Conducting triangular chambers for EMC measurements

被引:10
作者
Huang, Y [1 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
关键词
electromagnetic cavities; mode-stirred/reverberation chambers; electromagnetic compatibility (EMC) measurements;
D O I
10.1088/0957-0233/10/3/003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Conducting rectangular chambers have been used extensively for electromagnetic compatibility (EMC) shielding and measurement applications. In this communication, conducting triangular chambers are investigated as an alternative structure for rectangular EMC reverberation chambers, which are becoming an increasingly important and powerful tool for both radiated immunity and emission tests. A prime consideration of designing such a system is the total possible number of modes inside the chamber. A new approach is introduced to obtain this parameter for three different triangular chambers. The initial study has demonstrated that triangular chambers may offer better performance in some cases than their rectangular counterparts.
引用
收藏
页码:L21 / L24
页数:4
相关论文
共 5 条
[1]  
HAUNG Y, 1993, THESIS U OXFORD
[2]  
LIU BH, 1983, P IEEE INT S EMC WAS, P508
[3]   A REVIEW OF ELECTROMAGNETIC COMPATIBILITY INTERFERENCE MEASUREMENT METHODOLOGIES [J].
MA, MT ;
KANDA, M ;
CRAWFORD, ML ;
LARSEN, EB .
PROCEEDINGS OF THE IEEE, 1985, 73 (03) :388-411
[4]  
Mendes H. A., 1968, NEW APPROACH ELECTRO
[5]  
1997, P IEEE INT S EMC AUS