共 15 条
Sewer System Calibration for Smart Cities
被引:0
作者:
Ioan, Alexandra Georgiana
[1
,2
]
Anton, Anton
[1
]
Ioan, Alexandra Georgiana
[1
,2
]
机构:
[1] Tech Univ Civil Engn Bucharest, Hydraul & Environm Protect Dept, Bucharest, Romania
[2] Ramboll Denmark, Climate Adaptat & Green Infrastruct Dept, Orestad, Denmark
来源:
2017 8TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT (CIEM)
|
2017年
关键词:
sensitivity analysis;
calibration;
mathematical model;
CLIMATE-CHANGE;
MODEL SIMULATIONS;
URBAN DRAINAGE;
MANAGEMENT;
D O I:
暂无
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
The research presented here is introducing a modelling approach which investigates the influence of different runoff parameters that are used in the modelling process to achieve a suitable representation of the urban catchments runoff. The aim of this research is to analyse the calibration of a hydrological model in the area of Olsted, Denmark. Quantitative data such as rainfall, water level and flow were recorded during October 2016 - February 2017. A sensitivity analysis was made on three different runoff parameters. To compare the impact on the water level and flow recreated by the hydrodynamic model, different calibration scenarios were analysed. The errors in volume and peak were up to 10% and the correlation coefficient was in between 0,8-1 in more than 50% of the events. The sensitivity analysis showed a substantial difference of the water flow to the sewer system, emphasizing the necessity of uncertainty analysis of the hydrological models.
引用
收藏
页码:475 / 479
页数:5
相关论文