Observers design for uncertain Takagi-Sugeno systems with unmeasurable premise variables and unknown inputs. Application to a wastewater treatment plant

被引:56
作者
Kiss, A. M. Nagy [1 ]
Marx, B. [1 ]
Mourot, G. [1 ]
Schutz, G. [2 ]
Ragot, J. [1 ]
机构
[1] Nancy Univ, UMR 7039, Ctr Rech Automat Nancy, F-54516 Vandoeuvre Les Nancy, France
[2] Ctr Rech Publ Henri Tudor, LTI Unit Business & Syst Analyt, L-1855 Luxembourg, Luxembourg
关键词
Nonlinear systems; Model uncertainties; State estimation; Unknown input estimation; Unmeasurable premise variables; Linear matrix inequality; Wastewater treatment plant; IDENTIFICATION;
D O I
10.1016/j.jprocont.2011.05.001
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article aims the observer synthesis for uncertain nonlinear systems and affected by unknown inputs, represented under the multiple model (MM) formulation with unmeasurable premise variables. A proportional integral observer (PIO) is considered. In order to design such an observer, the nonlinear system is transformed into an equivalent MM form. The Lyapunov method, expressed through linear matrix inequality (LMI) formulation, is used to describe the stability analysis and for the observer synthesis. An application to a model of wastewater treatment plant (WWTP) is considered and the performances of the proposed approach are illustrated through numerical results. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1105 / 1114
页数:10
相关论文
共 38 条
[1]   Modified Gath-Geva fuzzy clustering for identification of Takagi-Sugeno fuzzy models [J].
Abonyi, J ;
Babuska, R ;
Szeifert, F .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART B-CYBERNETICS, 2002, 32 (05) :612-621
[2]  
Alex J., 1999, EUR CONTR C KARLSR G
[3]  
[Anonymous], 1994, STUDIES APPL NUMERIC
[4]  
[Anonymous], 1970, STOCHASTIC PROCESSES
[5]  
[Anonymous], THESIS TU EINDHOVEN
[6]   Observers for Takagi-Sugeno fuzzy systems [J].
Bergsten, P ;
Palm, R ;
Driankov, D .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART B-CYBERNETICS, 2002, 32 (01) :114-121
[7]   A nonlinear observer design for an activated sludge wastewater treatment process [J].
Boulkroune, B. ;
Darouach, M. ;
Zasadzinski, M. ;
Gille, S. ;
Fiorelli, D. .
JOURNAL OF PROCESS CONTROL, 2009, 19 (09) :1558-1565
[8]   Canonical observer forms for multi-output systems up to coordinate and output transformations in discrete time [J].
Califano, C. ;
Monaco, S. ;
Normand-Cyrot, D. .
AUTOMATICA, 2009, 45 (11) :2483-2490
[9]  
Chachuat B., 2003, Revue des Sciences de l'Eau, V16, P5
[10]  
CHACHUAT B, 2001, THESIS I NATL POLYTE