2 ]
机构
[1] Nanyang Technol Univ, Natl Inst Educ, Singapore 637616, Singapore
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2012年 / 166卷
关键词
Whole-cell PCR; Magnetically actuated; PCR microchip; Lab-on-a-chip; Ferrofluid; DNA SAMPLE PREPARATION; MICROCHIP; AMPLIFICATION;
D O I
10.1016/j.snb.2012.03.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ferrofluid plug was first used as valve and actuator to circumvent the evaporation of aqueous fluid in LOC. Moreover, this dynamic plug catered for aqueous fluid expansion during its heating in the microchannel. Whole-cell polymerase chain reaction (PCR) protocol was successfully implemented in a magnetically actuated closed-loop PCR microchip system. Here, the ferrofluid plug was used to reduce the evaporation of the PCR sample in the thermal lysis step. A whole-cell PCR model was used to demonstrate this concept. The DNA plasmid, pUC19, was transformed into DH5 alpha competent cells. Primer pairs were designed to amplify region of interest in pUC19. The transformants were cultured and selected. Whole-cell PCR was performed on intact bacteria to screen for the presence of pUC19, containing the region of interests. Serial dilutions demonstrated the limit of detection for this system to be four bacterial cells. PCR amplifications were verified with regular thermocyclers and results were comparable. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:893 / 897
页数:5
相关论文
共 21 条
  • [1] Ferrofluid-based microchip pump and valve
    Hartshorne, H
    Backhouse, CJ
    Lee, WE
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (2-3): : 592 - 600
  • [2] A ferrofluidic magnetic micropump
    Hatch, A
    Kamholz, AE
    Holman, G
    Yager, P
    Böhringer, KF
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2001, 10 (02) : 215 - 221
  • [3] Bacterial DNA sample preparation from whole blood using surface-modified Si pillar arrays
    Hwang, Kyu-Youn
    Lim, Hee-Kyun
    Jung, Seong-Young
    Namkoong, Kak
    Kim, Joon-Ho
    Huh, Nam
    Ko, Christopher
    Park, Jae-Chan
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (20) : 7786 - 7791
  • [4] Rapid detection of bacterial cell from whole blood: Integration of DNA sample preparation into single micro-PCR chip
    Hwang, Kyu-Youn
    Jeong, Sung-Young
    Kim, Young-Rok
    Namkoong, Kak
    Lim, Hee-Kyun
    Chung, Won-Seok
    Kim, Joon-Ho
    Huh, Nam
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 154 (01) : 46 - 51
  • [5] Ferrofluid mediated nanocytometry
    Kose, Ayse Rezzan
    Koser, Hur
    [J]. LAB ON A CHIP, 2012, 12 (01) : 190 - 196
  • [6] Microchip PCR
    Kricka, LJ
    Wilding, P
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (05) : 820 - 825
  • [7] Integrated portable genetic analysis microsystem for pathogen/infectious disease detection
    Lagally, ET
    Scherer, JR
    Blazej, RG
    Toriello, NM
    Diep, BA
    Ramchandani, M
    Sensabaugh, GF
    Riley, LW
    Mathies, RA
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (11) : 3162 - 3170
  • [8] Lok K.S., 2012, MICROCHIMICA ACTA, V1-7
  • [9] Sample loading and retrieval by centrifugation in a closed-loop PCR microchip
    Lok, Khoi Seng
    Kwok, Yien Chian
    Nguyen, Nam-Trung
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 445 - 453
  • [10] Towards ferrofluidics for μ-TAS and lab on-a-chip applications
    Mao, LD
    Koser, H
    [J]. NANOTECHNOLOGY, 2006, 17 (04) : S34 - S47