Automated ASPECT scoring in acute ischemic stroke: comparison of three software tools

被引:55
作者
Hoelter, Philip [1 ]
Muehlen, Iris [1 ]
Goelitz, Philipp [1 ]
Beuscher, Vanessa [2 ]
Schwab, Stefan [2 ]
Doerfler, Arnd [1 ]
机构
[1] Friedrich Alexander Univ FAU Erlangen Numberg, Dept Neuroradiol, Schwabachanlage 6, Erlangen 91054, Germany
[2] Friedrich Alexander Univ FAU Erlangen Numberg, Dept Neurol, Schwabachanlage 6, Erlangen 91054, Germany
关键词
Aspects; Software anylsis; Diagnostics; Acute ischemic stroke; EARLY CT SCORE; COMPUTED-TOMOGRAPHY SCORE; CEREBRAL-BLOOD-FLOW; ALBERTA STROKE; INFARCT CORE; RELIABILITY; THROMBECTOMY; PENUMBRA; SCANS;
D O I
10.1007/s00234-020-02439-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Various software applications offer support in the diagnosis of acute ischemic stroke (AIS), yet it remains unclear whether the performance of these tools is comparable to each other. Our study aimed to evaluate three fully automated software applications for Alberta Stroke Program Early CT (ASPECT) scoring (Syngo.via Frontier ASPECT Score Prototype V2, Brainomix e-ASPECTS (R) and RAPID ASPECTS) in AIS patients. Methods Retrospectively, 131 patients with large vessel occlusion (LVO) of the middle cerebral artery or the internal carotid artery, who underwent endovascular therapy (EVT), were included. Pre-interventional non-enhanced CT (NECT) datasets were assessed in random order using the automated ASPECT software and by three experienced neuroradiologists in consensus. Interclass correlation coefficient (ICC), Bland-Altman, and receiver operating characteristics (ROC) were applied for statistical analysis. Results Median ASPECTS of the expert consensus reading was 8 (7-10). Highest correlation was between the expert read and Brainomix (r = 0.871 (0.818, 0.909), p < 0.001). Correlation between expert read and Frontier V2 (r = 0.801 (0.719, 0.859), p < 0.001) and between expert read and RAPID (r = 0.777 (0.568, 0.871), p < 0.001) was high, respectively. There was a high correlation among the software tools (Frontier V2 and Brainomix: r = 0.830 (0.760, 0.880), p < 0.001; Frontier V2 and RAPID: r = 0.847 (0.693, 0.913), p < 0.001; Brainomix and RAPID: r = 0.835 (0.512, 0.923), p < 0.001). An ROC curve analysis revealed comparable accuracy between the applications and expert consensus reading (Brainomix: AUC = 0.759 (0.670-0.848), p < 0.001; Frontier V2: AUC = 0.752 (0.660-0.843), p < 0.001; RAPID: AUC = 0.734 (0.634-0.831), p < 0.001). Conclusion Overall, there is a convincing yet developable grade of agreement between current ASPECT software evaluation tools and expert evaluation with regard to ASPECT assessment in AIS.
引用
收藏
页码:1231 / 1238
页数:8
相关论文
共 37 条
[1]   STATISTICS AND ETHICS IN MEDICAL-RESEARCH .7. INTERPRETING RESULTS [J].
ALTMAN, DG .
BRITISH MEDICAL JOURNAL, 1980, 281 (6255) :1612-1614
[2]   Automated versus manual imaging assessment of early ischemic changes in acute stroke: comparison of two software packages and expert consensus [J].
Austein, Friederike ;
Wodarg, Fritz ;
Juergensen, Nora ;
Huhndorf, Monika ;
Meyne, Johannes ;
Lindner, Thomas ;
Jansen, Olav ;
Larsen, Naomi ;
Riedel, Christian .
EUROPEAN RADIOLOGY, 2019, 29 (11) :6285-6292
[3]   Time dependence of reliability of noncontrast computed tomography in comparison to computed tomography angiography source image in acute ischemic stroke [J].
Bal, Simerpreet ;
Bhatia, Rohit ;
Menon, Bijoy K. ;
Shobha, Nandavar ;
Puetz, Volker ;
Dzialowski, Imanuel ;
Modi, Jayesh ;
Goyal, Mayank ;
Hill, Michael D. ;
Smith, Eric E. ;
Demchuk, Andrew M. .
INTERNATIONAL JOURNAL OF STROKE, 2015, 10 (01) :55-60
[4]   Validity and reliability of a quantitative computed tomography score in predicting outcome of hyperacute stroke before thrombolytic therapy [J].
Barber, PA ;
Demchuk, AM ;
Zhang, JJ ;
Buchan, AM .
LANCET, 2000, 355 (9216) :1670-1674
[5]  
Bossuyt PM, 2015, BMJ-BRIT MED J, V351, DOI [10.1136/bmj.h5527, 10.1373/clinchem.2015.246280, 10.1148/radiol.2015151516]
[6]  
Broocks G, 2019, J NEUROINTERV
[7]   Cerebral Blood Flow Is the Optimal CT Perfusion Parameter for Assessing Infarct Core [J].
Campbell, Bruce C. V. ;
Christensen, Soren ;
Levi, Christopher R. ;
Desmond, Patricia M. ;
Donnan, Geoffrey A. ;
Davis, Stephen M. ;
Parsons, Mark W. .
STROKE, 2011, 42 (12) :3435-U180
[8]   A benchmarking tool to evaluate computer tomography perfusion infarct core predictions against a DWI standard [J].
Cereda, Carlo W. ;
Christensen, Soren ;
Campbell, Bruce C. V. ;
Mishra, Nishant K. ;
Mlynash, Michael ;
Levi, Christopher ;
Straka, Matus ;
Wintermark, Max ;
Bammer, Roland ;
Albers, Gregory W. ;
Parsons, Mark W. ;
Lansberg, Maarten G. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 (10) :1780-1789
[9]  
CICCHETTI DV, 1981, AM J MENT DEF, V86, P127
[10]   Machine Learning for Medical Imaging1 [J].
Erickson, Bradley J. ;
Korfiatis, Panagiotis ;
Akkus, Zeynettin ;
Kline, Timothy L. .
RADIOGRAPHICS, 2017, 37 (02) :505-515