Rapid C-reactive protein determination in whole blood with a White Light Reflectance Spectroscopy label-free immunosensor for Point-of-Care applications

被引:17
|
作者
Koukouvinos, Georgios [1 ]
Goustouridis, Dimitrios [2 ,3 ]
Misiakos, Konstantinos [4 ]
Kakabakos, Sotirios [1 ]
Raptis, Ioannis [2 ,4 ]
Petrou, Panagiota [1 ]
机构
[1] NCSR Demokritos, Inst Nucl & Radiol Sci & Technol Energy & Safety, Immunoassay Immunosensors Lab, Aghia Paraskevi 15310, Greece
[2] ThetaMetrisis SA, Egaleo 12243, Greece
[3] TEI Piraeus, Dept Elect Engn, Egaleo 12244, Greece
[4] NCSR Demokritos, Inst Nanosci & Nanotechnol, Opt Sensors Lab, Aghia Paraskevi 15310, Greece
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2018年 / 260卷
关键词
White light reflectance spectroscopy; C-reactive protein; Whole blood; Fast assay; SENSITIVE DETECTION; D-DIMER; IMMOBILIZATION; INFLAMMATION; BIOSENSOR; DISEASE; MARKERS; CRP; ANTIBODY; SAMPLES;
D O I
10.1016/j.snb.2018.01.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The fast and accurate determination of C-reactive protein (CRP) in human whole blood samples employing a white light reflectance spectroscopy sensing platform is demonstrated. Each assay cycle was completed in 12 min, including 5-min reaction with the diluted whole blood samples, 3-min with the biotinylated anti-CRP antibody, and 4-min with streptavidin solution. The effect of whole blood on the assay performance was evaluated, and it was found that dilutions as low as 50-times could be employed. Thus, taking into account that the assay had a detection limit of 2.2 mu g/L CRP in 50-times diluted sample, whole blood concentrations as low as 110 mu g/L could be determined. In addition, due to the implementation of a two-step sandwich immunoassay, high-dose hook-effect was avoided. The accuracy of the assay was determined through recovery experiments by spiking whole blood samples with exogenous CRP. Mean recovery values ranging from 92 to 108% were obtained, indicating the accuracy of measurements performed with the developed immunosensor. The excellent analytical characteristics, the short analysis time and the compact instrument size support the applicability of the immunosensor developed for point-of-care CRP determinations. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:282 / 288
页数:7
相关论文
共 22 条
  • [11] A label-free flow-through immunosensor for determination of total- and free-PSA in human serum samples based on white-light reflectance spectroscopy
    Koukouvinos, G.
    Petrou, P. S.
    Misiakos, K.
    Drygiannakis, D.
    Raptis, I.
    Goustouridis, D.
    Kakabakos, S. E.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 1041 - 1048
  • [12] An array-based electrochemical magneto-immunosensor for early neonatal sepsis diagnostic: Fast and accurate determination of C-reactive protein in whole blood and plasma samples
    Molinero-Fernandez, Agueda
    Moreno-Guzman, Maria
    Lopez, Miguel angel
    Escarpa, Alberto
    MICROCHEMICAL JOURNAL, 2020, 157
  • [13] Rapid Microfluidic Immuno-Biosensor Detection System for the Point-of-Care Determination of High-Sensitivity Urinary C-Reactive Protein
    Chen, Szu-Jui
    Lu, Song-Yu
    Tseng, Chin-Chung
    Huang, Kuan-Hsun
    Chen, To-Lin
    Fu, Lung-Ming
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [14] Fast and Accurate Determination of Minute Ochratoxin A Levels in Cereal Flours and Wine with the Label-Free White Light Reflectance Spectroscopy Biosensing Platform
    Karachaliou, Chrysoula-Evangelia
    Koukouvinos, Georgios
    Zisis, Grigoris
    Kizis, Dimosthenis
    Krystalli, Evangelia
    Siragakis, George
    Goustouridis, Dimitris
    Kakabakos, Sotirios
    Petrou, Panagiota
    Livaniou, Evangelia
    Raptis, Ioannis
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [15] Label-free C-reactive protein electronic detection with an electrolyte-gated organic field-effect transistor-based immunosensor
    Maria Magliulo
    Donato De Tullio
    Inger Vikholm-Lundin
    Willem M. Albers
    Tony Munter
    Kyriaki Manoli
    Gerardo Palazzo
    Luisa Torsi
    Analytical and Bioanalytical Chemistry, 2016, 408 : 3943 - 3952
  • [16] Point-of-care assessment of C-reactive protein and white blood cell count to identify bacterial aetiologies in malaria-negative paediatric fevers in Tanzania
    Hildenwall, Helena
    Muro, Florida
    Jansson, Jaqueline
    Mtove, George
    Reyburn, Hugh
    Amos, Ben
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2017, 22 (03) : 286 - 293
  • [17] Comparison between point-of-care testing from capillary samples and conventional laboratory testing from venous samples for white blood cells and C-reactive protein in a pediatric outpatient setting
    Kuniyoshi, Yasutaka
    Kimoto, Takeru
    Tokutake, Haruka
    Takahashi, Natsuki
    Kamura, Azusa
    Tashiro, Makoto
    JOURNAL OF GENERAL AND FAMILY MEDICINE, 2025, 26 (01): : 79 - 84
  • [18] Comparison Between the Horiba Microsemi Point-of-Care C-Reactive Protein and Full Blood Cell Analyzer and the Horiba Pentra 120 and Roche Cobas 6000
    Woolley, Timothy
    POINT OF CARE, 2014, 13 (02): : 66 - 69
  • [19] Optical Biosensor for Bacteremia detection from human blood samples at a label-free Liquid Crystal-Aqueous Interface: A Rapid and Point-of-Care approach
    Das, Sayani
    Barman, Partha
    Chakraborty, Ranadhir
    Upadhyay, Anuj
    Sagdeo, Archna
    Kula, Przemyslaw
    Das, Malay Kumar
    Roy, Susanta Sinha
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2025, 683 : 79 - 89
  • [20] Point-of-care self-testing for measuring total white blood cells and C-reactive protein - a pilot study for future home-monitoring of patients during antibiotic treatment at home
    Schousboe, Amalie
    Wiese, Lothar
    INFECTIOUS DISEASES, 2023, 55 (04) : 235 - 242