Coronary stent patency: Dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom

被引:61
作者
Boll, Daniel T. [1 ]
Merkle, Elmar M. [1 ]
Paulson, Erik K. [1 ]
Fleiter, Thorsten R. [2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Univ Maryland, Med Ctr, Dept Radiol, Baltimore, MD 21201 USA
关键词
D O I
10.1148/radiol.2473070849
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively evaluate, by optimizing image acquisition and introducing alternative image postprocessing techniques, dual-energy multidetector computed tomography (CT) for depiction of the lumens of coronary artery stents placed in a moving anthropomorphic heart phantom. Materials and Methods: Four coronary stents (2, 3, 4, and 5 mm) were examined at 64-section dual-energy multidetector CT by using a dualdetector "double-decker" imager with stacked high- and low-energy detector arrays, 0.67-mm section thickness, and 32 x 0.625-mm collimation. Simultaneous high- and low-energy data sets were acquired at 80 and 140 kVp and at 400 mAs. Cardiac motion was simulated in a moving anthropomorphic heart phantom. Stents were imaged longitudinally and axially with the phantom at rest and with it in motion. Use of an enhancement algorithm based on high- and low-energy absorption profiles was proposed. Stent lumen depiction and stent mesh delineation were quantified in terms of contrast-to-noise ratio (CNR) and kurtosis (kappa), respectively. Image quality was analyzed at univariate general linear model analysis in which peak voltage and data enhancement algorithm were dependent factors and stent orientation and cardiac motion were independent factors. Results: Analysis of CNR and kappa revealed an interdependency between CNR and kappa and stent diameter: The CNR and kappa of smaller stents increased significantly when these stents were imaged at lower peak voltages in the axial plane and with the enhancement algorithm applied to the 80- kVp data sets (P < .001). The CNR and kappa of larger stents increased significantly when these stents were imaged at higher peak voltages in the longitudinal plane, and imaging of these stents benefited from the enhancement algorithm being applied to the 140-kVp data sets (P < .001). Conclusion: Dual-energy multidetector CT performed with optimized acquisition parameters and alternative image postprocessing led to enhanced coronary stent lumen depiction to an extent beyond that achieved with single-energy multidetector CT. (C) RSNA, 2008.
引用
收藏
页码:687 / 695
页数:9
相关论文
共 25 条
  • [1] Abramoff MD., 2004, Biophot. Int., V11, P36
  • [2] Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom
    Begemann, PGC
    van Stevendaal, U
    Manzke, R
    Stork, A
    Weiss, F
    Nolte-Ernsting, C
    Grass, M
    Adam, G
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (05) : 1015 - 1026
  • [3] Spectral coronary multidetector computed tomography angiography: Dual benefit by facilitating plaque characterization and enhancing lumen depiction
    Boll, Daniel T.
    Hoffmann, Martin H.
    Huber, Nadine
    Bossert, Andrea S.
    Aschoff, Andrik J.
    Fleiter, Thorsten R.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (05) : 804 - 811
  • [4] Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique
    Cademartiri, F
    Nieman, K
    van der Lugt, A
    Raaijmakers, RH
    Mollet, N
    Pattynama, PMT
    de Feyter, PJ
    Krestin, GP
    [J]. RADIOLOGY, 2004, 233 (03) : 817 - 823
  • [5] Carmi R, 2005, IEEE NUCL SCI CONF R, P1876
  • [6] Intercomparison of methods for image quality characterization. II. Noise power spectrum
    Dobbins, James T., III
    Samei, Ehsan
    T Ranger, Nicole
    Chen, Ying
    [J]. MEDICAL PHYSICS, 2006, 33 (05) : 1466 - 1475
  • [7] Performance of computed tomography for contrast agent concentration measurements with monochromatic x-ray beams:: comparison of K-edge versus temporal subtraction
    Elleaume, H
    Charvet, AM
    Corde, S
    Estéve, F
    Le Bas, JF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (18) : 3369 - 3385
  • [8] Coronary artery: Quantitative evaluation of normal diameter determined with electron-beam CT compared with cine coronary angiography - Initial experience
    Funabashi, N
    Kobayashi, Y
    Perlroth, M
    Rubin, GD
    [J]. RADIOLOGY, 2003, 226 (01) : 263 - 271
  • [9] Original report. Digital radiography with dual-energy subtraction: Improved evaluation of cardiac calcification.
    Gilkeson, RC
    Novak, RD
    Sachs, P
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) : 1233 - 1238
  • [10] MECHANISMS OF RESTENOSIS AND REDILATION WITHIN CORONARY STENTS - QUANTITATIVE ANGIOGRAPHIC ASSESSMENT
    GORDON, PC
    GIBSON, CM
    COHEN, DJ
    CARROZZA, JP
    KUNTZ, RE
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) : 1166 - 1174