Portable measurement device to quantitatively measure capillary refilling time

被引:3
作者
Shinozaki, Masayoshi [1 ]
Shimizu, Rika [1 ]
Saito, Daiki [2 ]
Nakada, Taka-aki [2 ]
Nakaguchi, Toshiya [3 ]
机构
[1] Chiba Univ, Grad Sch Sci & Engn, Dept Med Engn, Chiba, Japan
[2] Chiba Univ, Dept Emergency & Crit Care Med, Grad Sch Med, Chiba, Japan
[3] Chiba Univ, Ctr Frontier Med Engn, Chiba, Japan
关键词
Capillary refilling time; Peripheral circulation; Portable measurement device; Triage; TRIAGE;
D O I
10.1007/s10015-021-00723-w
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Capillary refilling time (CRT) is defined as the time taken for the distal capillary bed to regain its color after the capillaries have been blanched through external skin compression. Measuring the CRT is a simple method of evaluating peripheral circulation in the clinic. Typically, the CRT is measured by manually recording the time taken for the skin color to be regained after blanching using a timer. However, this method is observer-dependent, which results in variability and subjectivity. In this study, a portable CRT measurement device was developed for simple quantitative measurement. This device standardizes the operator's manual compression by measuring the manual compression force using a force sensor and displaying it as well as the duration of the compression on a display unit. The device also measures CRT by recording the change in skin color after fingertip compression using an RGB color sensor. The stability of CRT measurement by this device was compared with that of conventional CRT measurement, which involves manual compression and naked eye observation. These results showed that CRT measurement using this device was more stable than that by the conventional method. The proposed device can potentially improve the reliability of CRT measurement by reducing the variability in the manual compression force and ensuring accurate recording of the time.
引用
收藏
页码:48 / 57
页数:10
相关论文
共 41 条
  • [1] Capillary refill time exploration during septic shock
    Ait-Oufella, H.
    Bige, N.
    Boelle, P. Y.
    Pichereau, C.
    Alves, M.
    Bertinchamp, R.
    Baudel, J. L.
    Galbois, A.
    Maury, E.
    Guidet, B.
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 (07) : 958 - 964
  • [2] Capillary refill time in adults has poor inter-observer agreement
    Anderson, B.
    Kelly, A. M.
    Kerr, D.
    Jolley, D.
    [J]. HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2008, 15 (02) : 71 - 74
  • [3] Impact of patient and environmental factors on capillary refill time in adults
    Anderson, Bronwyn
    Kelly, Anne-Maree
    Kerr, Debra
    Clooney, Megan
    Jolley, Damien
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2008, 26 (01) : 62 - 65
  • [4] An automated quasi-continuous capillary refill timing device
    Blaxter, L. L.
    Morris, D. E.
    Crowe, J. A.
    Henry, C.
    Hill, S.
    Sharkey, D.
    Vyas, H.
    Hayes-Gill, B. R.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2016, 37 (01) : 83 - 99
  • [5] Canavan A, 2009, AM FAM PHYSICIAN, V80, P692
  • [6] Capillary refill time is a very useful clinical sign in early recognition and treatment of very sick children
    Carcillo, Joseph A.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2012, 13 (02) : 210 - 212
  • [7] Use of a Novel, Portable, LED-Based Capillary Refill Time Simulator within a Disaster Triage Context
    Chang, Todd P.
    Santillanes, Genevieve
    Claudius, Ilene
    Pham, Phung K.
    Koved, James
    Cheyne, John
    Gausche-Hill, Marianne
    Kaji, Amy H.
    Srinivasan, Saranya
    Donofrio, J. Joelle
    Bir, Cynthia
    [J]. PREHOSPITAL AND DISASTER MEDICINE, 2017, 32 (04) : 451 - 456
  • [8] de Souza RP, 2021, ARXIV210213611PHYS
  • [9] Espinoza Emilio Daniel Valenzuela, 2014, Rev Bras Ter Intensiva, V26, P269
  • [10] Capillary refill time in sick children: a clinical guide for general practice
    Fleming, Susannah
    Gill, Peter J.
    Van den Bruel, Ann
    Thompson, Matthew