Anterior Pelvic Soft Tissue Thickness Influences Acetabular Cup Positioning with Imageless Navigation

被引:10
作者
Hohmann, Erik [1 ,2 ]
Bryant, Adam [3 ]
Tetsworth, Kevin [4 ,5 ]
机构
[1] CQ Univ, Musculoskeletal Res Unit, Rockhampton, Qld 4700, Australia
[2] Rockhampton Hosp, Dept Orthopaed Surg, Rockhampton, Qld, Australia
[3] Univ Melbourne, Fac Med, Ctr Hlth Exercise & Sports Med, Melbourne, Vic, Australia
[4] Univ Queensland, Royal Brisbane Hosp, Dept Orthopaed Surg, Herston, Qld, Australia
[5] Univ Queensland, Sch Med, Div Surg, Herston, Qld, Australia
关键词
imageless navigation; total hip arthroplasty; anterior soft tissues; TOTAL HIP-ARTHROPLASTY; COMPUTER NAVIGATION; COMPONENT; ACCURACY; SYSTEM; IMPLANTATION; REPLACEMENT; ORIENTATION; VALIDATION; ULTRASOUND;
D O I
10.1016/j.arth.2011.09.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to investigate acetabular component position after total hip arthroplasty correlating both version and inclination to anterior pelvic soft tissue thickness. Thirty patients with a mean age of 66.5 +/- 14 (28-87) years and an average body mass index of 30.04 +/- 4.6 were included. The same surgeon operated on all 30 patients, using an anterolateral approach in a supine position and an imageless navigation system. Postoperative assessment of cup inclination, cup anteversion, and soft tissue thickness was measured by an independent research associate using computed tomographic scans. Pearson's moment correlations did not reveal any significant relationships between body mass index, soft tissue thickness, final intraoperative, or postoperative cup position. Anterior soft tissue thickness had no significant effect on the accuracy of acetabular cup positioning.
引用
收藏
页码:945 / 952
页数:8
相关论文
共 31 条
[1]   Navigated cup implantation in hip arthroplasty A meta-analysis [J].
Beckmann, Johannes ;
Stengel, Dirk ;
Tingart, Markus ;
Goetz, Juergen ;
Grifka, Joachim ;
Luering, Christian .
ACTA ORTHOPAEDICA, 2009, 80 (05) :538-544
[2]   Poor accuracy of freehand cup positioning during total hip arthroplasty [J].
Bosker, B. H. ;
Verheyen, C. C. P. M. ;
Horstmann, W. G. ;
Tulp, N. J. A. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) :375-379
[3]   Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[4]   Computer navigation in total hip replacement: a meta-analysis [J].
Gandhi, Rajiv ;
Marchie, Anthony ;
Farrokhyar, Forough ;
Mahomed, Nizar .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) :593-597
[5]   Comparison of conventional versus computer-navigated acetabular component insertion [J].
Haaker, Rolf G. A. ;
Tiedjen, Kai ;
Ottersbach, Andreas ;
Rubenthaler, Frank ;
Stockheim, Marthin ;
Stiehl, James B. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (02) :151-159
[6]  
Harkess WJ, 1992, CAMPBELLS ORTHOPAEDI, P54
[7]  
HARRIS WH, 1980, CLIN ORTHOP RELAT R, P188
[8]   Accuracy of intraoperative assessment of acetabular prosthesis placement [J].
Hassan, DM ;
Johnston, GHF ;
Dust, WNC ;
Watson, G ;
Dolovich, AT .
JOURNAL OF ARTHROPLASTY, 1998, 13 (01) :80-84
[9]   Acetabular component orientation in intra- and postoperative positions in total hip arthroplasty [J].
Hayakawa, Keiko ;
Minoda, Yukihide ;
Aihara, Masaharu ;
Sakawa, Akira ;
Ohzono, Kenji ;
Tada, Koichi .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (09) :1151-1156
[10]   Navigated non-image-based positioning of the acetabulum during total hip replacement [J].
Jenny, Jean-Yves ;
Boeri, Cyril ;
Dosch, Jean-Claude ;
Uscatu, Marius ;
Ciobanu, Eugen .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) :83-87