Coincidence detection FDG PET in the management of oncological patients: attenuation correction versus non-attenuation correction

被引:6
|
作者
Chan, WL [1 ]
Freund, J [1 ]
Pocock, NA [1 ]
Szeto, E [1 ]
Chan, F [1 ]
Sorensen, BJ [1 ]
McBride, B [1 ]
机构
[1] St Vincents Hosp, Dept Nucl Med, Sydney, NSW, Australia
关键词
fluorodeoxyglucose; Co-PET; attenuation correction; neoplasm;
D O I
10.1097/00006231-200111000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to determine if attenuation correction (AC) in a dual-head, coincidence, positron emission tomography imaging system (Co-PET) improved image quality, lesion detection, patient staging and management of various malignant neoplasms, compared to non-attenuation corrected (NAC) images. Thirty patients with known or suspected malignant neoplasms underwent fluorodeoxyglucose (FDG) Co-PET, which was correlated with histopathology, computed tomography (CT) and other conventional imaging modalities and clinical follow-up. The number and location of FDG avid lesions detected on the AC images and NAC Co-PET images were blindly assessed by two independent observers. Semi-quantitative grading of image clarity and lesion-to-background quality was performed. This revealed markedly improved image clarity and lesion-to-background quality in the AC versus NAC Co-PET images. AC Co-PET was statistically superior to NAC Co-PET in relation to lesion detection (P < 0.01) and tumour staging (P < 0.01). NAC Co-PET demonstrated 51 of the 65 lesions (78%) detected by AC Co-PET. AC Co-PET altered tumour staging in five additional patients (16%) compared to NAC Co-PET. Management was altered in two of these five patients. ((C) 2001 Lippincott Williams & Wilkins).
引用
收藏
页码:1185 / 1192
页数:8
相关论文
共 50 条
  • [41] ZTE MR-based attenuation correction in brain FDG-PET/MR: performance in patients with cognitive impairment
    Brian Sgard
    Maya Khalifé
    Arthur Bouchut
    Brice Fernandez
    Marine Soret
    Alain Giron
    Clara Zaslavsky
    Gaspar Delso
    Marie-Odile Habert
    Aurélie Kas
    European Radiology, 2020, 30 : 1770 - 1779
  • [42] Automated PET/CT Brain Registration for Accurate Attenuation Correction
    Khurshid, Khawar
    Berger, Kevin L.
    McGough, Robert J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5805 - 5808
  • [43] ACCURATE ATTENUATION CORRECTION DESPITE MOVEMENT DURING PET IMAGING
    ANDERSSON, JLR
    VAGNHAMMAR, BE
    SCHNEIDER, H
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (04) : 670 - 678
  • [44] Automated PET attenuation correction model for functional brain imaging
    Weinzapfel, BT
    Hutchins, GD
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (03) : 483 - 491
  • [45] Importance of Attenuation Correction (AC) for Small Animal PET Imaging
    El Ali, Henrik H.
    Bodholdt, Rasmus Poul
    Jorgensen, Jesper Tranekjr
    Myschetzky, Rebecca
    Kjaer, Andreas
    DIAGNOSTICS, 2012, 2 (04) : 42 - 51
  • [46] Dose optimization: a review of CT imaging for PET attenuation correction
    Samuel L. Brady
    Barry L. Shulkin
    Clinical and Translational Imaging, 2017, 5 : 359 - 371
  • [47] Attenuation Correction Approaches for Serotonin Transporter Quantification With PET/MRI
    Rischka, Lucas
    Gryglewski, Gregor
    Berroteran-Infante, Neydher
    Rausch, Ivo
    James, Gregory Miles
    Kloebl, Manfred
    Sigurdardottir, Helen
    Hartenbach, Markus
    Hahn, Andreas
    Wadsak, Wolfgang
    Mitterhauser, Markus
    Beyer, Thomas
    Kasper, Siegfried
    Prayer, Daniela
    Hacker, Marcus
    Lanzenberger, Rupert
    FRONTIERS IN PHYSIOLOGY, 2019, 10
  • [48] Attenuation correction for the NIH ATLAS small animal PET scanner
    Yao, RT
    Seidel, J
    Liow, JS
    Green, MV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 664 - 668
  • [49] Automated PET/CT cardiac registration for accurate attenuation correction
    Khurshid, Khawar
    Wu, Liyong
    Berger, Kevin
    McGough, Robert J.
    2006 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY, 2006, : 409 - 414
  • [50] Attenuation correction for phantom tests: an alternative to maximum-likelihood attenuation correction factor-based correction for clinical studies in time-of-flight PET
    Tetsuro Mizuta
    Yoshiyuki Yamakawa
    Suzuka Minagawa
    Tetsuya Kobayashi
    Atsushi Ohtani
    Shiho Takenouchi
    Kohei Hanaoka
    Shota Watanabe
    Daisuke Morimoto-Ishikawa
    Takahiro Yamada
    Hayato Kaida
    Kazunari Ishii
    Annals of Nuclear Medicine, 2022, 36 : 998 - 1006