Angle vs. LabSOCS for HPGe efficiency calibration

被引:9
|
作者
Stanic, Goran [1 ]
Nikolov, Jovana [1 ]
Tucakovic, Ivana [2 ]
Mrda, Dusan [1 ]
Todorovic, Natasa [1 ]
Grahek, Zeljko [2 ]
Coha, Ivana [2 ]
Vranicar, Andrei [1 ]
机构
[1] Univ Novi Sad, Fac Sci, Novi Sad, Serbia
[2] Rudjer Boskovic Inst, Zagreb, Croatia
关键词
Efficiency calibration; Angle; LabSOCS; Gamma spectrometry; ENVIRONMENTAL-SAMPLES; PEAK EFFICIENCY; GAMMA; SOFTWARE; DETECTOR; SIMULATION; EFFTRAN; ENERGY;
D O I
10.1016/j.nima.2018.12.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The quantitative determination of radionuclides by gamma ray spectrometry requires a high accuracy of detection efficiency determination. Different software codes for efficiency determination are available. The aim of this work was to compare different methods and software used for efficiency calibration modeling and analyses. For that purpose, same samples of vegetation and soil of known activities were measured using HPGe detectors in two laboratories which are employing different software for mathematical efficiency calibrations and analyses, LabSOCS which is based on purely mathematical calculations and Angle which uses a semi-empirical approach. The codes were also tested on samples with unknown reference values (different geometries and matrices). The main advantages and disadvantages of both software were compared. Both Angle and LabSOCS gave comparable and consistent results for different detectors, matrices and geometries used. Deviations of the order of 10% or less obtained from the comparison of different sets of parameters are acceptable and imply that Angle and LabSOCS can be considered reliable for gamma ray detector efficiency calibrations. The main limitation of LabSOCS is in its inability to be used on newly installed detectors (factory characterization needed first), as for Angle the main drawback is in its demand for reference materials which can be costly as well as the need for plenty detector characteristics which are not always provided by the manufacturer.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 50 条
  • [41] The first experimental test of the MEFFTRAN software on HPGe detector calibration for environmental samples
    Nikolic, Jelena Krneta
    Rajacic, Milica
    Todorovic, Dragana
    Vidmar, Tim
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 165 : 191 - 196
  • [42] Efficiency calibration of x-ray HPGe detectors for photons with energies above the Ge K binding energy
    Maidana, Nora L.
    Vanin, Vito R.
    Jahnke, Viktor
    Fernandez-Varea, Jose M.
    Martins, Marcos N.
    Brualla, Lorenzo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 371 - 380
  • [43] Full energy peak efficiency calibration of HPGe detector for point and extended sources using Monte Carlo code
    Agarwal, Chhavi
    Chaudhury, Sanhita
    Goswami, A.
    Gathibandhe, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (03) : 701 - 708
  • [44] Radionuclide-free efficiency calibration of an HPGe detector using monochromatic photon beams calibrated with a cryogenic radiometer
    Elvira, Victor H.
    Lepy, Marie-Christine
    Menesguen, Yves
    Melhem, Stephanie
    APPLIED RADIATION AND ISOTOPES, 2024, 203
  • [45] Study of true coincidence summing effects on FEP efficiency of HPGe detectors during decay measurements at HIRFL
    Zheng, Peng-Song
    Shi, Fu-Rong
    Dutt, Sunil
    Zhang, Ya-Ling
    Zhang, Yan-Shi
    Wang, Wei
    Li, Guang-Shun
    Wang, Si-Cheng
    Yang, Hao-Ran
    He, Jin-Qi
    Ma, Peng-Cong
    Gada, Jilehu
    Ma, Xin
    Zeng, Fan-Fei
    Huang, Hao
    Gao, Chen-Sheng
    Wang, Jian-Guo
    NUCLEAR SCIENCE AND TECHNIQUES, 2025, 36 (05)
  • [46] A new methodology for efficiency calibration of uncharacterized Ge detectors by using characterized Ge detectors
    Barba-Lobo, A.
    Exposito-Suarez, V. M.
    Suarez-Navarro, J. A.
    Bolivar, J. P.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 221
  • [47] Application of PHOTON simulation software on calibration of HPGe detectors
    Nikolic, J.
    Puzovic, J.
    Todorovic, D.
    Rajacic, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 799 : 159 - 165
  • [48] Determination of HPGe peak efficiency for voluminous gamma-ray sources by using an effective solid angle method
    Kang, M. Y.
    Sun, G. M.
    Kim, Junhyuck
    Choi, H. D.
    APPLIED RADIATION AND ISOTOPES, 2016, 116 : 69 - 76
  • [49] Optimisation design of cylindrical containers for improving the detection efficiency of a high-purity germanium detector using the LabSOCS
    Yang, Baolu
    Ha, Yiming
    Li, An
    Zhou, Hongjie
    Wang, Feng
    Li, Weiming
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 298 (03) : 1673 - 1677
  • [50] Empirical formula for the HPGe-detector efficiency dependence on energy and distance
    Pylypchynets, I.
    Lengyel, A.
    Parlag, O.
    Maslyuk, V.
    Potoki, I.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 319 (03) : 1315 - 1319