Angle vs. LabSOCS for HPGe efficiency calibration

被引:9
|
作者
Stanic, Goran [1 ]
Nikolov, Jovana [1 ]
Tucakovic, Ivana [2 ]
Mrda, Dusan [1 ]
Todorovic, Natasa [1 ]
Grahek, Zeljko [2 ]
Coha, Ivana [2 ]
Vranicar, Andrei [1 ]
机构
[1] Univ Novi Sad, Fac Sci, Novi Sad, Serbia
[2] Rudjer Boskovic Inst, Zagreb, Croatia
关键词
Efficiency calibration; Angle; LabSOCS; Gamma spectrometry; ENVIRONMENTAL-SAMPLES; PEAK EFFICIENCY; GAMMA; SOFTWARE; DETECTOR; SIMULATION; EFFTRAN; ENERGY;
D O I
10.1016/j.nima.2018.12.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The quantitative determination of radionuclides by gamma ray spectrometry requires a high accuracy of detection efficiency determination. Different software codes for efficiency determination are available. The aim of this work was to compare different methods and software used for efficiency calibration modeling and analyses. For that purpose, same samples of vegetation and soil of known activities were measured using HPGe detectors in two laboratories which are employing different software for mathematical efficiency calibrations and analyses, LabSOCS which is based on purely mathematical calculations and Angle which uses a semi-empirical approach. The codes were also tested on samples with unknown reference values (different geometries and matrices). The main advantages and disadvantages of both software were compared. Both Angle and LabSOCS gave comparable and consistent results for different detectors, matrices and geometries used. Deviations of the order of 10% or less obtained from the comparison of different sets of parameters are acceptable and imply that Angle and LabSOCS can be considered reliable for gamma ray detector efficiency calibrations. The main limitation of LabSOCS is in its inability to be used on newly installed detectors (factory characterization needed first), as for Angle the main drawback is in its demand for reference materials which can be costly as well as the need for plenty detector characteristics which are not always provided by the manufacturer.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 50 条
  • [31] A proposal to design a new high volume standard air filter for efficiency calibration of HPGe detector
    Tourang, Mahdi
    Hadadi, Asghar
    Athari Allaf, Mitra
    Sardari, Dariush
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 327 (01) : 345 - 352
  • [32] MODELING THE IMPACT OF UNCERTAINTY IN DETECTOR SPECIFICATION ON EFFICIENCY VALUES OF A HPGe DETECTOR USING ANGLE SOFTWARE
    Miller, Maurice
    Voutchkov, Mitko
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2013, 28 (02) : 169 - 181
  • [33] Efficiency transfer in the calibration of a coaxial p-type HpGe detector using the Monte Carlo method
    Vargas, MJ
    Díaz, NC
    Sánchez, DP
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (06) : 707 - 712
  • [34] Calibration of HPGe detectors using certified reference materials of natural origin
    Xhixha, Gerti
    Alberi, Matteo
    Baldoncini, Marica
    Bode, Kozeta
    Bylyku, Elida
    Cfarku, Florinda
    Callegari, Ivan
    Hasani, Fadil
    Landsberger, Sheldon
    Mantovani, Fabio
    Rodriguez, Eva
    Shala, Ferat
    Strati, Virginia
    Kaceli, Merita Xhixha
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (02) : 1507 - 1517
  • [35] EFFICIENCY CALIBRATION OF A WELL-TYPE HPGe DETECTOR USING EXPERIMENTAL AND MONTE CARLO SIMULATION TECHNIQUES
    Dalaka, Ekaterini
    Kuburas, Georgios
    Eleftheriadis, Konstantinos
    Anagnostakis, Marios J.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2020, 35 (02) : 121 - 129
  • [36] Efficiency calibration of a HPGe detector in the [46.54-2000] keV energy range for the measurement of environmental samples
    Daza, MJ
    Quintana, B
    García-Talavera, M
    Fernández, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (03) : 520 - 532
  • [37] Gamma ray registration efficiency simulation of a HPGe detector with PHITS
    Bagramova, A.
    Zhumadilov, K.
    Endo, S.
    Kajimoto, T.
    Sakaguchi, A.
    Zeinulla, Zh
    Hoshi, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025, 334 (01) : 381 - 387
  • [38] Experimentally determined vs. Monte Carlo simulated peak-to-valley ratios for a well-characterised n-type HPGe detector
    Ostlund, Karl
    Samuelsson, Christer
    Raaf, Christopher L.
    APPLIED RADIATION AND ISOTOPES, 2015, 95 : 94 - 100
  • [39] Characterization and representation of the HPGE detector efficiency
    Sparks, MH
    Griffin, PJ
    Flanders, TM
    Sallee, WW
    Vehar, DW
    REACTOR DOSIMETRY: RADIATION METROLOGY AND ASSESSMENT, 2001, 1398 : 706 - 713
  • [40] Urban energy efficiency: a breakthrough vs. the global crisis
    Pagani, Roberto
    TECHNE-JOURNAL OF TECHNOLOGY FOR ARCHITECTURE AND ENVIRONMENT, 2011, 1 : 54 - 61