Calculation methods for ventricular diffusion-weighted imaging thermometry: phantom and volunteer studies

被引:32
作者
Sakai, Koji [1 ]
Yamada, Kei [2 ]
Sugimoto, Naozo
机构
[1] Kyoto Univ, Grad Sch Med, Dept Human Hlth Sci, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Prefectural Univ Med, Grad Sch Med Sci, Dept Radiol, Kyoto, Japan
关键词
MRI; brain; diffusion-weighted imaging; lateral ventricle; temperature; BRAIN TEMPERATURE;
D O I
10.1002/nbm.1755
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A method for the measurement of temperature in the lateral ventricle using diffusion-weighted imaging (DWI) has been proposed recently. This method uses predetermined arbitrary thresholds, but a more objective method of calculation would be useful. We therefore compared four different calculation methods, two of which were newly created and did not require predetermined thresholds. A rectangular polyethylene terephthalate bottle (8 x 10 x 28 cm(3)) was filled with heated water (35.0-38.8 degrees C) and used as a water phantom. The DWI data of 23 healthy subjects (aged 26-75years; mean +/- standard deviation, 50.13 +/- 19.1years) were used for this study. The temperature was calculated using the following equation: T(degrees C)=2256.74/ln(4.39221/D) +/- 273.15, where D is the diffusion coefficient. The mean ventricular temperature was calculated by four methods: two thresholding methods and two histogram curve-fitting methods. As a reference, we used the temperature measured at the tympanic membrane, which is known to be approximately 1 degrees C lower than the brain temperature. The averaged differences in temperature between mercury thermometry and classical predetermined thresholding methods for the water phantom were 0.10 +/- 0.42 and 0.05 +/- 0.41 degrees C, respectively. The histogram curve-fitting methods, however, yielded temperatures a little lower (averaged differences of -0.24 +/- 0.32 and -0.14 +/- 0.31 degrees C, respectively) than mercury thermometry. There was very little difference in temperature between tympanic thermometry and classical predetermined thresholding methods (+0.01 and -0.07 degrees C, respectively). In humans, however, the histogram curve-fitting methods yielded temperatures approximately 1 degrees C higher (+1.04 degrees C and +1.36 degrees C, respectively), suggesting that temperatures measured in this way more closely approximate the true brain temperature. The histogram curve-fitting methods were more objective and better matched the estimated brain temperature than did classical predetermined thresholding methods, although the standard deviation was wider in the former methods. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 14 条
[1]   Moderate increase in temperature may exacerbate neuroinflammatory processes in the brain: Human cell culture studies [J].
Bahniwal, Manpreet ;
Villanueva, Erika B. ;
Klegeris, Andis .
JOURNAL OF NEUROIMMUNOLOGY, 2011, 233 (1-2) :65-72
[2]  
Corbett RJT, 1999, AM J NEURORADIOL, V20, P1851
[3]   Intracerebral temperature in patients with hydrocephalus of varying aetiology [J].
Hirashima, Y ;
Takaba, M ;
Endo, S ;
Hayashi, N ;
Yamashita, K ;
Takaku, A .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1998, 64 (06) :792-794
[4]   Measurement of brain temperature with magnetic resonance spectroscopy in acute ischemic stroke [J].
Karaszewski, Bartosz ;
Wardlaw, Joanna M. ;
Marshall, Ian ;
Cvoro, Vera ;
Wartolowska, Karolina ;
Haga, Kristin ;
Armitage, Paul A. ;
Bastin, Mark E. ;
Dennis, Martin S. .
ANNALS OF NEUROLOGY, 2006, 60 (04) :438-446
[5]   Using diffusion MRI for measuring the temperature of cerebrospinal fluid within the lateral ventricles [J].
Kozak, L. R. ;
Bango, M. ;
Szabo, M. ;
Rudas, G. ;
Vidnyanszky, Z. ;
Nagy, Z. .
ACTA PAEDIATRICA, 2010, 99 (02) :237-243
[6]  
Kuroda Kagayaki, 2003, Magn Reson Med Sci, V2, P17, DOI 10.2463/mrms.2.17
[7]  
Mcilvoy Laura, 2004, J Neurosci Nurs, V36, P23
[8]   SELF-DIFFUSION IN NORMAL AND HEAVY-WATER IN RANGE 1-45 DEGREES [J].
MILLS, R .
JOURNAL OF PHYSICAL CHEMISTRY, 1973, 77 (05) :685-688
[9]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[10]  
2-S