共 43 条
Online in-situ monitoring of melt pool characteristic based on a single high-speed camera in laser powder bed fusion process
被引:29
作者:
Ma, Heng
[1
]
Mao, Zhuangzhuang
[1
]
Feng, Wei
[1
]
Yang, Yang
[2
]
Hao, Ce
[3
]
Zhou, Jiangfan
[4
]
Liu, Sheng
[5
]
Xie, Huimin
[6
]
Guo, Guangping
[2
]
Liu, Zhanwei
[1
]
机构:
[1] Beijing Inst Technol, Sch Aerosp Engn, Beijing 100081, Peoples R China
[2] AECC Beijing Inst Aeronaut Mat, Beijing 100095, Peoples R China
[3] AECC Commercial Aircraft Engine Co Ltd, Shanghai 200241, Peoples R China
[4] Beijing Inst Struct & Environm Engn, Beijing 100076, Peoples R China
[5] Wuhan Univ, Sch Power & Mech Engn, Wuhan 430072, Peoples R China
[6] Tsinghua Univ, Dept Engn Mech, AML, Beijing 100084, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Additive manufacturing;
Laser powder bed fusion;
Online in-situ monitoring;
Melt pool characteristic;
Temperature measurement;
RECOIL PRESSURE;
MICROSTRUCTURE;
TEMPERATURE;
PROFILE;
D O I:
10.1016/j.applthermaleng.2022.118515
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
In metal additive manufacturing (AM), the in-situ measurement of the melt pool characteristic plays a significant role in monitoring the quality of the printed components. In this work, based on dual-wavelength thermometry, a coaxial melt pool temperature measurement system with a single high-speed camera in the laser powder bed fusion (LPBF) process is developed, including the design of the relay and optical path amplification system, and the beam splitting and chromatic aberration correction system. Moreover, a dual-waveband image-matching method with sub-pixel accuracy, and an overall parameter calibration and optimization method are proposed to improve the accuracy of the coaxial temperature measurement system. Besides, the validation experiment measured by a high-temperature blackbody furnace and a standard photoelectric pyrometer indicates that the temperature measuring error of the developed system is less than 1%. The melt pool characteristics including the temperature distribution, profile, temperature gradient, and cooling rate were measured by the developed coaxial temperature measurement system, and the distribution of average temperature and peak temperature under different linear energy densities during single-line printing was also compared and analyzed. The single-line printing results of different parameters show that the higher the linear energy density, the higher the average temperature and peak temperature of the melt pool, and the optimized parameters minimize the fluctuation of melt pool temperature and are more favorable to the formation of high-quality parts. In multi-layer printing mode, the heat accumulation is strong, resulting in the slow cooling rate of the melt pool.
引用
收藏
页数:22
相关论文