Attenuation correction in PET using consistency conditions and a three-dimensional template

被引:19
作者
Bromiley, A [1 ]
Welch, A [1 ]
Chilcott, F [1 ]
Waikar, S [1 ]
McCallum, S [1 ]
Dodd, M [1 ]
Craib, S [1 ]
Schweiger, L [1 ]
Sharp, P [1 ]
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, Aberdeen AB24 2ZD, Scotland
关键词
attentuation; consistency conditions; correction misregistration; positron emission tomography (PET); radon transform;
D O I
10.1109/23.958358
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation correction is required in positron emission tomography for accurate quantitation and to reduce artifacts. In previous work, we have shown that consistency information can be used to perform attenuation correction in the absence of any transmission measurements. In the previous work, a separate object was used for each slice and was transformed in two dimensions. Here, we introduce an extension that performs three-dimensional transformations on a single object over many slices. The aim is to produce a useful attenuation correction in situations where either it is impractical to acquire transmission data or there is significant misregistration between the transmission and emission data. Results are presented for simulated test cases with uniform and nonuniform attenuation and experimental cardiac phantom data. The algorithm as it stands is too unstable to allow for accurate attenuation correction without any transmission measurements. However, it may be useful for correcting misregistration, and may possibly be extended to perform coregistration.
引用
收藏
页码:1371 / 1377
页数:7
相关论文
共 11 条
[1]  
[Anonymous], NUMERICAL RECIPES C
[2]  
Bengel FM, 1997, EUR J NUCL MED, V24, P1091
[3]  
Bleckmann C, 1999, J NUCL MED, V40, P2021
[4]  
HUANG SC, 1979, J COMPUT ASSIST TOMO, V3, P804
[5]  
Imran MB, 1998, J NUCL MED, V39, P1219
[6]   ATTENUATION CORRECTION IN POSITRON EMISSION TOMOGRAPHY [J].
NATTERER, F ;
HERZOG, H .
MATHEMATICAL METHODS IN THE APPLIED SCIENCES, 1992, 15 (05) :321-330
[7]   Oncologic diagnosis with 2-[fluorine-18]fluoro-2-deoxy-D-glucose imaging: Dual-head coincidence gamma camera versus positron emission tomographic scanner [J].
Shreve, PD ;
Steventon, RS ;
Deters, EC ;
Kison, PV ;
Gross, MD ;
Wahl, RL .
RADIOLOGY, 1998, 207 (02) :431-437
[8]   Basic imaging performance characteristics of a variable field of view PET camera using quadrant sharing detector design [J].
Uribe, J ;
Baghaei, H ;
Li, HD ;
Yokoyama, S ;
Zhang, N ;
Wang, JM ;
Dobbs, FR ;
Wong, WH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :491-497
[9]   Imaging of lung cancer with fluorine-18 fluorodeoxyglucose:: comparison of a dual-head gamma camera in coincidence mode with a full-ring positron emission tomography system [J].
Weber, WA ;
Neverve, J ;
Sklarek, J ;
Ziegler, SI ;
Bartenstein, P ;
King, B ;
Treumann, T ;
Enterrottacher, A ;
Krapf, M ;
Häussinger, KE ;
Lichte, H ;
Präuer, HW ;
Thetter, O ;
Schwaiger, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (04) :388-395
[10]   Attenuation correction in PET using consistency information [J].
Welch, A ;
Campbell, C ;
Clackdoyle, R ;
Natterer, F ;
Hudson, M ;
Bromiley, A ;
Mikecz, P ;
Chillcot, F ;
Dodd, M ;
Hopwood, P ;
Craib, S ;
Gullberg, GT ;
Sharp, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) :3134-3141